Filtered back-projection reconstruction for attenuation proton CT along most likely paths

被引:14
|
作者
Quinones, C. T. [1 ]
Letang, J. M. [1 ]
Rit, S. [1 ]
机构
[1] Univ Lyon 1, Ctr Leon Berard, CREATIS, CNRS,UMR5220,Inserm,U1206,INSA Lyon, F-69622 Villeurbanne, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 09期
关键词
proton computed tomography; proton CT; filtered back-projection; most likely path; inelastic cross-section; attenuation; MULTIPLE COULOMB SCATTERING; COMPUTED-TOMOGRAPHY; STOPPING-POWER; MONTE-CARLO; RANGE UNCERTAINTIES; SPATIAL-RESOLUTION; CONCEPTUAL DESIGN; RADIOGRAPHY; THERAPY; RADIOTHERAPY;
D O I
10.1088/0031-9155/61/9/3258
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work investigates the attenuation of a proton beam to reconstruct the map of the linear attenuation coefficient of a material which is mainly caused by the inelastic interactions of protons with matter. Attenuation proton computed tomography (pCT) suffers from a poor spatial resolution due to multiple Coulomb scattering (MCS) of protons in matter, similarly to the conventional energy-loss pCT. We therefore adapted a recent filtered back-projection algorithm along the most likely path (MLP) of protons for energy-loss pCT (Rit et al 2013) to attenuation pCT assuming a pCT scanner that can track the position and the direction of protons before and after the scanned object. Monte Carlo simulations of pCT acquisitions of density and spatial resolution phantoms were performed to characterize the new algorithm using Geant4 (via Gate). Attenuation pCT assumes an energy-independent inelastic cross-section, and the impact of the energy dependence of the inelastic crosssection below 100 MeV showed a capping artifact when the residual energy was below 100 MeV behind the object. The statistical limitation has been determined analytically and it was found that the noise in attenuation pCT images is 411 times and 278 times higher than the noise in energy-loss pCT images for the same imaging dose at 200 MeV and 300 MeV, respectively. Comparison of the spatial resolution of attenuation pCT images with a conventional straight-line path binning showed that incorporating the MLP estimates during reconstruction improves the spatial resolution of attenuation pCT. Moreover, regardless of the significant noise in attenuation pCT images, the spatial resolution of attenuation pCT was better than that of conventional energy-loss pCT in some studied situations thanks to the interplay of MCS and attenuation known as the West-Sherwood effect.
引用
收藏
页码:3258 / 3278
页数:21
相关论文
共 50 条
  • [31] Study on an Improved Filtered Back-projection Image Reconstruction Algorithm Combined with Wavelet Denoising
    Ren, Zhong
    Liu, Guodong
    Huang, Zhen
    [J]. INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: INFRARED IMAGING AND APPLICATIONS, 2013, 8907
  • [32] Myocardial perfusion SPECT image reconstruction with an iteration algorithm vs filtered back-projection
    Meristoudis, G.
    Boutsali, S.
    Kokkinou-Paschou, A.
    Giougi, A.
    Giannakopoulos, V.
    Giourgouli, S.
    Roussis, C.
    Balomenos, A.
    Batsakis, C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S455 - S455
  • [33] Studies on filtered back-projection imaging reconstruction based on a modified wavelet threshold function
    Wang, Zhengzi
    Ren, Zhong
    Liu, Guodong
    [J]. OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY IV, 2016, 10020
  • [34] An investigation of spatial resolution and noise in reconstructed CT images using iterative reconstruction (IR) and filtered back-projection (FBP)
    Anam, C.
    Haryanto, F.
    Widita, R.
    Arif, I.
    Dougherty, G.
    [J]. 6TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES, 2019, 1127
  • [35] Gamma-ray momentum reconstruction from Compton electron trajectories by filtered back-projection
    Haefner, A.
    Gunter, D.
    Plimley, B.
    Pavlovsky, R.
    Vetter, K.
    [J]. APPLIED PHYSICS LETTERS, 2014, 105 (18)
  • [36] Quantitative Evaluation of 3D Reconstruction Using Filtered Back-Projection on XCAT Phantom
    Farhat, Jumana
    Alatoom, Aseel
    Dhou, Salam
    [J]. 2019 3RD INTERNATIONAL CONFERENCE ON COMMUNICATIONS, SIGNAL PROCESSING, AND THEIR APPLICATIONS (ICCSPA), 2019,
  • [37] Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection
    Korn, A.
    Fenchel, M.
    Bender, B.
    Danz, S.
    Hauser, T. K.
    Ketelsen, D.
    Flohr, T.
    Claussen, C. D.
    Heuschmid, M.
    Ernemann, U.
    Brodoefel, H.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (02) : 218 - 224
  • [38] COMPARISON OF THE CLINICAL-VALUE OF A METHOD OF ITERATIVE RECONSTRUCTION WITH THAT OF FILTERED BACK-PROJECTION IN SPECT OF THE LIVER
    REULAND, P
    MULLERSCHAUENBURG, W
    LUIG, H
    ESCHNER, W
    FEINE, U
    [J]. NUKLEARMEDIZIN, 1989, 28 (04) : 139 - 144
  • [39] UTILIZATION OF CROSS-PLANE RAYS FOR 3-DIMENSIONAL RECONSTRUCTION BY FILTERED BACK-PROJECTION
    PELC, NJ
    CHESLER, DA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) : 385 - 395
  • [40] Acceleration of Filtered Back-Projection Algorithm for 3D Cone-Beam CT Reconstruction Using Parallel Computation
    Rajruangrabin, Jartuwat
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thajchayapong, Pairash
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,