Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study

被引:6
|
作者
Zhang, Chu-Nan [1 ,2 ,3 ,4 ]
Zhu, Yu [1 ,2 ,3 ,4 ]
Fan, Lin-Feng [5 ]
Zhang, Xiao [1 ,2 ,3 ,4 ]
Jiang, Yin-Hua [6 ]
Gu, Ying-Xin [1 ,2 ,3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Coll Stomatol, Dept Implant Dent,Sch Med, Shanghai, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[3] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[4] Shanghai Res Inst Stomatol, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Coll Stomatol, Dept Radiol,Sch Med, Shanghai, Peoples R China
[6] Wenzhou Med Univ, Lishui Peoples Hosp 6, Dept Oral & Maxillofacial Implantol, Lishui, Peoples R China
关键词
Cone beam computed tomography; Dental implants; Periapical radiography; Peri-implant bone defect; FIELD-OF-VIEW; DENTAL IMPLANTS; ACCURACY; FENESTRATION; LEVEL;
D O I
10.1016/j.jds.2020.10.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: Information regarding agreements between periapical radio-graph (PA) and cone beam computed tomography (CBCT) in detecting peri-implant defect is still scarce. The aim of this clinical study was to compare agreements between PA and CBCT in detecting peri-implant bone defect. Materials and methods: This retrospective clinical study enrolled 32 patients with both PA and CBCT filmed right after implant placement. Four modalities were used for film reading: PA1 (orig-inal), PA2 (enhanced brightness/contrast), CBCT1 (selected axial and mesial-distal direction im-ages) and CBCT2 (all data with software). 2 experienced and 2 inexperienced observers scored all films. Intra-and inter-observer agreements were estimated with Cohen's kappa coefficient. Cate-gorized agreements were compared and differences among four modalities were calculated. Results: Agreements of PA were better than CBCT when detecting peri-implant bone defects in inter-observer agreements (median kappa 0.471 vs. 0.192; p = 0.016). Moreover, agreements in experienced observers were better than inexperienced observers (median kappa 0.883 vs. 0.567; p < 0.001). There was significant difference among four modalities except for experienced observer 2 (p = 0.218). Conclusion: Agreements of PA are better than CBCT when detecting peri-implant bone defects, especially for inter-observer agreements. Experienced observers are more consistent in assess-ment than inexperienced ones. & ordf; 2020 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:948 / 956
页数:9
相关论文
共 50 条
  • [21] Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
    Magat, Guldane
    Oncu, Elif
    Ozcan, Sevgi
    Orhan, Kaan
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2022, 48 (01) : 41 - 49
  • [22] Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs
    Fienitz, Tim
    Schwarz, Frank
    Ritter, Lutz
    Dreiseidler, Timo
    Becker, Juergen
    Rothamel, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 882 - 887
  • [23] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Wang, Dongyun
    Kuenzel, Andreas
    Golubovic, Vladimir
    Mihatovic, Ilya
    John, Gordon
    Chen, Zhuofan
    Becker, Juergen
    Schwarz, Frank
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (06) : 1601 - 1609
  • [24] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Alaa Shafiek Nomier
    Yousria Salah El-Din Gaweesh
    Maha R. Taalab
    Shaimaa Abu El Sadat
    BMC Oral Health, 22
  • [25] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Dongyun Wang
    Andreas Künzel
    Vladimir Golubovic
    Ilya Mihatovic
    Gordon John
    Zhuofan Chen
    Jürgen Becker
    Frank Schwarz
    Clinical Oral Investigations, 2013, 17 : 1601 - 1609
  • [26] Efficacy of low-dose cone beam computed tomography and metal artifact reduction tool for assessment of peri-implant bone defects: an in vitro study
    Nomier, Alaa Shafiek
    Gaweesh, Yousria Salah El-Din
    Taalab, Maha R. R.
    El Sadat, Shaimaa Abu
    BMC ORAL HEALTH, 2022, 22 (01)
  • [27] Effect of field of view in the detection of chemically created peri-implant bone defects in bovine ribs using cone beam computed tomography: an in vitro study
    Pinheiro, Lucas Rodrigues
    Gaia, Bruno Felipe
    Oliveira de Sales, Marcelo Augusto
    Umetsubo, Otavio Shoiti
    Santos, Oseas, Jr.
    Paraiso Cavalcanti, Marcelo Gusmao
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2015, 120 (01): : 69 - 77
  • [28] Zirconia implants interfere with the evaluation of peri-implant bone defects in cone beam computed tomography (CBCT) images even with artifact reduction, a pilot study
    Kuusisto, Niina
    Abushahba, Faleh
    Syrjanen, Stina
    Huumonen, Sisko
    Vallittu, Pekka
    Narhi, Timo
    DENTOMAXILLOFACIAL RADIOLOGY, 2023, 52 (08)
  • [29] Measuring peri-implant bone lesions using low-dose cone-beam computed tomography
    Leisner, Laura Christine
    Tasaka, Akinori
    Trebing, Charlotte Theresa
    Hilgenfeld, Tim
    Kosinski, Matthias Adalbert
    Kronsteiner, Dorothea
    Rammelsberg, Peter
    Schwindling, Franz Sebastian
    JOURNAL OF PROSTHODONTIC RESEARCH, 2022, 66 (02) : 326 - 332
  • [30] Comparison of Cone-Beam Computed Tomography and Periapical Radiography in Predicting Treatment Decision for Periapical Lesions: A Clinical Study
    Balasundaram, Ashok
    Shah, Punit
    Hoen, Michael M.
    Wheater, Michelle A.
    Bringas, Josef S.
    Gartner, Arnold
    Geist, James R.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012