Phase shifters in a high frequency pulse tube cryocooler

被引:0
|
作者
Ma, J [1 ]
Hou, YK [1 ]
Long, XH [1 ]
Jing, W [1 ]
Zhou, Y [1 ]
机构
[1] Chinese Acad Agr Sci, Dev Strategy Res Dept, Beijing 100081, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The double-inlet and inertance tube as phase shifters; used in a high frequency miniature pulse tube cryocooler (PTC) are experimental investigated. For the double-inlet PTC, the optimum adjusting method of the orifice and secondary bypass is different from the traditional method. The experimental results show that the lowest temperature obtained by the optimum adjusting method is 1.5-5K lower than that by the traditional method at different charge pressures and operating frequencies. As phase shifters used in high frequency miniature PTC, inertance tubes can cause impedance unmatching phenomenon. When the phase angle that the pressure leads the volume velocity at the hot end of the PTC is large, the impedance at the hot end is small.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 50 条
  • [21] Simulation and experimental investigation of gravity effect in high-frequency pulse tube cryocooler
    Hou, Xiao-Feng
    Chen, Hou-Lei
    Yang, Lu-Wei
    Liang, Jing-Tao
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2008, 29 (11): : 1809 - 1812
  • [22] Matching characteristics of single-stage high-frequency pulse tube cryocooler
    Technical Institute of Physics and Chemistry, CAS, Beijing 100080, China
    不详
    Kung Cheng Je Wu Li Hsueh Pao, 2007, SUPPL. 1 (29-32):
  • [23] 80 K high-frequency nonmagnetic and nonmetallic pulse-tube cryocooler
    Xun, Yu-Qiang
    Yang, Lu-Wei
    Cai, Jing-Hui
    Liang, Jing-Tao
    Zhou, Yuan
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2009, 30 (12): : 2007 - 2009
  • [24] Progress of pulse tube cryocooler
    Matsubara, Yoichi
    Koh, Deuk-Yong
    Journal of the Korea Institute of Applied Superconductivity and Cryogenics, 2010, 12 (04): : 1 - 7
  • [25] Investigations on the Four-stage High Frequency Pulse Tube Cryocooler With Self-precooling
    Tan, Jun
    Zha, Rui
    Zhang, Tao
    Li, Jia-Qi
    Zhao, Yong-Jiang
    Zhao, Bang-Jian
    Tan, Han
    Xue, Ren-Jun
    Dang, Hai-Zheng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (04): : 841 - 846
  • [26] Influence of Regenerator Material on Performance of a 6K High Frequency Pulse Tube Cryocooler
    Quan, J.
    Liu, Y. J.
    Li, X. Y.
    Liang, J. T.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278
  • [27] The Investigation on Phase Shifter of VM Type Pulse Tube Cryocooler
    Wang, Ya-Nan
    Dai, Wei
    Wang, Xiao-Tao
    Luo, Er-Cang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2019, 40 (02): : 258 - 262
  • [28] Development of high capacity Stirling type pulse tube cryocooler
    Imura, J.
    Shinoki, S.
    Sato, T.
    Iwata, N.
    Yamamoto, H.
    Yasohama, K.
    Ohashi, Y.
    Nomachi, H.
    Okumura, N.
    Nagaya, S.
    Tamada, T.
    Hirano, N.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2007, 463 : 1369 - 1371
  • [29] A high efficiency hybrid stirling-pulse tube cryocooler
    Wang, Xiaotao
    Zhang, Yibing
    Li, Haibing
    Dai, Wei
    Chen, Shuai
    Lei, Gang
    Luo, Ercang
    AIP ADVANCES, 2015, 5 (03):
  • [30] Study on High-Power Pulse Tube Cryocooler With Linear Motor Type Phase Adjuster
    Hou, Ming-Yu
    Li, Lin-Yu
    Wu, Zhang-Hua
    Luo, Er-Cang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2019, 40 (03): : 484 - 489