Effect of DC voltage on dielectric properties of low-voltage cable with XLPE insulation

被引:1
|
作者
Zhang, XH [1 ]
Hu, QJ [1 ]
Gao, JG [1 ]
Liu, Y [1 ]
机构
[1] Harbin Univ Sci & Technol, Inst Elect & Elect Engn, Harbin 150040, Peoples R China
关键词
D O I
10.1109/ISEIM.2005.193446
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The microstructures of a XLPE cable sample in service for one year (sample-A) and a fresh XLPE cable sample (sample-B), which were applied high electrical stress in order to initiate electrical tree, were observed by means of scan electronic microscope (SEM) and optic microscopy. It is found that the electrical trees in sample-A are longer in length and more in dimensionality than those of sample-B. Some special traces appear in SEM image of sample-A, which are thought to be additive crystallite separating from polymer under high electrical stress. Dielectric loss tangent (tan delta) of sample-A at 110(i) is higher 30% than that of sample-B. However phenomenon of insulation resistance of sample-A falling did not be observed in the test, which is different from the monitoring results of sample-A in service.
引用
收藏
页码:624 / 627
页数:4
相关论文
共 50 条
  • [21] Aging investigation of low-voltage cable insulation used in nuclear power plants
    Fabiani, Davide
    Suraci, Simone V.
    Bulzaga, Stefano
    [J]. 2018 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2018, : 516 - 519
  • [22] On the Degradation Mechanism of Low-Voltage Underground Cable with Poly(Vinyl Chloride) Insulation
    Tawancy, H. M.
    Hassan, M.
    [J]. JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2016, 25 (06) : 2288 - 2295
  • [23] Aging investigation of low-voltage cable insulation used in nuclear power plants
    Verardi, L.
    Fabiani, D.
    Montanari, G. C.
    Gedde, U. W.
    Linde, E.
    [J]. 2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 851 - 854
  • [24] Application of optical diagnosis to aged low-voltage cable insulation in nuclear plants
    Takezawa, Y
    Katagiri, J
    Shoji, H
    [J]. 2004 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2004, : 290 - 293
  • [25] Application of optical diagnosis to aged low-voltage cable insulation in nuclear plants
    Katagiri, Junichi
    Takezawa, Yoshitaka
    Shouji, Hiroshi
    [J]. IEEJ Transactions on Fundamentals and Materials, 2008, 128 (06) : 421 - 426
  • [26] Improved DC Insulation Performance of XLPE With Graftable Voltage Stabilizer
    Deng, Wei
    Ren, Yuanyuan
    Qu, Kexin
    Zhao, Hong
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2022, 29 (05) : 1857 - 1864
  • [27] On the Degradation Mechanism of Low-Voltage Underground Cable with Poly(Vinyl Chloride) Insulation
    H. M. Tawancy
    M. Hassan
    [J]. Journal of Materials Engineering and Performance, 2016, 25 : 2288 - 2295
  • [28] Ageing Condition Assessment of DC Cable XLPE Insulation by Tan 6 Measurement at 0.1 Hz Voltage
    Liu, Ying
    Su, Yu
    Wang, Linjie
    Xiao, Yang
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), VOLS 1-2, 2016, : 776 - 779
  • [29] Annealing Effects on XLPE Insulation of Retired High-Voltage Cable
    Xie, Yue
    Zhao, Yifeng
    Liu, Gang
    Huang, Jiasheng
    Li, Licheng
    [J]. IEEE ACCESS, 2019, 7 : 104344 - 104353
  • [30] Advanced technology for high and extra high voltage XLPE cable insulation
    Huotari, Pekka