The Effect of Successful Rebubbling After Descemet Stripping Automated Endothelial Keratoplasty on Endothelial Cell Counts

被引:13
|
作者
Shehadeh, Raneen [1 ]
Kaiserman, Igor [2 ,3 ]
Kumar, Nikhil [1 ]
Sansanayudh, Wiwan [1 ]
Rootman, David [1 ]
机构
[1] Univ Toronto, Dept Ophthalmol, Toronto Western Hosp, Toronto, ON M5T 2S8, Canada
[2] Barzilai Govt Hosp, Dept Ophthalmol, Ashqelon, Israel
[3] Ben Gurion Univ Negev, Fac Hlth Sci, Beer Sheva, Israel
关键词
DSAEK; repositioning; rebubbling; endothelial cell loss; PENETRATING KERATOPLASTY; VISUAL-ACUITY; EYES; DISLOCATION;
D O I
10.1097/ICO.0b013e3181cb40f6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the effect of successful repositioning/rebubbling of the graft on endothelial cell counts (ECCs) in eyes after Descemet stripping automated endothelial keratoplasty. Methods: This retrospective study reviewed the outcomes of 58 eyes that underwent Descemet stripping automated endothelial keratoplasty. Fifty-one eyes were attached after surgery. Seven were detached and underwent rebubbling with minimal manipulation in 5 and significant manipulation in 2, after which the graft was attached and clear. Visual outcomes and endothelial cell loss at 6 months were compared between eyes that underwent repositioning/ rebubbling and those that did not. The following were excluded: 2 eyes that had primary failure, 2 eyes that had rejection, 1 eye that failed to attach after rebubbling, 2 eyes that failed to clear after rebubbling, and 24 eyes that did not have ECC at 6 months. Results: The 2 groups were comparable considering age, preoperative best-corrected visual acuity, surgical variables, combined procedures, donor cell count, and graft size. The mean postoperative spherical equivalent, manifest and topographic astigmatism, uncorrected visual acuity, and best-corrected visual acuity did not differ significantly between the 2 groups at 6 months. Mean pre- and postoperative ECC did not differ significantly between the group that underwent repositioning/ rebubbling and the group that did not (preoperative counts 2742 6 268 vs. 2747 6 353 and postoperative counts 1590 6 367 vs. 1746 6 491, respectively). Endothelial cell loss also did not differ significantly between the 2 groups, although there was a trend to greater cell loss in the reattachment group (-39.4% +/- 11.1% vs. -38.3% +/- 16.2%, respectively; P = 0.6). Conclusion: Successful reattachment procedure does not seem to cause significant endothelial cell loss.
引用
收藏
页码:878 / 882
页数:5
相关论文
共 50 条
  • [21] Candida keratitis after Descemet stripping with automated endothelial keratoplasty
    Villarrubia, Alberto
    Cano-Ortiz, Antonio
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2014, 24 (06) : 964 - 967
  • [22] Corneal Sensation After Descemet Stripping and Automated Endothelial Keratoplasty
    Kumar, Radhika L.
    Koenig, Steven B.
    Covert, Douglas J.
    CORNEA, 2010, 29 (01) : 13 - 18
  • [23] Microbial Keratitis After Descemet Stripping Automated Endothelial Keratoplasty
    Sharma, Namrata
    Agarwal, Prakash Chand
    Kumar, Chandra Shekhar
    Mannan, Rashim
    Titiyal, Jeewan S.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (05): : 320 - 322
  • [24] Epithelial Downgrowth After Descemet Stripping Automated Endothelial Keratoplasty
    Gorovoy, Mark S.
    Ratanasit, Arlene
    CORNEA, 2010, 29 (10) : 1192 - 1194
  • [25] Graft Detachment After Descemet Stripping Automated Endothelial keratoplasty
    Cardascia, Nicola
    La Tegola, Gabriella
    Pastore, Valentina
    Bini, Vito
    Alessio, Giovanni
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [26] Interface Blood After Descemet Stripping Automated Endothelial Keratoplasty
    Schmitt, Artur J.
    Feilmeier, Michael R.
    Piccoli, Fernanda V.
    Ide, Takeshi
    Yoo, Sonia H.
    CORNEA, 2011, 30 (07) : 815 - 817
  • [27] Candida Keratitis After Descemet Stripping and Automated Endothelial Keratoplasty
    Koenig, Steven B.
    Wirostko, William J.
    Fish, Robert I.
    Covert, Douglas J.
    CORNEA, 2009, 28 (04) : 471 - 473
  • [28] Interface Haze After Descemet Stripping Automated Endothelial Keratoplasty
    Ting, Darren Shu Jeng
    Said, Dalia G.
    Dua, Harminder S.
    JAMA OPHTHALMOLOGY, 2019, 137 (10) : 1201 - 1202
  • [29] Descemet stripping automated endothelial keratoplasty for microcornea
    Hiroshi Toshida
    Toshihiko Ohta
    Akira Murakami
    Akira Kobayashi
    Kazuhisa Sugiyama
    Japanese Journal of Ophthalmology, 2012, 56 : 436 - 440
  • [30] Descemet stripping automated endothelial keratoplasty for microcornea
    Toshida, Hiroshi
    Ohta, Toshihiko
    Murakami, Akira
    Kobayashi, Akira
    Sugiyama, Kazuhisa
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (05) : 436 - 440