Left Ventricular Filling Pressures Contribute to Exercise Limitation in Patients with Continuous Flow Left Ventricular Assist Devices

被引:5
|
作者
Koshy, Aaron [1 ]
Bouzas-Cruz, Noelia [1 ,2 ]
Okwose, Nduka C. [3 ]
Fernandez, Oscar Gonzalez [1 ]
Green, Thomas [1 ]
Woods, Andrew [1 ]
Robinson-Smith, Nicola [1 ]
Tovey, Sian [1 ]
McDiarmid, Adam [1 ]
Parry, Gareth [1 ]
Schueler, Stephan [1 ]
Jakovljevic, Djordje G. [3 ]
MacGowan, Guy A. [1 ,3 ]
机构
[1] Freeman Rd Hosp, Dept Cardiol & Cardiothorac Surg, Newcastle Upon Tyne, Tyne & Wear, England
[2] Univ Santiago Compostela, Galicia, Spain
[3] Newcastle Univ, Inst Cellular Med & Genet Med, Newcastle Upon Tyne, Tyne & Wear, England
关键词
exercise capacity; left ventricular assist device; hemodynamics; PUMP SPEED; CARDIAC-OUTPUT; HEART-FAILURE; DOUBLE-BLIND; IMPACT; PERFORMANCE; AFTERLOAD; PRELOAD; SUPPORT;
D O I
10.1097/MAT.0000000000001073
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We sought to determine hemodynamic mechanisms of exercise intolerance in a group of patients with the HeartWare ventricular assist device (VAD) compared to a group of heart failure patients. Twenty VAD and 22 heart failure patients underwent symptom-limited active straight leg raising exercise during right heart catheterization with thermodilution (TD), and upright cycling cardiopulmonary stress testing with cardiac output measurement by inert gas rebreathing (IGR) method. The TD and IGR exercise cardiac indexes were higher in VAD compared with heart failure group (both P < 0.05), although there was only a borderline increase in peak exercise oxygen consumption (VO2) (P = 0.06). Baseline and exercise right heart catheterization pressures were not significantly different between the two groups. The only significant independent predictors of peak VO2 in the heart failure group were exercise heart rate and cardiac index (both P < 0.05). In contrast, for the VAD group only, resting pulmonary arterial wedge and pulmonary arterial mean pressures were independently related to peak VO2 (both P < 0.05). Thus, in heart failure, exercise cardiac index is an important limitation to exercise capacity, and VADs increase exercise cardiac index. However, in VAD patients, this only produces limited benefits as increased pulmonary and pulmonary wedge pressures limit increases in exercise capacity.
引用
收藏
页码:247 / 252
页数:6
相关论文
共 50 条
  • [21] Continuous flow left ventricular assist devices: Dare to compare
    Goldstein, Daniel J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 151 (01): : 190 - 191
  • [22] Hematologic Effects of Continuous Flow Left Ventricular Assist Devices
    Mark S. Slaughter
    Journal of Cardiovascular Translational Research, 2010, 3 : 618 - 624
  • [23] Hematologic Effects of Continuous Flow Left Ventricular Assist Devices
    Slaughter, Mark S.
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2010, 3 (06) : 618 - 624
  • [24] The Physiology of Continuous-Flow Left Ventricular Assist Devices
    Lim, Hoong Sern
    Howell, Neil
    Ranasinghe, Aaron
    JOURNAL OF CARDIAC FAILURE, 2017, 23 (02) : 169 - 180
  • [25] Hemodynamic and exercise performance with Pulsatile and continuous-flow left ventricular assist devices
    Haft, Jonathan
    Armstrong, William
    Dyke, David B.
    Aaronson, Keith D.
    Koelling, Todd M.
    Farrar, David J.
    Pagani, Francis D.
    CIRCULATION, 2007, 116 (11) : I8 - I15
  • [26] Management of hypertension in patients supported with continuous flow left ventricular assist devices
    Krishnarao, Krithika
    Krim, Selim R.
    CURRENT OPINION IN CARDIOLOGY, 2023, 38 (04) : 281 - 286
  • [27] Platelet activation in patients supported by continuous flow left ventricular assist devices
    Slaughter, M. S.
    Sobieski, M. A.
    Graham, J. D.
    Horrell, T.
    Pappas, P. S.
    Tatooles, A. J.
    Rao, G. H. R.
    Stein, R.
    Brindiese, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (02): : S183 - S183
  • [28] Safety of enoxaparin in patients implanted with continuous flow left ventricular assist devices
    Klosko, Rachel C.
    Whitson, Bryan
    Lampert, Brent
    Mclaughlin, Eric
    Orzel, Libby
    ARTIFICIAL ORGANS, 2024,
  • [29] Effect of Continuous Flow Left Ventricular Assist Devices on Left Ventricular Size and Severity of Mitral Regurgitation
    Mandras, S. A.
    Joseph, S.
    Saeed, I. M.
    Guthrie, T. J.
    Arnold, S. V.
    Wang, I. -W.
    Moazami, N.
    Ewald, G. A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (02): : S133 - S134
  • [30] Continuous flow centrifugal left ventricular assist devices in patients with hypertrophic cardiomyopathy
    Muthiah, K.
    Robson, D.
    Macdonald, P.
    Keogh, A.
    Kotlyar, E.
    Spratt, P.
    Dhital, K.
    Granger, E.
    Jansz, P.
    Hayward, C.
    EUROPEAN HEART JOURNAL, 2012, 33 : 507 - 507