Xenon gamma-detector applicability for identification and characterization of radioactive waste

被引:4
|
作者
Pyae, S. N. [1 ]
Grachev, V. M. [1 ]
Dmitrenko, V. V. [1 ]
Ulin, S. E. [1 ]
Vlasik, K. F. [1 ]
Uteshev, Z. M. [1 ]
Shustov, A. E. [1 ]
Novikov, A. S. [1 ]
Petrenko, D. V. [1 ]
Chernysheva, I. V. [1 ]
机构
[1] Natl R4es Nucl Univ, MEPhI Moscow Engn Phys Inst, Kashirskoe Shosse 31, Moscow 115409, Russia
关键词
xenon gamma detector; radioactive waste; gamma ray spectrometer;
D O I
10.1016/j.phpro.2015.09.191
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
In this paper described applicability of xenon gamma detector for identification and characterization of radioactive waste was researched. Standard calibration gamma ray sources were used to determine real physical and technical characteristics of xenon gamma spectrometer. Samples of radioactive waste were measured by xenon gamma detector for identification and characterization. (C) 2015 Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:352 / 356
页数:5
相关论文
共 50 条
  • [31] Xenon gamma-ray detector for ecological applications
    Novikov, Alexander S.
    Ulin, Sergey E.
    Chernysheva, Irina V.
    Dmitrenko, Valery V.
    Grachev, Victor M.
    Petrenko, Denis V.
    Shustov, Alexander E.
    Uteshev, Ziyaetdin M.
    Vlasik, Konstantin F.
    JOURNAL OF APPLIED REMOTE SENSING, 2015, 9
  • [32] On the applicability of LaBr3 detectors in the non-destructive characterization of radioactive waste drums
    C. Göbbels
    T. Krings
    E. Mauerhofer
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 2399 - 2405
  • [33] AUTOMATED-SYSTEM FOR CALIBRATION AND MONITORING OF PARAMETERS OF CHSPP-800 MULTICHANNEL GAMMA-DETECTOR
    AVVAKUMOV, IA
    BELIKOV, NI
    GONCHARENKO, YM
    MESHCHANIN, AP
    NURUSHEV, SB
    SOLOVYANOV, VL
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (04) : 817 - 820
  • [34] Carrier gas attenuation in gamma assay of radioactive xenon samples
    Troy A. Robinson
    John P. Peterson
    Robert K. Hague
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 3015 - 3023
  • [35] Carrier gas attenuation in gamma assay of radioactive xenon samples
    Robinson, Troy A.
    Peterson, John P.
    Hague, Robert K.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (07) : 3015 - 3023
  • [37] THRESHOLD SELF-POWERED GAMMA-DETECTOR FOR USE AS A NUCLEAR-REACTOR POWER MONITOR
    LEVERT, FE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 683 - 686
  • [38] Characterization of Radioactive Hazardous Waste
    B. Hooda
    G. L. Scott
    S. B. Jones
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 243 : 551 - 553
  • [39] Characterization of radioactive hazardous waste
    Hooda, B
    Scott, GL
    Jones, SB
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 243 (02) : 551 - 553
  • [40] OPTICAL FIBER READOUT AND PERFORMANCE OF SMALL SCINTILLATING CRYSTALS FOR A FINE-GRAINED GAMMA-DETECTOR
    RUSHBROOKE, JG
    ANSORGE, RE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 280 (01): : 83 - 90