Dynamic Control of a DFIG Wind Power Generation System to Mitigate Unbalanced Grid Voltage

被引:19
|
作者
Eltamaly, Ali M. [1 ,2 ,3 ]
Al-Saud, M. S. [1 ,4 ]
Abo-Khalil, Ahmed G. [5 ,6 ]
机构
[1] King Saud Univ, Saudi Elect Co Chair Power Syst Reliabil & Secur, Riyadh 11421, Saudi Arabia
[2] King Saud Univ, Sustainable Energy Technol Ctr, Riyadh 11421, Saudi Arabia
[3] Mansoura Univ, Elect Engn Dept, Mansoura 35516, Egypt
[4] King Saud Univ, Coll Engn, Elect Engn Dept, Riyadh 11421, Saudi Arabia
[5] Majmaah Univ, Coll Engn, Dept Elect Engn, Almajmaah 11952, Saudi Arabia
[6] Assiut Univ, Coll Engn, Dept Elect Engn, Assiut 71515, Egypt
来源
IEEE ACCESS | 2020年 / 8卷
关键词
Stators; Doubly fed induction generators; Rotors; Reactive power; Voltage control; Synchronization; DFIG; synchronization; MSF; unbalanced voltage; FED-INDUCTION-GENERATOR; ENERGY-CONVERSION SYSTEM; FREQUENCY; TURBINES; OPERATION; SUPPORT;
D O I
10.1109/ACCESS.2020.2976195
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an improved control strategy for a doubly-fed induction generator (DFIG) during unbalanced grid voltage conditions. The proposed strategy was applied in both synchronization and grid-connected conditions. The synchronization process is carried by controlling the extracted positive and negative sequence components of the stator q-axis voltage to follow the grid q-axis voltage. This strategy can be accomplished by controlling the positive and negative sequence components of the rotor d-axis current. By perturbing the rotor d-axis current, the stator EMF builds up and follows the grid voltage accurately. The stator frequency and the phase difference between the stator and grid voltage are compensated by adjusting the stator d-axis positive and negative voltage components to zero. After synchronization, the proposed control strategy focuses on regulating the average stator active and reactive power control by controlling the positive components of q and d-axis currents, respectively. The second target is to minimize the generator torque ripple by controlling the rotor negative sequence components. At the same time, the grid side converter is controlled to minimize the grid power pulsations to reduce the impact of the unbalanced grid voltage. This study focuses on enhancing the dynamics of DFIG during the unbalanced grid voltage by using Multivariable State Feedback (MSF) current controllers. Experiments are carried out to validate the performance improvement by using the proposed method. The simulation and experimental results showed superior performance of the proposed control strategy.
引用
收藏
页码:39091 / 39103
页数:13
相关论文
共 50 条
  • [41] Dynamic response of wind power generation based on DFIG under grid fault
    Guo, Jiahu
    Zhang, Luhua
    Cai, Xu
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2010, 31 (08): : 1023 - 1029
  • [42] Dynamic Response of Wind Power Generation Based on DFIG under Grid Fault
    Guo Jia-Hu
    Zhang Lu-hua
    Cai Xu
    [J]. 2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1443 - 1446
  • [43] Coordinated Control of the DFIG Wind Power Generating System Based on Series Grid Side Converter and Passivity-Based Controller Under Unbalanced Grid Voltage Conditions
    Qiming Cheng
    Xinqiao Ma
    Yinman Cheng
    [J]. Journal of Electrical Engineering & Technology, 2020, 15 : 2133 - 2143
  • [44] Coordinated Control of the DFIG Wind Power Generating System Based on Series Grid Side Converter and Passivity-Based Controller Under Unbalanced Grid Voltage Conditions
    Cheng, Qiming
    Ma, Xinqiao
    Cheng, Yinman
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2020, 15 (05) : 2133 - 2143
  • [45] Direct Power Control for DFIG under Unbalanced and Harmonically Distorted Grid Voltage in Stationary Frame
    Song, Yipeng
    Nian, Heng
    [J]. 2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1500 - 1506
  • [46] Control Strategy of Wind Power Converter Under Unbalanced Grid Voltage Condition
    Jiang, Chenhui
    Wang, Zhixin
    [J]. PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 615 - 621
  • [47] Control of DFIG-WT under unbalanced grid voltage conditions
    Luna, Alvaro
    Lima, Kleber
    Corcoles, Felipe
    Watanabe, Edson
    Rodriguez, Pedro
    Teodorescu, Remus
    [J]. 2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 774 - +
  • [48] Modeling and enhanced control of DFIG under unbalanced grid voltage conditions
    Hu, Jiabing
    He, Yikang
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (02) : 273 - 281
  • [49] Control of DFIG under unbalanced grid voltage conditions: A literature review
    Zeeshan, Abdul
    Sinha, Sunil Kumar
    [J]. 2016 2ND IEEE INTERNATIONAL CONFERENCE ON CONTROL, COMPUTING, COMMUNICATION AND MATERIALS (ICCCCM), 2016,
  • [50] Modularized Control Strategy and Performance Analysis of DFIG System Under Unbalanced and Harmonic Grid Voltage
    Song, Yipeng
    Nian, Heng
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 4831 - 4842