Investigation of undersampling and reconstruction algorithm dependence on respiratory correlated 4D-MRI for online MR-guided radiation therapy

被引:44
|
作者
Mickevicius, Nikolai J. [1 ]
Paulson, Eric S. [1 ,2 ,3 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI USA
[2] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Dept Radiol, 8700 W Wisconsin Ave, Milwaukee, WI 53226 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 08期
关键词
4D-MRI; MR simulation; MR-gRT; MR-guided RT; LINAC; SYSTEM; IMAGE; MOTION; RADIOTHERAPY; SIGNAL;
D O I
10.1088/1361-6560/aa54f2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work is to investigate the effects of undersampling and reconstruction algorithm on the total processing time and image quality of respiratory phase-resolved 4D MRI data. Specifically, the goal is to obtain quality 4D-MRI data with a combined acquisition and reconstruction time of five minutes or less, which we reasoned would be satisfactory for pre-treatment 4D-MRI in online MRI-gRT. A 3D stack-of-stars, self-navigated, 4D-MRI acquisition was used to scan three healthy volunteers at three image resolutions and two scan durations. The NUFFT, CG-SENSE, SPIRiT, and XD-GRASP reconstruction algorithms were used to reconstruct each dataset on a high performance reconstruction computer. The overall image quality, reconstruction time, artifact prevalence, and motion estimates were compared. The CG-SENSE and XD-GRASP reconstructions provided superior image quality over the other algorithms. The combination of a 3D SoS sequence and parallelized reconstruction algorithms using computing hardware more advanced than those typically seen on product MRI scanners, can result in acquisition and reconstruction of high quality respiratory correlated 4D-MRI images in less than five minutes.
引用
收藏
页码:2910 / 2921
页数:12
相关论文
共 50 条
  • [31] Technical feasibility and clinical evaluation of 4D-MRI guided liver SBRT on the MR-linac
    van de Lindt, T. N.
    Nowee, M. E.
    Janssen, T.
    Schneider, C.
    Remeijer, P.
    van Pelt, V. W. J.
    Betgen, A.
    Jansen, E. P. M.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 167 : 285 - 291
  • [32] Patterns of Response in HNSCC Subregions Using Daily Quantitative MRI from MR-Guided Radiation Therapy
    Bonate, R.
    Awan, M. J.
    Shukla, M. E.
    Tarima, S.
    Himburg, H. A.
    Zenga, J.
    Paulson, E. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : S101 - S101
  • [33] First Clinical Use of 4D-MRI for Online Adaptive MR-gRT on a High Field MR-Linac
    Mickevicius, N.
    Straza, M. W., Jr.
    Hall, W. A.
    Paulson, E. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : S30 - S31
  • [34] Using 3D Dosimeters for the Investigation of the Electron Return Effect (ERE) in MR-Guided Radiation Therapy: A Feasibility Study
    Choi, G.
    Lee, H.
    Alqathami, M.
    Ibbott, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3856 - 3856
  • [35] A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac
    Chen, Xinfeng
    Ahunbay, Ergun
    Paulson, Eric S.
    Chen, Guangpei
    Li, X. Allen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01): : 205 - 212
  • [36] Delivered dose reconstruction for MR-guided SBRT of pancreatic tumors with fast 3D cine MRI
    Grimbergen, G.
    Potgens, G.
    Eijkelenkamp, H.
    Raaymakers, B.
    Intven, M.
    Meijer, G.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S650 - S651
  • [37] Fast and robust online adaptive planning in stereotactic MR-guided adaptive radiation therapy (SMART) for pancreatic cancer
    Bohoudi, O.
    Bruynzeel, A. M. E.
    Senan, S.
    Cuijpers, J. P.
    Slotman, B. J.
    Lagerwaard, F. J.
    Palacios, M. A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 125 (03) : 439 - 444
  • [38] Stereotactic MR-guided Online Adaptive Radiation Therapy with High Dose Rate (SMART-HDR) Brachytherapy
    Mittauer, K. E.
    Miller, J.
    Bradley, K. A.
    Bayouth, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S182 - S182
  • [39] Dosimetric and Clinical Evaluation of Stereotactic MR-Guided Online Adaptive Radiation Therapy (SMART) for Treatment of Adrenal Metastases
    Ugurluer, G.
    Serkizyan, A.
    Mustafayev, T. Zoto
    Atalar, B.
    Abacioglu, M. U.
    Gungor, G.
    Ozyar, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E481 - E482
  • [40] In-Room MRI for Adaptive Radiotherapy for Cervical Cancer Using an Integrated MR-Guided Radiation Therapy System
    Tadic, T.
    Croke, J. M.
    Xie, J.
    Stanescu, T.
    Letourneau, D.
    Bissonnette, J. P.
    Breen, S.
    Simeonov, A.
    Dickie, C. I.
    Hill, C.
    Li, W.
    Ellis, C.
    Winter, J.
    Velec, M.
    Fyles, A.
    Han, K.
    Jaffray, D. A.
    Milosevic, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E736 - E737