Development of a biosensor for gaseous cyanide in solution

被引:17
|
作者
Lee, JI [1 ]
Karube, I [1 ]
机构
[1] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,MEGURO KU,TOKYO 153,JAPAN
来源
BIOSENSORS & BIOELECTRONICS | 1996年 / 11卷 / 11期
关键词
gas-phase biosensor; microbial electrode; P-fluorescens NCIMB 11764; cyanide; environmental monitoring;
D O I
10.1016/0956-5663(96)82337-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A gas-phase biosensor was developed using cyanide degrading bacteria, an oxygen electrode and a gas permeable PTFE membrane; Cyanide degrading bacteria, Pseudomonas fluorescens NCIMB 11764, consume oxygen upon degradation of cyanide. A change in oxygen concentration was detected using a Clark oxygen electrode. A linear relationship was observed between the current decrease and the cyanide ion concentration in the range 0.1-1 mg/l. The optimum working conditions of the sensor were pH 2 and 30 degrees C. The sensor was unaffected by heavy-metal ions and biochemical oxygen demand (glucose, glutamic acid). A good correlation was found between results obtained with the biosensor and those obtained using the Japanese Industrial Standard (JIS) method. The correlation coefficient was 0.995. When the biosensor was stored at 4 degrees C, but operated at 30 degrees C, the sensor was stable for up to 1 month. (C) 1996 Elsevier Science Limited
引用
收藏
页码:1147 / 1154
页数:8
相关论文
共 50 条
  • [31] RECOVERING BRASS CYANIDE PLATING SOLUTION
    不详
    INDUSTRIAL FINISHING, 1978, 54 (06): : 48 - 49
  • [32] CYANIDE COMPLEXES OF COPPER(I) IN SOLUTION
    KAPPENST.C
    PIERRARD, JC
    HUGEL, R
    BULLETIN DE LA SOCIETE CHIMIQUE DE FRANCE, 1970, (7B): : 50 - &
  • [33] Cyanide solution detoxification - Jar tests
    Bucknam, CH
    GLOBAL EXPLOITATION OF HEAP LEACHABLE GOLD DEPOSITS, 1997, : 191 - 204
  • [34] Novel reactor for cyanide solution treatment
    Fortin, L
    Soucy, G
    Kasireddy, VK
    Bernier, JL
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2000, 78 (04): : 643 - 649
  • [35] Bioinspired/Chemically Enhanced Biosensor for Detection of Gaseous Isopropyl Alcohol
    Walnoha, Cody
    Brothers, Michael
    Littlejohn, Taneha
    Islam, Ahmad
    Maruyarna, Benji
    Martin, Jennifer
    Grigsby, Claude
    Naik, Rajesh
    Kim, Steve
    2019 IEEE RESEARCH AND APPLICATIONS OF PHOTONICS IN DEFENSE CONFERENCE (RAPID), 2019,
  • [36] A Potentiometric Biosensor for Cyanide Detection using Immobilized Whole Cell Cyanide Dihydratase of Flavobacterium indicum MTCC 6936
    Vijay Virender Kumar
    Ashish Kumar Kumar
    Neelam Singh
    Tek Chand Verma
    Journal of Analytical Chemistry, 2018, 73 : 1014 - 1019
  • [37] Application of cyanide hydrolase from Klebsiella sp. in a biosensor system for the detection of low-level cyanide
    Karen K. W. Mak
    Alex W. C. Law
    Shinsuke Tokuda
    Hideshi Yanase
    Reinhard Renneberg
    Applied Microbiology and Biotechnology, 2005, 67 : 631 - 636
  • [38] A Potentiometric Biosensor for Cyanide Detection using Immobilized Whole Cell Cyanide Dihydratase of Flavobacterium indicum MTCC 6936
    Kumar, Virender
    Kumar, Vijay
    Singh, Ashish Kumar
    Verma, Neelam
    Bhalla, Tek Chand
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (10) : 1014 - 1019
  • [39] REACTION OF GASEOUS HYDROGEN-CYANIDE ON MANGANESE AND IRON, COBALT, NICKEL
    CAILLET, M
    BESSON, J
    NOULHIAN.A
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE C, 1972, 274 (22): : 1824 - &
  • [40] Cytochrome c biosensor for determination of trace levels of cyanide and arsenic compounds
    Fuku, Xolile
    Iftikar, Faiza
    Hess, Euodia
    Iwuoha, Emmanuel
    Baker, Priscilla
    ANALYTICA CHIMICA ACTA, 2012, 730 : 49 - 59