Xenon gamma-detector applicability for identification and characterization of radioactive waste

被引:4
|
作者
Pyae, S. N. [1 ]
Grachev, V. M. [1 ]
Dmitrenko, V. V. [1 ]
Ulin, S. E. [1 ]
Vlasik, K. F. [1 ]
Uteshev, Z. M. [1 ]
Shustov, A. E. [1 ]
Novikov, A. S. [1 ]
Petrenko, D. V. [1 ]
Chernysheva, I. V. [1 ]
机构
[1] Natl R4es Nucl Univ, MEPhI Moscow Engn Phys Inst, Kashirskoe Shosse 31, Moscow 115409, Russia
关键词
xenon gamma detector; radioactive waste; gamma ray spectrometer;
D O I
10.1016/j.phpro.2015.09.191
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
In this paper described applicability of xenon gamma detector for identification and characterization of radioactive waste was researched. Standard calibration gamma ray sources were used to determine real physical and technical characteristics of xenon gamma spectrometer. Samples of radioactive waste were measured by xenon gamma detector for identification and characterization. (C) 2015 Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:352 / 356
页数:5
相关论文
共 50 条
  • [21] A NEW GAMMA-DETECTOR FOR FAST COINCIDENCE MEASUREMENTS WITH A GOOD ENERGY RESOLUTION
    DEBOER, TJ
    KLEIN, SS
    TENNAPEL, EW
    BLOK, J
    NUCLEAR INSTRUMENTS & METHODS, 1963, 21 (02): : 347 - 348
  • [22] Liquid xenon gamma ray detector for MEG
    Sawada, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 522 - 525
  • [23] Advanced Sectorial Gamma Scanning for the Radiological Characterization of Radioactive Waste Packages
    Duerr, M.
    Fritzsche, M.
    Krycki, K.
    Hansmann, B.
    Hansmann, T.
    Havenith, A.
    Pasler, D.
    Hartmann, T.
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2019, 64 (03): : 160 - 166
  • [24] Simulation of the xenon gamma spectrometer for analyzing radioactive materials
    P'ya, S. N.
    Vlasik, K. F.
    Grachev, V. M.
    Dmitrenko, V. V.
    Novikov, A. S.
    Petrenko, D. V.
    Shustov, A. E.
    Uteshev, Z. M.
    Ulin, S. E.
    Chernysheva, I. V.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2014, 41 (09) : 247 - 251
  • [25] Simulation of the xenon gamma spectrometer for analyzing radioactive materials
    S. N. P’ya
    K. F. Vlasik
    V. M. Grachev
    V. V. Dmitrenko
    A. S. Novikov
    D. V. Petrenko
    A. E. Shustov
    Z. M. Uteshev
    S. E. Ulin
    I. V. Chernysheva
    Bulletin of the Lebedev Physics Institute, 2014, 41 : 247 - 251
  • [26] THE USE OF A HAND-HELD GAMMA-DETECTOR IMPROVES THE SAFETY OF ISOLATED LIMB PERFUSION
    SARDI, A
    MINTON, JP
    MOJZISIK, C
    NIERODA, CA
    FERRARA, PJ
    HINKLE, GH
    THURSTON, MO
    MARTIN, EW
    JOURNAL OF SURGICAL ONCOLOGY, 1989, 41 (03) : 172 - 176
  • [27] Application of xenon gamma-ray detectors in portal monitors for detection and identification of radioactive and fissile materials
    Ulin, S. E.
    Dmitrenko, V. V.
    Galper, A. M.
    Vlasik, K. F.
    Uteshev, Z. M.
    Dvornyak, P. G.
    Ischenko, A. D.
    Ivanova, N. A.
    Gecha, V. Y.
    Boyartchuk, A. K.
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND PENETRATING RADIATION SYSTEMS VIII, 2006, 6319
  • [28] An improved method for the non-destructive characterization of radioactive waste by gamma scanning
    Bai, Y. F.
    Mauerhofer, E.
    Wang, D. Z.
    Odoj, R.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (10) : 1897 - 1903
  • [29] Performance of liquid xenon gamma ray detector for MEG
    Sawada, Ryu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 258 - 260
  • [30] On the applicability of LaBr3 detectors in the non-destructive characterization of radioactive waste drums
    Goebbels, C.
    Krings, T.
    Mauerhofer, E.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 303 (03) : 2399 - 2405