A preliminary evaluation work on a 3-D ultrasound imaging system for 2-D array transducer

被引:0
|
作者
Zhong, Xiaoli [1 ]
Li, Xu [1 ]
Yang, Jiali [1 ]
Li, Chunyu [1 ]
Song, Junjie [1 ]
Ding, Mingyue [1 ]
Ming Yuchi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Key Lab Image Proc & Intelligence Control, Sch Life Sci & Technol, Dept Biomed Engn,Minist Educ, Wuhan 430074, Hubei, Peoples R China
关键词
3-D ultrasound imaging system; 2-D array transducer; performance evaluation; DESIGN;
D O I
10.1117/12.2216232
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper presents a preliminary evaluation work on a pre-designed 3-D ultrasound imaging system. The system mainly consists of four parts, a 7.5MHz, 24x24 2-D array transducer, the transmit/receive circuit, power supply, data acquisition and real-time imaging module. The row-column addressing scheme is adopted for the transducer fabrication, which greatly reduces the number of active channels. The element area of the transduceris 4.6mm by 4.6mm, Four kinds of tests were carried out to evaluate the imaging performance, including the penetration depth range, axial and lateral resolution, positioning accuracy and 3-D imaging frame rate. Several strong reflection metal objects, fixed in a water tank, were selected for the purpose of imaging due to a low signal-to-noise ratio of the transducer. The distance between the transducer and the tested objects, the thickness of aluminum, and the seam width of the aluminum sheet were measured by a calibrated micrometer to evaluate the penetration depth, the axial and lateral resolution, respectively. The experimental results showed that the imaging penetration depth range was from 1.0cm to 6.2cm, the axial and lateral resolution were 0.32mm and 1.37mm respectively, the imaging speed was up to 27 frames per second and the positioning accuracy was 9.2%.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] 2-D to 3-D conversion: The future of medical imaging
    Bendelstein, Harold L.
    ENT-EAR NOSE & THROAT JOURNAL, 2017, 96 (12) : 450 - 451
  • [32] Methods for 2-D and 3-D Endobronchial Ultrasound Image Segmentation
    Zang, Xiaonan
    Bascom, Rebecca
    Gilbert, Christopher
    Toth, Jennifer
    Higgins, William
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (07) : 1426 - 1439
  • [33] 2-D and 3-D endoluminal ultrasound: Vascular and nonvascular applications
    Liu, JB
    Goldberg, BB
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (02): : 159 - 173
  • [34] 3-D Ultrasound Imaging Using Helicoid Array Transducers
    Kim, Young-Joong
    Wolf, Patrick D.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 697 - 706
  • [35] 3-D Millimeter Wave Fast Imaging Technique Based on 2-D SISO/MIMO Array
    Lin, Bo
    Yuan, Yubing
    Ji, Yicai
    Li, Chao
    Liu, Xiaojun
    Fang, Guangyou
    REMOTE SENSING, 2023, 15 (19)
  • [36] 3-D Synthetic Imaging Using 128-Channel 2-D Sparse CMUT Array
    Choi, Won Young
    Kwak, Yun Sang
    Park, Kwan Kyu
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [37] A Spatial Multitarget Ultrasound Neuromodulation System Using High-Powered 2-D Array Transducer
    Zhuang, Xiaopeng
    He, Jiaru
    Wu, Junwei
    Ji, Xuanrong
    Chen, Yan
    Yuan, Maodan
    Zeng, Lvming
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (03) : 998 - 1007
  • [38] 3D ultrasound imaging in frequency domain with 1D array transducer
    Han, Zhihui
    Peng, Hu
    Lu, Putian
    ULTRASONICS, 2017, 76 : 28 - 34
  • [39] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Emmanuel Roux
    François Varray
    Lorena Petrusca
    Christian Cachard
    Piero Tortoli
    Hervé Liebgott
    Scientific Reports, 8
  • [40] Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
    Roux, Emmanuel
    Varray, Francois
    Petrusca, Lorena
    Cachard, Christian
    Tortoli, Piero
    Liebgott, Herve
    SCIENTIFIC REPORTS, 2018, 8