Microwave-assisted sample preparation of Hungarian raw propolis in quartz vessels and element analysis by ICP-OES and ICP-MS for geographical identification

被引:6
|
作者
Soos, Aron [1 ]
Bodi, Eva [1 ]
Varallyay, Szilvia [1 ]
Molnar, Szabolcs [2 ]
Kovacs, Bela [1 ]
机构
[1] Univ Debrecen, Inst Food Sci, Boszormenyi Str 138, H-4032 Debrecen, Hungary
[2] Eszterhazy Karoly Univ, Food & Wine Res Ctr, Leanyka Str 6, H-3300 Eger, Hungary
关键词
Microwave-assisted digestion; Sample preparation; Element analysis; Propolis; Geographical identification; SINGLE REACTION CHAMBER; DIFFERENT REGIONS; BOTANICAL ORIGIN; TOXIC ELEMENTS; WET DIGESTION; GREEN; CHEMISTRY; HONEYBEES; PRODUCTS;
D O I
10.1016/j.talanta.2021.122613
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the aims of this study was to improve the sample throughput of a microwave-assisted closed vessel digestion system by using small quartz vials in polytetrafluomethylene (PTFE) vessels for the sample preparation of raw propolis samples in small amounts. The digested samples were measured by inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS) analyzing 36 elements. Limit of detection was low enough to measure all the elements, with the exception of La, in all raw pmpolis samples. There were no cross-contamination between the quartz vials, therefore independent samples can be prepared in the same PTFE vessel. Accuracy of the method was checked by spike recoveries and by analyzing BCR 189 wholemeal flour and two plant samples from a collaborative study. The means of RSDs were 5.3%-14.4% in the case of measured elements. The sample throughput was increased by three times using quartz vials in PFTE vessels besides matching with the requirements of green chemistry. Another goal was the characterization of the element content and thereby geographical identification of Hungarian raw propolis. In total, 252 samples were analyzed and their statistical characteristics were described. We cannot find globally such results of pmpolis element content, which is representing one country and with such a number of elements and samples. All the elements have positive skew and positive kurtosis. Concentration range is above two orders of magnitude in the case of Ba, Zn, V, Cr, Ni, Cd and Eu elements. The decimal logarithm of element concentrations was used for geographical identification of raw pmpolis samples originating from seven regions of Hungary by linear discriminant analysis (LDA). Grouping of the samples of the Northern Great Plain was the most effective with 96.3% and 77.8% based on the original method and the cross validation, respectively. The same indicators for all the groups are 76.6% and 61.5%.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Exploring the Potential of Sewage Sludge as Agricultural Fertilizer: Determination of Heavy Metals and Nutrients by Microwave-Assisted Digestion Followed by ICP-OES Analysis
    Rocha, Filipe
    Alves, Arminda
    Homem, Vera
    JOURNAL OF CHEMICAL EDUCATION, 2022, 99 (09) : 3218 - 3226
  • [42] Simultaneous Determination of REEs in Coal Samples Using the Combination of Microwave-Assisted Ashing and Ultrasound-Assisted Extraction Methods Followed by ICP-OES Analysis
    Zuma, Mceliseni C.
    Nomngongo, Philiswa N.
    Mketo, Nomvano
    MINERALS, 2021, 11 (10)
  • [43] Evaluating the total gold concentration in metallic nanoparticles with a high content of organic matter through microwave-assisted decomposition platform and plasma-based spectrometric techniques (ICP-MS and ICP OES)
    Godoy, Naiara, V
    Galazzi, Rodrigo M.
    Chacon-Madrid, Katherine
    Arruda, Marco A. Z.
    Mazali, Italo O.
    TALANTA, 2021, 224
  • [44] Multi-element analysis of Tinishu Akaki River sediment, Ethiopia, by ICP-MS after microwave assisted digestion
    Melaku, S.
    Wondimu, T.
    Dams, R.
    Moens, L.
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2005, 50 (01): : 31 - 40
  • [45] A new sample preparation approach based on microwave-induced combustion in disposable vessels for Ni and V determination by ICP-MS in crude oil
    Mandlate, Jaime S.
    Brudi, Leticia C.
    Henn, Alessandra S.
    Becker, Luana C.
    Flores, Erico M. M.
    Duarte, Fabio A.
    TALANTA, 2025, 285
  • [46] Analysis of heavy metal distribution in superficial estuarine sediments (estuary of Bilbao, Basque Country) by open-focused microwave-assisted extraction and ICP-OES
    Landajo, A
    Arana, G
    de Diego, A
    Etxebarria, N
    Zuloaga, O
    Amouroux, D
    CHEMOSPHERE, 2004, 56 (11) : 1033 - 1041
  • [47] Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion
    Heilmann, J
    Boulyga, SF
    Heumann, KG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (02) : 190 - 197
  • [48] Microwave-assisted extraction based on emulsion breaking with natural deep eutectic solvent for vegetable oil sample preparation prior to elemental determination by ICP OES
    Costa, Floriatan Santos
    Moreira, Luana Santos
    Ludovico, Leticia Lima
    Volpe, Jaqueline
    de Oliveira, Ana Claudia
    dos Santos, Mayara Padovan
    da Silva, Erik Galvo Paranhos
    Souto, Denio Emanuel Pires
    Grassi, Marco Tadeu
    Gonzalez, Mario Henrique
    Amaral, Clarice D. B.
    TALANTA, 2024, 266
  • [49] Microwave-assisted digestion using diluted acids for toxic element determination in medicinal plants by ICP-MS in compliance with United States pharmacopeia requirements
    Muller, Aline L. H.
    Muller, Edson I.
    Barin, Juliano S.
    Flores, Erico M. M.
    ANALYTICAL METHODS, 2015, 7 (12) : 5218 - 5225
  • [50] Elemental fingerprinting based on ICP-MS/OES and machine learning: Sample digestion-free and standard-free strategy for geographical origin identification of Chinese liquor
    Zeng, Wen
    Xiong, Qing
    Lin, Tao
    Jiang, Xiaoming
    Hou, Xiandeng
    MICROCHEMICAL JOURNAL, 2024, 207