Verification of IMRT dose distributions using a water beam imaging system

被引:0
|
作者
Li, JS [1 ]
Ozhasoglu, C [1 ]
Deng, J [1 ]
Boyer, AL [1 ]
Ma, CM [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
关键词
IMRT; quality assurance (QA); dosimetry; Monte Carlo; water beam imaging system (WBIS);
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A water beam imaging system (WBIS) was developed and used to verify dose distributions for intensity modulated radiotherapy (IMRT) using dynamic multileaf collimator (MLC). The WBIS consists of a water container, a scintillator screen, a charge-coupled device (CCD) camera, and a portable personal computer (Wellhofer Dosimetrie, Schwarzenbruck, Germany). The scintillation image is captured by the CCD camera. The pixel value in this image indicates the dose value in the scintillation screen. The verification is performed by comparing the WBIS image achieved from the measurement with dose distribution from the IMRT plan. Because of Light scattering in the WBIS the image is blurred. An iterative reconstruction algorithm is proposed to remove the blurring effect of light scattering. From the measured image of a 10 cm x 10 cm x-ray beam and the simulation result of the dose distribution using the Monte Carlo method, the blur function can be achieved. Based on this function, the proposed algorithm is applied to reconstruct the true dose distribution for an IMRT plan from the measured WBIS image. The reconstructed dose distributions are compared with Monte Carlo simulation results. Reasonable agreement can be observed from the comparison. The proposed approach makes it possible to carry out real-time quality assurance tasks for IMRT dose verification.
引用
收藏
页码:1158 / 1161
页数:4
相关论文
共 50 条
  • [21] Analyzing the accuracy of IMRT dose distributions using a dose uncertainty model
    Jin, H
    Chung, H
    Palta, J
    Suh, T
    Kim, S
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2168 - 2168
  • [22] Incorporation of functional imaging data in the evaluation of IMRT dose distributions using the generalized concept of EUD
    Miften, M
    Su, M
    Das, S
    Marks, L
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1394 - 1394
  • [23] IMRT verification in clinical routine using portal imaging
    Vetterli, D
    Born, E
    Cossmann, P
    Mini, R
    Manser, P
    Rüegsegger, P
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1271 - 1271
  • [24] A TAR-based system for automatic IMRT dose verification
    Morrill, S
    Bayouth, J
    Wendt, D
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1417 - 1417
  • [25] An IMRT dose distribution study using commercial verification software
    Liu G.
    Fernando W.
    Grace M.
    Rykers K.
    [J]. Australasian Physical and Engineering Sciences in Medicine, 2004, 27 (03): : 129 - 135
  • [26] Susceptibility of IMRT dose distributions to deformable organ motion and the impact of beam smoothing
    Coolens, C
    Evans, PM
    Seco, J
    Webb, S
    Blackall, J
    Rietzel, E
    Chen, GTY
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S176 - S177
  • [27] Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code
    Medical Physics Department, S. Bortolo Hospital, 36100 Vicenza, Italy
    [J]. 1600, 144-157 (February 1, 2003):
  • [28] Surface dose prediction and verification for IMRT plans using line dose profiles
    Berg, R
    Klash, S
    Gossman, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S590 - S590
  • [29] Dose Verification for IMRT DMLC Delivery Using An EPID Imager
    Zhao, B.
    Yang, Y.
    Li, T.
    Li, X.
    Heron, D.
    Huq, M.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [30] Dose verification of an IMRT treatment planning system with the BEAM EGS4-based Monte Carlo code
    Francescon, P
    Cora, S
    Chiovati, P
    [J]. MEDICAL PHYSICS, 2003, 30 (02) : 144 - 157