Three-Dimensional Nonrigid MR-TRUS Registration Using Dual Optimization

被引:32
|
作者
Sun, Yue [1 ]
Yuan, Jing [1 ]
Qiu, Wu [1 ]
Rajchl, Martin [1 ]
Romagnoli, Cesare [2 ]
Fenster, Aaron [1 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Imaging, London, ON N6A 5K8, Canada
基金
加拿大健康研究院;
关键词
Convex optimization; magnetic resonance to transrectal ultrasound (MR-TRUS) prostate registration; modality independent neighborhood descriptor (MIND) similarity measurement; nonrigid image registration; GUIDED PROSTATE BIOPSY; IMAGE REGISTRATION; TRANSRECTAL ULTRASONOGRAPHY; RADICAL PROSTATECTOMY; CANCER; FLOW; SEGMENTATION; ACCURACY; MODEL;
D O I
10.1109/TMI.2014.2375207
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study, we proposed an efficient nonrigid magnetic resonance (MR) to transrectal ultrasound (TRUS) deformable registration method in order to improve the accuracy of targeting suspicious regions during a three dimensional (3-D) TRUS guided prostate biopsy. The proposed deformable registration approach employs the multi-channel modality independent neighborhood descriptor (MIND) as the local similarity feature across the two modalities of MR and TRUS, and a novel and efficient duality-based convex optimization-based algorithmic scheme was introduced to extract the deformations and align the two MIND descriptors. The registration accuracy was evaluated using 20 patient images by calculating the TRE using manually identified corresponding intrinsic fiducials in the whole gland and peripheral zone. Additional performance metrics [Dice similarity coefficient (DSC), mean absolute surface distance (MAD), and maximum absolute surface distance (MAXD)] were also calculated by comparing the MR and TRUS manually segmented prostate surfaces in the registered images. Experimental results showed that the proposed method yielded an overall median TRE of 1.76 mm. The results obtained in terms of DSC showed an average of 80.8 +/- 7.8% for the apex of the prostate, 92.0 +/- 3.4% for the mid-gland, 81.7 +/- 6.4% for the base and 85.7 +/- 4.7% for the whole gland. The surface distance calculations showed an overall average of 1.84 +/- 0.52 mm for MAD and 6.90 +/- 2.07 mm for MAXD.
引用
收藏
页码:1085 / 1095
页数:11
相关论文
共 50 条
  • [41] Registration and Optimization Algorithm of Key Points in Three-Dimensional Point Cloud
    Song Tao
    Cao Libo
    Zhao Mingfu
    Liu Shuai
    Luo Yuhang
    Yang Xin
    LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (04)
  • [42] Industrial Robot Pose Estimation Using Three-Dimensional Registration
    Xu, Haili
    Zhang, Xingguo
    Hua, Guoran
    Wang, Sun'an
    2009 7TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS, VOLS 1 AND 2, 2009, : 674 - +
  • [43] Three-dimensional image registration using distributed parallel computing
    Song, Huajun
    Qiu, Peihua
    IET IMAGE PROCESSING, 2018, 12 (10) : 1713 - 1720
  • [44] Automated two-dimensional-three-dimensional registration using intensity gradients for three-dimensional reconstruction
    Duraisamy, Prakash
    Belkhouche, Yassine
    Jackson, Stephen
    Namuduri, Kamesh
    Buckles, Bill
    JOURNAL OF APPLIED REMOTE SENSING, 2012, 6
  • [45] Learning Non-rigid Deformations for Robust, Constrained Point-based Registration in Image-Guided MR-TRUS Prostate Intervention
    Onofrey, John A.
    Staib, Lawrence H.
    Sarkar, Saradwata
    Venkataraman, Rajesh
    Nawaf, Cayce B.
    Sprenkle, Preston C.
    Papademetris, Xenophon
    MEDICAL IMAGE ANALYSIS, 2017, 39 : 29 - 43
  • [46] Discontinuity Preserving Liver MR Registration With Three-Dimensional Active Contour Motion Segmentation
    Li, Dongxiao
    Zhong, Wenxiong
    Deh, Kofi M.
    Nguyen, Thanh D.
    Prince, Martin R.
    Wang, Yi
    Spincemaille, Pascal
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (07) : 1884 - 1897
  • [47] MR-PSMA SPECT/CT-TRUS THREE-DIMENSIONAL FUSION-TARGETED PROSTATE CYROABLATION
    Lin, Guo-Wen
    JOURNAL OF UROLOGY, 2020, 203 : E1058 - E1059
  • [48] Quantitative three-dimensional transrectal ultrasound (TRUS) for prostate imaging
    Pathak, SD
    Aarnink, RG
    de la Rosette, JJMCH
    Chalana, V
    Wijkstra, H
    Haynor, DR
    Debruyne, FMJ
    Kim, Y
    IMAGE DISPLAY - MEDICAL IMAGING 1998, 1998, 3335 : 83 - 92
  • [49] Adaptive Nonrigid Inpainting of Three-Dimensional Point Cloud Geometry
    Dinesh, Chinthaka
    Bajic, Ivan, V
    Cheung, Gene
    IEEE SIGNAL PROCESSING LETTERS, 2018, 25 (06) : 878 - 882
  • [50] Nonrigid registration of carotid ultrasound and MR images using a "twisting and bending" model
    Nanayakkara, Nuwan D.
    Chiu, Bernard
    Samani, Abbas
    Spence, J. David
    Parraga, Grace
    Samarabandu, Jagath
    Fenster, Aaron
    MEDICAL IMAGING 2008: IMAGE PROCESSING, PTS 1-3, 2008, 6914