Three-Dimensional Nonrigid MR-TRUS Registration Using Dual Optimization

被引:32
|
作者
Sun, Yue [1 ]
Yuan, Jing [1 ]
Qiu, Wu [1 ]
Rajchl, Martin [1 ]
Romagnoli, Cesare [2 ]
Fenster, Aaron [1 ]
机构
[1] Univ Western Ontario, Robarts Res Inst, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Imaging, London, ON N6A 5K8, Canada
基金
加拿大健康研究院;
关键词
Convex optimization; magnetic resonance to transrectal ultrasound (MR-TRUS) prostate registration; modality independent neighborhood descriptor (MIND) similarity measurement; nonrigid image registration; GUIDED PROSTATE BIOPSY; IMAGE REGISTRATION; TRANSRECTAL ULTRASONOGRAPHY; RADICAL PROSTATECTOMY; CANCER; FLOW; SEGMENTATION; ACCURACY; MODEL;
D O I
10.1109/TMI.2014.2375207
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study, we proposed an efficient nonrigid magnetic resonance (MR) to transrectal ultrasound (TRUS) deformable registration method in order to improve the accuracy of targeting suspicious regions during a three dimensional (3-D) TRUS guided prostate biopsy. The proposed deformable registration approach employs the multi-channel modality independent neighborhood descriptor (MIND) as the local similarity feature across the two modalities of MR and TRUS, and a novel and efficient duality-based convex optimization-based algorithmic scheme was introduced to extract the deformations and align the two MIND descriptors. The registration accuracy was evaluated using 20 patient images by calculating the TRE using manually identified corresponding intrinsic fiducials in the whole gland and peripheral zone. Additional performance metrics [Dice similarity coefficient (DSC), mean absolute surface distance (MAD), and maximum absolute surface distance (MAXD)] were also calculated by comparing the MR and TRUS manually segmented prostate surfaces in the registered images. Experimental results showed that the proposed method yielded an overall median TRE of 1.76 mm. The results obtained in terms of DSC showed an average of 80.8 +/- 7.8% for the apex of the prostate, 92.0 +/- 3.4% for the mid-gland, 81.7 +/- 6.4% for the base and 85.7 +/- 4.7% for the whole gland. The surface distance calculations showed an overall average of 1.84 +/- 0.52 mm for MAD and 6.90 +/- 2.07 mm for MAXD.
引用
收藏
页码:1085 / 1095
页数:11
相关论文
共 50 条
  • [1] LEARNING NONRIGID DEFORMATIONS FOR CONSTRAINED POINT-BASED REGISTRATION FOR IMAGE -GUIDED MR-TRUS PROSTATE INTERVENTION
    Onofrey, John A.
    Staib, Lawrence H.
    Sarkar, Saradwata
    Venkataraman, Rajesh
    Papademetris, Xenophon
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1592 - 1595
  • [2] 3D Prostate MR-TRUS Non-Rigid Registration Using Dual Optimization with Volume-Preserving Constraint
    Qiu, Wu
    Yuan, Jing
    Fenster, Aaron
    MEDICAL IMAGING 2016: IMAGE PROCESSING, 2016, 9784
  • [3] Distance Map Supervised Landmark Localization for MR-TRUS Registration
    Song, Xinrui
    Xu, Xuanang
    Xu, Sheng
    Turkbey, Baris
    Sanford, Thomas
    Wood, Bradford J.
    Yan, Pingkun
    MEDICAL IMAGING 2023, 2023, 12464
  • [4] A MR-TRUS Registration Method for Ultrasound-Guided Prostate Interventions
    Yang, Xiaofeng
    Rossi, Peter
    Mao, Hui
    Jani, Ashesh B.
    Ogunleye, Tomi
    Curran, Walter J.
    Liu, Tian
    MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [5] Efficient Convex Optimization Approach to 3D Non-rigid MR-TRUS Registration
    Sun, Yue
    Yuan, Jing
    Rajchl, Martin
    Qiu, Wu
    Romagnoli, Cesare
    Fenster, Aaron
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT I, 2013, 8149 : 195 - 202
  • [6] Registration accuracy of an integrated MR-TRUS navigation system for prostate HDR brachytherapy
    Kadoury, S.
    Lopera, D.
    Shams, R.
    Beliveau-Nadeau, D.
    Delouya, G.
    Boudam, K.
    Carrier, J.
    Menard, C.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S122 - S123
  • [7] Statistical Biomechanical Surface Registration: Application to MR-TRUS Fusion for Prostate Interventions
    Khallaghi, Siavash
    Sanchez, C. Antonio
    Rasoulian, Abtin
    Nouranian, Saman
    Romagnoli, Cesare
    Abdi, Hamidreza
    Chang, Silvia D.
    Black, Peter C.
    Goldenberg, Larry
    Morris, William J.
    Spadinger, Ingrid
    Fenster, Aaron
    Ward, Aaron
    Fels, Sidney
    Abolmaesumi, Purang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (12) : 2535 - 2549
  • [8] Online Robust Projective Dictionary Learning: Shape Modeling for MR-TRUS Registration
    Wang, Yi
    Zheng, Qingqing
    Heng, Pheng Ann
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (04) : 1067 - 1078
  • [9] Biomechanically Constrained Surface Registration: Application to MR-TRUS Fusion for Prostate Interventions
    Khallaghi, Siavash
    Sanchez, C. Antonio
    Rasoulian, Abtin
    Sun, Yue
    Imani, Farhad
    Khojaste, Amir
    Goksel, Orcun
    Romagnoli, Cesare
    Abdi, Hamidreza
    Chang, Silvia
    Mousavi, Parvin
    Fenster, Aaron
    Ward, Aaron
    Fels, Sidney
    Abolmaesumi, Purang
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) : 2404 - 2414
  • [10] Learning deep similarity metric for 3D MR-TRUS image registration
    Haskins, Grant
    Kruecker, Jochen
    Kruger, Uwe
    Xu, Sheng
    Pinto, Peter A.
    Wood, Brad J.
    Yan, Pingkun
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (03) : 417 - 425