Non-invasive intraocular pressure monitoring with a contact lens engineered with a nanostructured polymeric sensing film

被引:47
|
作者
Laukhin, Vladimir [1 ,2 ]
Sanchez, Irene [3 ,4 ]
Moya, Ana [4 ,5 ]
Laukhina, Elena [1 ,4 ]
Martin, Raul [3 ,4 ,6 ]
Ussa, Fernando [3 ]
Rovira, Concepcio [1 ,4 ]
Guimera, Anton [4 ,5 ]
Villa, Rosa [4 ,5 ]
Aguilo, Jordi [4 ,5 ]
Pastor, Jose-Carlos [3 ]
Veciana, Jaume [1 ,4 ]
机构
[1] CSIC, Inst Ciencia Mat Barcelona, E-08193 Barcelona, Spain
[2] ICREA, Catalunya, Spain
[3] Univ Valladolid, IOBA Eye Inst, Valladolid, Spain
[4] Networking Res Ctr Bioengn Biomat & Nanomed CIBER, Zaragoza, Spain
[5] CSIC, Inst Microelect Barcelona IMB CNM, E-08193 Barcelona, Spain
[6] Univ Valladolid, Sch Optometry, Dept Phys TAO, Valladolid, Spain
关键词
Glaucoma; Pressure sensor; Nanostructured polymer composite; Contact lens; Intraocular pressure; In vitro experiments; OPEN-ANGLE GLAUCOMA; CORNEAL CURVATURE;
D O I
10.1016/j.sna.2011.05.021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new prototype of contact lens sensor (CLS) for monitoring the intraocular pressure (IOP) variations in a non-invasive way has been developed. The CLS has as a key element a thin film, comprised of a new all-organic flexible highly piezo-resistive sensor, that is glued to the central hole of a doughnut-shaped hard contact lens. A few CLSs were fabricated and tested with an eye phantom and with enucleated pig eyes by means of applying pressure with a low pressure transducer and recording the electrical changes in the sensor with a portable recorder. The developed CLSs are biocompatible permitting to transmit the changes in cornea curvature induced by the IOP variations, directly to the flexible conducting polymeric sensor embedded in the CL The electrical response of the CLS to pressure changes reveals a high linearity as well as a good reproducibility having the proper sensitivity to perform continuous monitoring of LOP. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [31] Non-contact Non-invasive Heart and Respiration Rates Monitoring with MIMO Radar Sensing
    Liu, Qiwei
    Guo, Hanqing
    Xu, Junhong
    Kageza, Aron
    AlQarni, Saeed
    Wu, Shaoen
    Wang, Honggang
    2018 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM), 2018,
  • [32] Comparison of invasive and non-invasive intracranial pressure monitoring
    Hamarat, Y.
    Deimantavicius, M.
    Zakelis, R.
    Bartusis, L.
    Preiksaitis, A.
    Ragauska, A.
    EUROPEAN JOURNAL OF NEUROLOGY, 2018, 25 : 60 - 60
  • [33] Soft wearable contact lens sensor for continuous intraocular pressure monitoring
    Chen, Guo-Zhen
    Chan, Ion-Seng
    Leung, Leo K. K.
    Lam, David C. C.
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (09) : 1134 - 1139
  • [34] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Joohee Kim
    Jihun Park
    Young-Geun Park
    Eunkyung Cha
    Minjae Ku
    Hyeon Seok An
    Kyoung-Pil Lee
    Man-Il Huh
    Junmo Kim
    Taek-Soo Kim
    Dai Woo Kim
    Hong Kyun Kim
    Jang-Ung Park
    Nature Biomedical Engineering, 2021, 5 : 772 - 782
  • [35] Design of wireless contact-lens antenna for intraocular pressure monitoring
    Priya, L.
    Vijitha, J.
    Alagappan, M.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2019, 31 (03) : 315 - 323
  • [36] Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability
    Yang, Huan
    Zhu, Hengtian
    Liu, Hanwen
    Mao, Zhengyi
    Luo, Junxian
    Zhu, Shugeng
    Hu, Zizhong
    Yuan, Songtao
    Xu, Fei
    ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (34)
  • [37] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Kim, Joohee
    Park, Jihun
    Park, Young-Geun
    Cha, Eunkyung
    Ku, Minjae
    An, Hyeon Seok
    Lee, Kyoung-Pil
    Huh, Man-Il
    Kim, Junmo
    Kim, Taek-Soo
    Kim, Dai Woo
    Kim, Hong Kyun
    Park, Jang-Ung
    NATURE BIOMEDICAL ENGINEERING, 2021, 5 (07) : 772 - 782
  • [38] Non-invasive arterial pressure monitoring revisited
    Frederic Michard
    Daniel I. Sessler
    Bernd Saugel
    Intensive Care Medicine, 2018, 44 : 2213 - 2215
  • [39] Non-invasive blood pressure monitoring in man
    Portaluppi, F
    PATHOLOGIE BIOLOGIE, 1996, 44 (03): : 196 - 200
  • [40] Non-invasive arterial pressure monitoring revisited
    Michard, Frederic
    Sessler, Daniel I.
    Saugel, Bernd
    INTENSIVE CARE MEDICINE, 2018, 44 (12) : 2213 - 2215