Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study

被引:6
|
作者
Zhang, Chu-Nan [1 ,2 ,3 ,4 ]
Zhu, Yu [1 ,2 ,3 ,4 ]
Fan, Lin-Feng [5 ]
Zhang, Xiao [1 ,2 ,3 ,4 ]
Jiang, Yin-Hua [6 ]
Gu, Ying-Xin [1 ,2 ,3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Coll Stomatol, Dept Implant Dent,Sch Med, Shanghai, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[3] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[4] Shanghai Res Inst Stomatol, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Coll Stomatol, Dept Radiol,Sch Med, Shanghai, Peoples R China
[6] Wenzhou Med Univ, Lishui Peoples Hosp 6, Dept Oral & Maxillofacial Implantol, Lishui, Peoples R China
关键词
Cone beam computed tomography; Dental implants; Periapical radiography; Peri-implant bone defect; FIELD-OF-VIEW; DENTAL IMPLANTS; ACCURACY; FENESTRATION; LEVEL;
D O I
10.1016/j.jds.2020.10.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: Information regarding agreements between periapical radio-graph (PA) and cone beam computed tomography (CBCT) in detecting peri-implant defect is still scarce. The aim of this clinical study was to compare agreements between PA and CBCT in detecting peri-implant bone defect. Materials and methods: This retrospective clinical study enrolled 32 patients with both PA and CBCT filmed right after implant placement. Four modalities were used for film reading: PA1 (orig-inal), PA2 (enhanced brightness/contrast), CBCT1 (selected axial and mesial-distal direction im-ages) and CBCT2 (all data with software). 2 experienced and 2 inexperienced observers scored all films. Intra-and inter-observer agreements were estimated with Cohen's kappa coefficient. Cate-gorized agreements were compared and differences among four modalities were calculated. Results: Agreements of PA were better than CBCT when detecting peri-implant bone defects in inter-observer agreements (median kappa 0.471 vs. 0.192; p = 0.016). Moreover, agreements in experienced observers were better than inexperienced observers (median kappa 0.883 vs. 0.567; p < 0.001). There was significant difference among four modalities except for experienced observer 2 (p = 0.218). Conclusion: Agreements of PA are better than CBCT when detecting peri-implant bone defects, especially for inter-observer agreements. Experienced observers are more consistent in assess-ment than inexperienced ones. & ordf; 2020 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:948 / 956
页数:9
相关论文
共 50 条
  • [31] Comprehensive peri-implant tissue evaluation with ultrasonography and cone-beam computed tomography: A pilot study
    Siqueira, Rafael
    Sinjab, Khaled
    Pan, Ying-Chun
    Soki, Fabiana
    Chan, Hsun-Liang
    Kripfgans, Oliver
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (07) : 777 - 785
  • [32] Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard
    Corpas, Livia dos Santos
    Jacobs, Reinhilde
    Quirynen, Marc
    Huang, Yan
    Naert, Ignace
    Duyck, Joke
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 492 - 499
  • [33] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Mehmet Hakan Kurt
    Nilsun Bağış
    Cengiz Evli
    Cemal Atakan
    Kaan Orhan
    International Journal of Implant Dentistry, 6
  • [34] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Kurt, Mehmet Hakan
    Bagis, Nilsun
    Evli, Cengiz
    Atakan, Cemal
    Orhan, Kaan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [35] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography—is this correct?
    Siamak Sabour
    Elahe Vahid Dastjerdi
    Maryam Moezizadeh
    Clinical Oral Investigations, 2013, 17 : 1785 - 1785
  • [36] A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations
    Haghanifar, Sina
    Moudi, Ehsan
    Mesgarani, Abbas
    Bijani, Ali
    Abbaszadeh, Naghi
    IMAGING SCIENCE IN DENTISTRY, 2014, 44 (02) : 115 - 119
  • [37] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography-is this correct?
    Sabour, Siamak
    Dastjerdi, Elahe Vahid
    Moezizadeh, Maryam
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1785 - 1785
  • [38] More about accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Dongyun Wang
    Andreas Künzel
    Vladimir Golubovic
    Ilya Mihatovic
    Gordon John
    Zhuofan Chen
    Jürgen Becker
    Frank Schwarz
    Clinical Oral Investigations, 2013, 17 : 1787 - 1788
  • [39] Higher Resolution in Cone Beam Computed Tomography Is Accompanied by Improved Bone Detection in Peri-implant Bone Despite Metal Artifact Presence
    Kerkfeld, Valentin
    Meyer, Ulrich
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1331 - 1338
  • [40] More about accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Wang, Dongyun
    Kuenzel, Andreas
    Golubovic, Vladimir
    Mihatovic, Ilya
    John, Gordon
    Chen, Zhuofan
    Becker, Juergen
    Schwarz, Frank
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1787 - 1788