A daily end-to-end quality assurance workflow for MR-guided online adaptive radiation therapy on MR-Linac

被引:18
|
作者
Chen, Xinfeng [1 ]
Ahunbay, Ergun [1 ]
Paulson, Eric S. [1 ]
Chen, Guangpei [1 ]
Li, X. Allen [1 ]
机构
[1] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
来源
关键词
adaptive RT; daily end-to-end QA workflow; MR-Linac; DOSE CALCULATION; RADIOTHERAPY;
D O I
10.1002/acm2.12786
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Magnetic Resonance (MR)-guided online adaptive radiation therapy (MRgOART), enabled with MR-Linac, has potential to revolutionize radiation therapy. MRgOART is a complex process. This work is to introduce a comprehensive end-to-end quality assurance (QA) workflow in routine clinic for MRgOART with a high-magnetic-field MR-Linac. Materials and Method The major components in MRgOART with a high-magnetic field MR-Linac (Unity, Elekta) include: (1) a patient record and verification (R&V) system (e.g., Mosaiq, Elekta), (2) a treatment session manager, (3) an offline treatment planning system (TPS), (4) an online adaptive TPS, (5) a 1.5T MRI scanner, (6) an 7MV Linac, (7) an MV imaging controller (MVIC), and (8) ArtQA: software for plan data consistency checking and secondary dose calculation. Our end-to-end QA workflow was designed to test the performance and connectivity of all these components by transferring, adapting and delivering a specifically designed five-beam plan on a phantom. Beams 1-4 were designed to check Multi-Leaves Collimator (MLC) position shift based on rigid image registration in TPS, while beam 5 was used to check daily radiation output based on image pixel factor of MV image of the field. The workflow is initiated in the R&V system and followed by acquiring and registering daily MRI of the phantom, checking isocenter shift, performing online adaptive replanning, checking plan integrity and secondary 3D dose calculation, delivering the plan while acquiring MV imaging using MVIC, acquiring real-time images of the phantom, and checking the delivering parameters with ArtQA. Results It takes 10 min to finish the entire end-to-end QA workflow. The workflow has detected communication problems, permitted resolution prior to setting up patients for MRgOART. Up to 0.9 mm discrepancies in isocenter shift based on the image registration were detected. ArtQA performed the secondary 3D dose calculation, verified the plan integrity as well as the MR-MV isocenter alignment values in TPS. The MLC shapes of beam 1-4 in all adaptive plans were conformal to the target and agreed with MV images. The variation of daily output was within +/- 2.0%. Conclusions The comprehensive end-to-end QA workflow can efficiently check the performance and communication between different components in MRgOART and has been successfully implemented for daily clinical practice.
引用
收藏
页码:205 / 212
页数:8
相关论文
共 50 条
  • [1] A Daily End-To-End Quality Assurance Workflow for MRI-Guided Online Adaptive Radiation Therapy
    Chen, X.
    Ahunbay, E.
    Paulson, E.
    Chen, G.
    Li, X. Allen
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E416 - E416
  • [2] An end-to-end test for MR-guided online adaptive radiotherapy
    Hoffmans, Daan
    Niebuhr, Nina
    Bohoudi, Omar
    Pfaffenberger, Asja
    Palacios, Miguel
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (12):
  • [3] Elekta Unity MR-Linac Daily Automated End-To-End Quality Control
    Malkov, V.
    Winter, J.
    Letourneau, D.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E274 - E275
  • [4] An end-to-end assessment on the accuracy of adaptive radiotherapy in an MR-linac
    Axford, A.
    Dikaios, N.
    Roberts, D. A.
    Clark, C. H.
    Evans, P. M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [5] End-To-End Deviation Validation of Image Registration in MR-Linac Online Adaptive Radiotherapy
    Yin, P.
    Li, Z.
    Yin, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E759 - E760
  • [6] MR-linac daily semi-automated end-to-end quality control verification
    Malkov, Victor N.
    Winter, Jeff D.
    Mateescu, Dan
    Letourneau, Daniel
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):
  • [7] A film-based end-to-end test for MR-guided online adaptive radiotherapy
    Hoffmans, D.
    Bohoudi, O.
    Niebuhr, N.
    Pfaffenberger, A.
    Battum, L.
    Slotman, B.
    Palacios, M.
    Bruynzeel, A.
    Lagerwaard, F.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S209 - S210
  • [8] Brain stereotactic radiosurgery using MR-guided online adaptive planning for daily setup variation: An end-to-end test
    Han, Eun Young
    Wang, He
    Briere, Tina Marie
    Yeboa, Debra Nana
    Boursianis, Themistoklis
    Kalaitzakis, Georgios
    Pappas, Evangelos
    Castillo, Pamela
    Yang, Jinzhong
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (03):
  • [9] Brain Stereotactic Radiosurgery Using MR-Guided Online Adaptive Planning to Daily Setup Variation: An End-To-End Test
    Han, E.
    Wang, H.
    Briere, T.
    Yeboa, D.
    Boursianis, T.
    Kalaitzakis, G.
    Pappas, E.
    Castillo, P.
    Yang, J.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [10] An End-to-End Verification of Online Adaptation Process on a High-Field MR-Linac
    Ahunbay, E. E.
    Chen, X.
    Paulson, E. S.
    Chen, G. P.
    Li, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S131 - S131