Verification of IMRT dose distributions using a water beam imaging system

被引:0
|
作者
Li, JS [1 ]
Ozhasoglu, C [1 ]
Deng, J [1 ]
Boyer, AL [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
IMRT; quality assurance (QA); dosimetry; Monte Carlo; water beam imaging system (WBIS);
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A water beam imaging system (WBIS) was developed and used to verify dose distributions for intensity modulated radiotherapy (IMRT) using dynamic multileaf collimator (MLC). The WBIS consists of a water container, a scintillator screen, a charge-coupled device (CCD) camera, and a portable personal computer (Wellhofer Dosimetrie, Schwarzenbruck, Germany). The scintillation image is captured by the CCD camera. The pixel value in this image indicates the dose value in the scintillation screen. The verification is performed by comparing the WBIS image achieved from the measurement with dose distribution from the IMRT plan. Because of Light scattering in the WBIS the image is blurred. An iterative reconstruction algorithm is proposed to remove the blurring effect of light scattering. From the measured image of a 10 cm x 10 cm x-ray beam and the simulation result of the dose distribution using the Monte Carlo method, the blur function can be achieved. Based on this function, the proposed algorithm is applied to reconstruct the true dose distribution for an IMRT plan from the measured WBIS image. The reconstructed dose distributions are compared with Monte Carlo simulation results. Reasonable agreement can be observed from the comparison. The proposed approach makes it possible to carry out real-time quality assurance tasks for IMRT dose verification.
引用
收藏
页码:1158 / 1161
页数:4
相关论文
共 50 条
  • [41] ANALYSIS OF 10 MV ELEKTA PRECISE BEAM MODELLING DATA FOR THE COMPASS® DOSE CALCULATION AND VERIFICATION SYSTEM FOR IMRT.
    Ausma, A. H.
    Arends, M.
    Birkner, M.
    Visscher, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S575 - S576
  • [42] APPLICATION OF TWO-DIMENSIONAL MatriXX OF DETECTORS TO VERIFICATION OF TOTAL DOSE DISTRIBUTIONS IN IMRT TECHNIQUES
    Chelminski, K.
    Bulski, W.
    Sobotka, P.
    Rostkowska, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : XX - XXI
  • [43] In vivo surface dose verification of skin treatment using helical IMRT
    Corradini, N.
    Presilla, S.
    Schombourg, K.
    Ballerini, G.
    Franzetti-Pellanda, A.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 750 - 750
  • [44] ABSOLUTE DOSE VERIFICATION OF DIFFERENT IMRT TREATMENTS USING TLD DOSIMETERS
    Lopez-Vilanova, N.
    Sanchez-Reyes, A.
    Vila, A.
    Duch, M. A.
    Rodriguez Garcia, A.
    Loscos, S.
    Ginjaume, M.
    Pedro, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S380 - S380
  • [45] Dose verification of helical tomotherapy IMRT treatment using ArcCHECK device
    Rodriguez Romero, R.
    Sanchez Rubio, P.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (10) : 682 - 682
  • [46] 3D in vivo dose verification of an entire IMRT treatment using an EPID and Cone-beam CT
    McDermott, L.
    Wending, M.
    Mans, A.
    de Jong, R.
    Sonke, J.
    van Herk, M.
    Mijnheer, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S98 - S98
  • [47] Accurate in water electron beam dose measurements using polarization imaging
    Cloutier, E.
    Beaulieu, L.
    Archambault, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S97 - S98
  • [48] IMRT verification with a camera-based electronic portal imaging system
    Partridge, M
    Symonds-Tayler, JRN
    Evans, PM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12): : N183 - N196
  • [49] Evaluation of a 2D array planar dose verification system for IMRT dose delivery
    Malhotra, H. K.
    Liu, J.
    Tran, T.
    Podgorsak, M. B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S729 - S729
  • [50] In-Beam PET Imaging in Carbon Therapy for Dose Verification
    Li, Zhongxing
    Fan, Yaming
    Dong, Ming
    Tong, Linge
    Zhao, Liang
    Yin, Yongzhi
    Chen, Ximeng
    [J]. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (01) : 61 - 67