Noninvasive Diagnosis of Adenomyosis: A Structured Review and Meta-analysis of Diagnostic Accuracy in Imaging

被引:91
|
作者
Tellum, Tina [1 ]
Nygaard, Staale [1 ,2 ]
Lieng, Marit [1 ,3 ]
机构
[1] Oslo Univ Hosp, Dept Gynecol, PB 4950, N-0424 Oslo, Norway
[2] Univ Oslo, Dept Informat, Fac Math & Nat Sci, Oslo, Norway
[3] Univ Oslo, Inst Clin Med, Fac Med, Oslo, Norway
关键词
Diagnostic test; Magnetic resonance imaging; Ultrasonography; Uterus; Transvaginal ultrasound; TRANSVAGINAL SONOGRAPHY; ULTRASOUND; ULTRASONOGRAPHY; ELASTOGRAPHY; PREDICTION; FEATURES; DOPPLER;
D O I
10.1016/j.jmig.2019.11.001
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To conduct a systematic review and meta-analysis to evaluate imaging methods used to diagnose adenomyosis. Data Sources: A thorough search was completed through the Cochrane Central Register of Controlled Trials, EMBASE, and PubMed or MEDLINE databases from January 2000 to June 2019. Methods of Study Selection: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and the Quality Assessment of Diagnostic Accuracy Studies 2 tool, studies reporting the diagnostic accuracy of an imaging method and histopathology as a reference standard were selected and prospectively registered in the International Prospective Register of Systematic Reviews. Statistical analysis was performed using the R-package Meta-Analysis of Diagnostic Accuracy. Tabulation, Integration, and Results: Of the 1168 records identified, 10 studies were included in the meta-analysis, and these included 827 patients undergoing 2- or 3-dimensional transvaginal ultrasound (TVUS) and 317 patients undergoing magnetic resonance imaging (MRI). The risk of bias was low or unclear for all Quality Assessment of Diagnostic Accuracy Studies domains. The overall prevalence of adenomyosis was 40%. Overall MRI, 2-dimensional TVUS, 3-dimensional TVUS, and TVUS had the following aggregated diagnostic qualities (95% confidence interval): sensitivity of 78% (70%-84%), 74% (68%-79%), 84% (77%-89%), 78% (73%-82%); specificity of 88% (83%-92%), 76% (71%-79%), 84% (77%-89%), 78% (74%-81%); positive likelihood ratio of 6.8 (4.5%-10%), 3 (2.5%-3.7%), 5.2 (3.6%-7.4%), 3.5 (3%-4.2%); negative likelihood ratio of 0.25 (0.18%-0.35%), 0.34 (0.27%-0.43%), 0.19 (0.13%-0.28%), 0.28 (0.23%-0.34%); and pooled area under the operator curve of 0.77, 0.7, 0.83, 0.73, respectively. The pooled area under the operator curve for all modalities was not significantly different (all: p >= .4). Conclusion: As a result of the systemic review and meta-analysis, we identified TVUS and MRI as good and comparable noninvasive imaging methods for diagnosing adenomyosis, leading us to recommend TVUS as the first-line diagnostic imaging method and MRI as a second-line method, if TVUS is inconclusive. (C) 2019 AAGL. All rights reserved.
引用
收藏
页码:408 / +
页数:14
相关论文
共 50 条
  • [21] The accuracy of diagnostic imaging for the assessment of chronic osteomyelitis: A systematic review and meta-analysis
    Termaat, MF
    Raijmakers, PGHM
    Scholten, HJ
    Bakker, FC
    Patka, P
    Haarman, HJTM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11): : 2464 - 2471
  • [22] Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
    Ravi Aggarwal
    Viknesh Sounderajah
    Guy Martin
    Daniel S. W. Ting
    Alan Karthikesalingam
    Dominic King
    Hutan Ashrafian
    Ara Darzi
    npj Digital Medicine, 4
  • [23] Diagnostic accuracy of magnetic resonance imaging for diagnosis of spondylolysis in children and young adults: a Systematic Review and Meta-Analysis
    Dhouib, Amira
    Tabard-Fougere, Anne
    Dayer, Romain
    SWISS MEDICAL WEEKLY, 2017, 147 : 26S - 26S
  • [24] Diagnostic accuracy of imaging devices in glaucoma: A meta-analysis
    Fallon, Monica
    Valero, Oliver
    Pazos, Marta
    Anton, Alfonso
    SURVEY OF OPHTHALMOLOGY, 2017, 62 (04) : 446 - 461
  • [25] ULTRASOUND ELASTOGRAPHY FOR THE DIAGNOSIS OF ENDOMETRIOSIS AND ADENOMYOSIS: A SYSTEMATIC REVIEW WITH META-ANALYSIS
    Brunelli, Ana Claudia
    Brito, Luiz Gustavo Oliveira
    Moro, Flavia Assad Salum
    Jales, Rodrigo Menezes
    Yela, Daniela Angerame
    Benetti-Pinto, Cristina Laguna
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (03): : 699 - 709
  • [26] Diagnostic accuracy of abdominal ultrasound for diagnosis of acute appendicitis: systematic review and meta-analysis
    Le Conte, P.
    ANNALES FRANCAISES DE MEDECINE D URGENCE, 2018, 8 (03): : 207 - 208
  • [27] Tourniquet Test for Dengue Diagnosis: Systematic Review and Meta-analysis of Diagnostic Test Accuracy
    Grande, Antonio Jose
    Reid, Hamish
    Thomas, Emma
    Foster, Charlie
    Darton, Thomas C.
    PLOS NEGLECTED TROPICAL DISEASES, 2016, 10 (08):
  • [28] Diagnostic accuracy of ultrasound in the diagnosis of Placenta accreta spectrum: systematic review and meta-analysis
    Ahmed M. Maged
    Akmal El-Mazny
    Nada Kamal
    Safaa I. Mahmoud
    Mona Fouad
    Noura El-Nassery
    Amal Kotb
    Wael S. Ragab
    Asmaa I. Ogila
    Ahmed A. Metwally
    Yossra Lasheen
    Radwa M. Fahmy
    Maha Katta
    Eman K. Shaeer
    Noha Salah
    BMC Pregnancy and Childbirth, 23
  • [29] Diagnostic accuracy of multiparametric ultrasound in the diagnosis of prostate cancer: systematic review and meta-analysis
    Tang, Yun
    Li, Xingsheng
    Jiang, Qing
    Zhai, Lingyun
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [30] Diagnostic Accuracy of Abdominal Ultrasound for Diagnosis of Acute Appendicitis: Systematic Review and Meta-analysis
    Vanja Giljaca
    Tin Nadarevic
    Goran Poropat
    Vesna Stefanac Nadarevic
    Davor Stimac
    World Journal of Surgery, 2017, 41 : 693 - 700