Dynamic Control of a DFIG Wind Power Generation System to Mitigate Unbalanced Grid Voltage

被引:19
|
作者
Eltamaly, Ali M. [1 ,2 ,3 ]
Al-Saud, M. S. [1 ,4 ]
Abo-Khalil, Ahmed G. [5 ,6 ]
机构
[1] King Saud Univ, Saudi Elect Co Chair Power Syst Reliabil & Secur, Riyadh 11421, Saudi Arabia
[2] King Saud Univ, Sustainable Energy Technol Ctr, Riyadh 11421, Saudi Arabia
[3] Mansoura Univ, Elect Engn Dept, Mansoura 35516, Egypt
[4] King Saud Univ, Coll Engn, Elect Engn Dept, Riyadh 11421, Saudi Arabia
[5] Majmaah Univ, Coll Engn, Dept Elect Engn, Almajmaah 11952, Saudi Arabia
[6] Assiut Univ, Coll Engn, Dept Elect Engn, Assiut 71515, Egypt
来源
IEEE ACCESS | 2020年 / 8卷
关键词
Stators; Doubly fed induction generators; Rotors; Reactive power; Voltage control; Synchronization; DFIG; synchronization; MSF; unbalanced voltage; FED-INDUCTION-GENERATOR; ENERGY-CONVERSION SYSTEM; FREQUENCY; TURBINES; OPERATION; SUPPORT;
D O I
10.1109/ACCESS.2020.2976195
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents an improved control strategy for a doubly-fed induction generator (DFIG) during unbalanced grid voltage conditions. The proposed strategy was applied in both synchronization and grid-connected conditions. The synchronization process is carried by controlling the extracted positive and negative sequence components of the stator q-axis voltage to follow the grid q-axis voltage. This strategy can be accomplished by controlling the positive and negative sequence components of the rotor d-axis current. By perturbing the rotor d-axis current, the stator EMF builds up and follows the grid voltage accurately. The stator frequency and the phase difference between the stator and grid voltage are compensated by adjusting the stator d-axis positive and negative voltage components to zero. After synchronization, the proposed control strategy focuses on regulating the average stator active and reactive power control by controlling the positive components of q and d-axis currents, respectively. The second target is to minimize the generator torque ripple by controlling the rotor negative sequence components. At the same time, the grid side converter is controlled to minimize the grid power pulsations to reduce the impact of the unbalanced grid voltage. This study focuses on enhancing the dynamics of DFIG during the unbalanced grid voltage by using Multivariable State Feedback (MSF) current controllers. Experiments are carried out to validate the performance improvement by using the proposed method. The simulation and experimental results showed superior performance of the proposed control strategy.
引用
收藏
页码:39091 / 39103
页数:13
相关论文
共 50 条
  • [21] Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions
    Jia-bing Hu
    Yi-kang He
    Lie Xu
    [J]. Journal of Zhejiang University-SCIENCE A, 2008, 9 : 1731 - 1740
  • [22] Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions
    Hu, Jia-bing
    He, Yi-kang
    Xu, Lie
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2008, 9 (12): : 1731 - 1740
  • [23] Dynamic Modeling and Improved Control of DFIG under Unbalanced and Distorted Grid Voltage Conditions
    Xu, Hailiang
    Hu, Jiabing
    Nian, Heng
    He, Yikang
    [J]. 2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 1579 - 1584
  • [24] Enhanced Control Strategies of Permanent Magnet Synchronous Wind Power Generation System under Unbalanced Grid Voltage Conditions
    Wang, Zhan
    Nian, Heng
    Hu, Jiabing
    [J]. 2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [25] Modeling and improvement of direct power control of DFIG under unbalanced grid voltage condition
    Zandzadeh, Mohammad Jafar
    Vahedi, Abolfazl
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 59 : 58 - 65
  • [26] Current-based direct power control of a DFIG under unbalanced grid voltage
    Farshadnia, Mohammad
    Taher, Seyed Abbas
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 571 - 582
  • [27] Improved Power Control of Photovoltaic Generation System under Unbalanced Grid Voltage Conditions
    Chen, Xu
    Zhang, Yongjun
    Yang, Jiwang
    Chen, Yong
    Wang, Qianggang
    Zhou, Niancheng
    [J]. 2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [28] Small Signal Modeling and Stability Analysis of a DFIG Based Wind Power System under Unbalanced Grid Voltage Condition
    Wang, Tao
    Nian, Heng
    [J]. 2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 2625 - 2630
  • [29] Improved power control of photovoltaic generation system under unbalanced grid voltage conditions
    [J]. Wang, Q., 1600, Chinese Society for Electrical Engineering (33):
  • [30] Variable Speed Control of DFIG-Wind Turbine under unbalanced grid voltage conditions
    Majdoub, Youssef
    Abbou, Ahmed
    Akherraz, Mohamed
    El Akhrif, Rachid
    Bakouri, Anass
    [J]. PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 1224 - 1229