Phase shifters in a high frequency pulse tube cryocooler

被引:0
|
作者
Ma, J [1 ]
Hou, YK [1 ]
Long, XH [1 ]
Jing, W [1 ]
Zhou, Y [1 ]
机构
[1] Chinese Acad Agr Sci, Dev Strategy Res Dept, Beijing 100081, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The double-inlet and inertance tube as phase shifters; used in a high frequency miniature pulse tube cryocooler (PTC) are experimental investigated. For the double-inlet PTC, the optimum adjusting method of the orifice and secondary bypass is different from the traditional method. The experimental results show that the lowest temperature obtained by the optimum adjusting method is 1.5-5K lower than that by the traditional method at different charge pressures and operating frequencies. As phase shifters used in high frequency miniature PTC, inertance tubes can cause impedance unmatching phenomenon. When the phase angle that the pressure leads the volume velocity at the hot end of the PTC is large, the impedance at the hot end is small.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 50 条
  • [41] Performance of a miniature pulse tube cryocooler
    Matsumoto, N.
    Yasukawa, Y.
    Ohshima, K.
    Minematsu, S.
    Takeuchi, T.
    Yoshizawa, K.
    Matsushita, T.
    Mizoguchi, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 712 - +
  • [43] Development of the miniature pulse tube cryocooler
    Matsumoto, N
    Yasukawa, Y
    Ohshima, K
    Toyama, K
    Tsukahara, Y
    Kamoshita, T
    Takeuchi, T
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS. 49A AND B, 2004, 710 : 1339 - 1346
  • [44] Pulse tube cryocooler for IR applications
    Korf, H
    Rühlich, I
    Mai, M
    Thummes, G
    Infrared Technology and Applications XXXI, Pts 1 and 2, 2005, 5783 : 164 - 168
  • [45] AIRS pulse tube cryocooler system
    Chan, CK
    Raab, J
    Eskovitz, A
    Carden, R
    Fletcher, M
    Orsini, R
    CRYOCOOLERS 9, 1997, : 895 - 903
  • [46] PULSE TUBE CRYOCOOLER DYNAMICS AND SIMULATION
    Davis, Christopher
    Sarigul-Klijn, Nesrin
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 1, 2012, : 289 - 296
  • [47] A pulse tube cryocooler with a cold reservoir
    Zhang, X. B.
    Zhang, K. H.
    Qiu, L. M.
    Gan, Z. H.
    Shen, X.
    Xiang, S. J.
    CRYOGENICS, 2013, 54 : 30 - 36
  • [48] Study on the flow nonuniformity in a high capacity Stirling pulse tube cryocooler
    You, X.
    Zhi, X.
    Duan, C.
    Jiang, X.
    Qiu, L.
    Li, J.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [49] A high efficiency coaxial pulse tube cryocooler operating at 60 K
    Wang, Nailiang
    Zhao, Miguang
    Ou, Yangyang
    Zhu, Qianglong
    Wei, Lingjiao
    Chen, Houlei
    Cai, Jinghui
    Liang, Jingtao
    CRYOGENICS, 2018, 93 : 48 - 50
  • [50] Optimization of regenerator in high capacity Stirling type pulse tube cryocooler
    Imura, J.
    Iwata, N.
    Yamamoto, H.
    Ohashi, Y.
    Nomachi, H.
    Okumura, N.
    Nagaya, S.
    Tamada, T.
    Hirano, N.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2008, 468 (15-20): : 2178 - 2180