Three-Dimensional Nonrigid MR-TRUS Registration Using Dual Optimization

被引:32
|
作者
Sun, Yue [1 ]
Yuan, Jing [1 ]
Qiu, Wu [1 ]
Rajchl, Martin [1 ]
Romagnoli, Cesare [2 ]
Fenster, Aaron [1 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Imaging, London, ON N6A 5K8, Canada
基金
加拿大健康研究院;
关键词
Convex optimization; magnetic resonance to transrectal ultrasound (MR-TRUS) prostate registration; modality independent neighborhood descriptor (MIND) similarity measurement; nonrigid image registration; GUIDED PROSTATE BIOPSY; IMAGE REGISTRATION; TRANSRECTAL ULTRASONOGRAPHY; RADICAL PROSTATECTOMY; CANCER; FLOW; SEGMENTATION; ACCURACY; MODEL;
D O I
10.1109/TMI.2014.2375207
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study, we proposed an efficient nonrigid magnetic resonance (MR) to transrectal ultrasound (TRUS) deformable registration method in order to improve the accuracy of targeting suspicious regions during a three dimensional (3-D) TRUS guided prostate biopsy. The proposed deformable registration approach employs the multi-channel modality independent neighborhood descriptor (MIND) as the local similarity feature across the two modalities of MR and TRUS, and a novel and efficient duality-based convex optimization-based algorithmic scheme was introduced to extract the deformations and align the two MIND descriptors. The registration accuracy was evaluated using 20 patient images by calculating the TRE using manually identified corresponding intrinsic fiducials in the whole gland and peripheral zone. Additional performance metrics [Dice similarity coefficient (DSC), mean absolute surface distance (MAD), and maximum absolute surface distance (MAXD)] were also calculated by comparing the MR and TRUS manually segmented prostate surfaces in the registered images. Experimental results showed that the proposed method yielded an overall median TRE of 1.76 mm. The results obtained in terms of DSC showed an average of 80.8 +/- 7.8% for the apex of the prostate, 92.0 +/- 3.4% for the mid-gland, 81.7 +/- 6.4% for the base and 85.7 +/- 4.7% for the whole gland. The surface distance calculations showed an overall average of 1.84 +/- 0.52 mm for MAD and 6.90 +/- 2.07 mm for MAXD.
引用
收藏
页码:1085 / 1095
页数:11
相关论文
共 50 条
  • [31] Non-rigid MR-TRUS image registration for image-guided prostate biopsy using correlation ratio-based mutual information
    Gong, Lun
    Wang, Haifeng
    Peng, Chengtao
    Dai, Yakang
    Ding, Min
    Sun, Yinghao
    Yang, Xiaodong
    Zheng, Jian
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [32] Biomechanically constrained non-rigid MR-TRUS prostate registration using deep learning based 3D point cloud matching
    Department of Radiation Oncology, Emory University, 1365 Clifton Road NE, Atlanta
    GA
    30322, United States
    不详
    GA
    30322, United States
    不详
    GA
    30322, United States
    Med. Image Anal.,
  • [33] Three-dimensional B-spline-based intersubject nonrigid registration with geodesic closest points constraints
    Zhang, Zhijun
    Liu, Feng
    Deng, Fuqin
    Tsui, Hungtat
    JOURNAL OF ELECTRONIC IMAGING, 2014, 23 (06)
  • [34] Three-dimensional object registration using wavelet features
    Chalfant, Julie S.
    Patrikalakis, Nicholas M.
    ENGINEERING WITH COMPUTERS, 2009, 25 (03) : 303 - 318
  • [35] Three-dimensional object registration using wavelet features
    Julie S. Chalfant
    Nicholas M. Patrikalakis
    Engineering with Computers, 2009, 25 : 303 - 318
  • [36] Non-rigid MR-TRUS image registration for image-guided prostate biopsy using correlation ratio-based mutual information
    Lun Gong
    Haifeng Wang
    Chengtao Peng
    Yakang Dai
    Min Ding
    Yinghao Sun
    Xiaodong Yang
    Jian Zheng
    BioMedical Engineering OnLine, 16
  • [37] Fourier registration of three-dimensional brain MR images: Exploiting the axis of rotation
    Kassam, A
    Wood, ML
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (06): : 894 - 902
  • [38] 3D Non-Rigid Surface-Based MR-TRUS Registration for Image-Guided Prostate Biopsy
    Sun, Yue
    Qiu, Wu
    Romagnoli, Cesare
    Fenster, Aaron
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [39] An automated three-dimensional plus time registration framework for dynamic MR renography
    Song, Ting
    Lee, Vivian S.
    Chen, Qun
    Rusinek, Henry
    Laine, Andrew F.
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2010, 21 (01) : 1 - 8
  • [40] Three-dimensional nonrigid reconstruction based on probability model
    Wang, Yaming
    Shen, Deming
    Huang, Wenqing
    Han, Yonghua
    INTERNATIONAL JOURNAL OF ADVANCED ROBOTIC SYSTEMS, 2020, 17 (01)