A preliminary evaluation work on a 3-D ultrasound imaging system for 2-D array transducer

被引:0
|
作者
Zhong, Xiaoli [1 ]
Li, Xu [1 ]
Yang, Jiali [1 ]
Li, Chunyu [1 ]
Song, Junjie [1 ]
Ding, Mingyue [1 ]
Ming Yuchi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Key Lab Image Proc & Intelligence Control, Sch Life Sci & Technol, Dept Biomed Engn,Minist Educ, Wuhan 430074, Hubei, Peoples R China
关键词
3-D ultrasound imaging system; 2-D array transducer; performance evaluation; DESIGN;
D O I
10.1117/12.2216232
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper presents a preliminary evaluation work on a pre-designed 3-D ultrasound imaging system. The system mainly consists of four parts, a 7.5MHz, 24x24 2-D array transducer, the transmit/receive circuit, power supply, data acquisition and real-time imaging module. The row-column addressing scheme is adopted for the transducer fabrication, which greatly reduces the number of active channels. The element area of the transduceris 4.6mm by 4.6mm, Four kinds of tests were carried out to evaluate the imaging performance, including the penetration depth range, axial and lateral resolution, positioning accuracy and 3-D imaging frame rate. Several strong reflection metal objects, fixed in a water tank, were selected for the purpose of imaging due to a low signal-to-noise ratio of the transducer. The distance between the transducer and the tested objects, the thickness of aluminum, and the seam width of the aluminum sheet were measured by a calibrated micrometer to evaluate the penetration depth, the axial and lateral resolution, respectively. The experimental results showed that the imaging penetration depth range was from 1.0cm to 6.2cm, the axial and lateral resolution were 0.32mm and 1.37mm respectively, the imaging speed was up to 27 frames per second and the positioning accuracy was 9.2%.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] OPTIMIZE YOUR GRAPHICS SYSTEM FOR 2-D AND 3-D
    KHURANA, AS
    GARBE, O
    EDN, 1987, 32 (06) : 161 - &
  • [42] MORPHING IN 2-D AND 3-D
    HALL, V
    DR DOBBS JOURNAL, 1993, 18 (07): : 18 - 20
  • [43] Quantitative 3-D diagnostic ultrasound imaging using a modified transducer array and an automated image tracking technique
    Hossack, JA
    Sumanaweera, TS
    Napel, S
    Ha, JS
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1029 - 1038
  • [44] A 5-MHz Cylindrical Dual-Layer Transducer Array for 3-D Transrectal Ultrasound Imaging
    Chen, Yuling
    Nguyen, Man
    Yen, Jesse T.
    ULTRASONIC IMAGING, 2012, 34 (03) : 181 - 195
  • [45] A new imaging technique of 3-D velocity vector distribution using 2-D phased array probe
    Shiina, T
    Nitta, N
    1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2, 1998, : 1509 - 1512
  • [46] New imaging technique of 3-D velocity vector distribution using 2-D phased array probe
    Shiina, Tsuyoshi
    Nitta, Naotaka
    Proceedings of the IEEE Ultrasonics Symposium, 1998, 2 : 1509 - 1512
  • [47] 2-D AND 3-D ULTRASOUND FOR TUMOR VOLUME ANALYSIS: A PROSPECTIVE STUDY
    Gonzalez, Segundo J.
    Mooney, Blaise
    Lin, Hui-Yi
    Zhao, Xiuhua
    Kiluk, John V.
    Khakpour, Nazanin
    Laronga, Christine
    Lee, M. Catherine
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (04): : 775 - 781
  • [48] Focused array transducer for 2-D OA tomography
    Makarov, VA
    Pelivanov, IM
    Kozhushko, VV
    Khokhlova, TD
    Zharinov, AN
    Karabutov, AA
    BIOMEDICAL OPTOACOUSTICS IV, 2003, 4960 : 156 - 167
  • [49] Strain Imaging Using a Rectilinear 2-D Array: Preliminary Results
    Awad, Samer I.
    Lye, Yan Lin
    Yen, Jesse T.
    2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1270 - 1273
  • [50] Real-time 3-D intracranial ultrasound with an endoscopic matrix array transducer
    Light, Edward D.
    Mukundan, Srinivasan
    Wolf, Patrick D.
    Smith, Stephen W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (08): : 1277 - 1284