The Effect of Successful Rebubbling After Descemet Stripping Automated Endothelial Keratoplasty on Endothelial Cell Counts

被引:13
|
作者
Shehadeh, Raneen [1 ]
Kaiserman, Igor [2 ,3 ]
Kumar, Nikhil [1 ]
Sansanayudh, Wiwan [1 ]
Rootman, David [1 ]
机构
[1] Univ Toronto, Dept Ophthalmol, Toronto Western Hosp, Toronto, ON M5T 2S8, Canada
[2] Barzilai Govt Hosp, Dept Ophthalmol, Ashqelon, Israel
[3] Ben Gurion Univ Negev, Fac Hlth Sci, Beer Sheva, Israel
关键词
DSAEK; repositioning; rebubbling; endothelial cell loss; PENETRATING KERATOPLASTY; VISUAL-ACUITY; EYES; DISLOCATION;
D O I
10.1097/ICO.0b013e3181cb40f6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the effect of successful repositioning/rebubbling of the graft on endothelial cell counts (ECCs) in eyes after Descemet stripping automated endothelial keratoplasty. Methods: This retrospective study reviewed the outcomes of 58 eyes that underwent Descemet stripping automated endothelial keratoplasty. Fifty-one eyes were attached after surgery. Seven were detached and underwent rebubbling with minimal manipulation in 5 and significant manipulation in 2, after which the graft was attached and clear. Visual outcomes and endothelial cell loss at 6 months were compared between eyes that underwent repositioning/ rebubbling and those that did not. The following were excluded: 2 eyes that had primary failure, 2 eyes that had rejection, 1 eye that failed to attach after rebubbling, 2 eyes that failed to clear after rebubbling, and 24 eyes that did not have ECC at 6 months. Results: The 2 groups were comparable considering age, preoperative best-corrected visual acuity, surgical variables, combined procedures, donor cell count, and graft size. The mean postoperative spherical equivalent, manifest and topographic astigmatism, uncorrected visual acuity, and best-corrected visual acuity did not differ significantly between the 2 groups at 6 months. Mean pre- and postoperative ECC did not differ significantly between the group that underwent repositioning/ rebubbling and the group that did not (preoperative counts 2742 6 268 vs. 2747 6 353 and postoperative counts 1590 6 367 vs. 1746 6 491, respectively). Endothelial cell loss also did not differ significantly between the 2 groups, although there was a trend to greater cell loss in the reattachment group (-39.4% +/- 11.1% vs. -38.3% +/- 16.2%, respectively; P = 0.6). Conclusion: Successful reattachment procedure does not seem to cause significant endothelial cell loss.
引用
收藏
页码:878 / 882
页数:5
相关论文
共 50 条
  • [41] Descemet Membrane Endothelial Keratoplasty After Failed Descemet Stripping Without Endothelial Keratoplasty
    Rao, Rohini
    Borkar, Durga S.
    Colby, Kathryn A.
    Veldman, Peter B.
    CORNEA, 2017, 36 (07) : 763 - 766
  • [42] Descemet Stripping Automated Endothelial Keratoplasty versus Descemet Membrane Endothelial Keratoplasty for Fuchs Endothelial Corneal Dystrophy
    Viberg, Andreas
    Samolov, Branka
    Bystroem, Berit
    OPHTHALMOLOGY, 2023, 130 (12) : 1248 - 1257
  • [43] Deep Anterior Lamellar Keratoplasty After Descemet Stripping Automated Endothelial Keratoplasty
    Busin, Massimo
    Beltz, Jacqueline
    CORNEA, 2011, 30 (09) : 1048 - 1050
  • [44] Deep Anterior Lamellar Keratoplasty After Descemet Stripping Automated Endothelial Keratoplasty
    Gutfreund, Shay
    Leon, Pia
    Graffi, Shmuel
    Busin, Massimo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 175 : 129 - 136
  • [45] Intraocular Pressure After Descemet Stripping and Non-Descemet Stripping Automated Endothelial Keratoplasty
    Mawatari, Y.
    Kobayashi, A.
    Yokogawa, H.
    Sugiyama, K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] Comparison of Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty in the Treatment of Failed Penetrating Keratoplasty
    Einan-Lifshitz, Adi
    Mednick, Zale
    Belkin, Avner
    Sorkin, Nir
    Alshaker, Sara
    Boutin, Tanguy
    Chan, Clara C.
    Rootman, David S.
    CORNEA, 2019, 38 (09) : 1077 - 1082
  • [47] Effect of the shape of the endothelial graft on the refractive results after Descemet's stripping with automated endothelial keratoplasty
    Esquenazi, Salomon
    Rand, William
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (05): : 557 - 561
  • [48] Repeat keratoplasty in failed Descemet stripping automated endothelial keratoplasty
    Kaur, Manpreet
    Titiyal, Jeewan S.
    Gagrani, Meghal
    Shaikh, Farin
    Agarwal, Tushar
    Sinha, Rajesh
    Sharma, Namrata
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1586 - 1592
  • [49] Descemet stripping and automated endothelial keratoplasty: An alternative to penetrating keratoplasty
    Chih, Andreea
    Lugo, Miguel
    Kowing, Dianne
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (03) : 152 - 157
  • [50] Systematic Review and Meta-Analysis of Clinical Outcomes of Descemet Membrane Endothelial Keratoplasty Versus Descemet Stripping Endothelial Keratoplasty/Descemet Stripping Automated Endothelial Keratoplasty
    Singh, Abhimanyu
    Zarei-Ghanavati, Mehran
    Avadhanam, Venkata
    Liu, Christopher
    CORNEA, 2017, 36 (11) : 1437 - 1443