Tourniquet Test for Dengue Diagnosis: Systematic Review and Meta-analysis of Diagnostic Test Accuracy

被引:11
|
作者
Grande, Antonio Jose [1 ,2 ]
Reid, Hamish [2 ]
Thomas, Emma [2 ]
Foster, Charlie [2 ,3 ]
Darton, Thomas C. [4 ,5 ]
机构
[1] Univ Extremo Catarinense, Criciuma, SC, Brazil
[2] Univ Oxford, Nuffield Dept Populat Hlth, Oxford, England
[3] Univ Oxford, Nuffield Dept Populat Hlth, British Heart Fdn, Ctr Populat Approaches Noncommunicable Dis Preven, Oxford, England
[4] Univ Sheffield, Dept Infect Immun & Cardiovasc Dis, Sheffield, S Yorkshire, England
[5] Univ Oxford, Clin Res Unit, Hosp Trop Dis, Ho Chi Minh City, Vietnam
来源
PLOS NEGLECTED TROPICAL DISEASES | 2016年 / 10卷 / 08期
关键词
ACUTE FEBRILE SYNDROME; HEMORRHAGIC-FEVER; CASE CLASSIFICATION; VIRUS-INFECTION; CHILDREN; PROFILE; THROMBOCYTOPENIA; PREDICTORS; INDICATORS; OUTBREAK;
D O I
10.1371/journal.pntd.0004888
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background Dengue fever is a ubiquitous arboviral infection in tropical and sub-tropical regions, whose incidence has increased over recent decades. In the absence of a rapid point of care test, the clinical diagnosis of dengue is complex. The World Health Organisation has outlined diagnostic criteria for making the diagnosis of dengue infection, which includes the use of the tourniquet test (TT). Purpose To assess the quality of the evidence supporting the use of the TT and perform a diagnostic accuracy meta-analysis comparing the TT to antibody response measured by ELISA. Data Sources A comprehensive literature search was conducted in the following databases to April, 2016: MEDLINE (PubMed), EMBASE, Cochrane Central Register of Controlled Trials, BIOSIS, Web of Science, SCOPUS. Study Selection Studies comparing the diagnostic accuracy of the tourniquet test with ELISA for the diagnosis of dengue were included. Data Extraction Two independent authors extracted data using a standardized form. Data Synthesis A total of 16 studies with 28,739 participants were included in the meta-analysis. Pooled sensitivity for dengue diagnosis by TT was 58% (95% Confidence Interval (CI), 43%-71%) and the specificity was 71% (95% CI, 60%-80%). In the subgroup analysis sensitivity for non-severe dengue diagnosis was 55% (95% CI, 52%-59%) and the specificity was 63% (95% CI, 60%-66%), whilst sensitivity for dengue hemorrhagic fever diagnosis was 62% (95% CI, 53%-71%) and the specificity was 60% (95% CI, 48%-70%). Receiver-operator characteristics demonstrated a test accuracy (AUC) of 0.70 (95% CI, 0.66-0.74). Conclusion The tourniquet test is widely used in resource poor settings despite currently available evidence demonstrating only a marginal benefit in making a diagnosis of dengue infection alone. Registration The protocol for this systematic review was registered at PROSPERO: CRD42015020323.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Diagnostic test accuracy of ultrasound for sarcopenia diagnosis: A systematic review and meta-analysis
    Fu, Hongbo
    Wang, Lei
    Zhang, Wenyi
    Lu, Jing
    Yang, Ming
    [J]. JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2023, 14 : 57 - 70
  • [2] A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy for the Diagnosis of Cardiac Sarcoidosis
    Abialmouna, Omar
    Kalot, Mohamad
    Hamade, Mohamad
    Bahuva, Ronak
    Hasmi, Ariba
    Ahmed, Aamir
    Brumberger, Zachary
    Troy, Jordan
    Choaib, Ali
    Bharucha, Ronak
    Moyer, Ross
    Provost, Karin
    Page, Brian
    Sharma, Umesh
    [J]. ARTHRITIS & RHEUMATOLOGY, 2022, 74 : 2436 - 2438
  • [3] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    [J]. INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [4] The clock drawing test: A systematic review and meta-analysis of diagnostic accuracy
    Park, JinKyung
    Jeong, EunHye
    Seomun, GyeongAe
    [J]. JOURNAL OF ADVANCED NURSING, 2018, 74 (12) : 2742 - 2754
  • [5] Molecular Tools for Diagnosis of Visceral Leishmaniasis: Systematic Review and Meta-Analysis of Diagnostic Test Accuracy
    de Ruiter, C. M.
    van der Veer, C.
    Leeflang, M. M. G.
    Deborggraeve, S.
    Lucas, C.
    Adams, E. R.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (09) : 3147 - 3155
  • [6] Diagnostic accuracy of xpert test in tuberculosis detection: A systematic review and meta-analysis
    Kaur, Ravdeep
    Kachroo, Kavita
    Sharma, Jitendar Kumar
    Vatturi, Satyanarayana Murthy
    Dang, Amit
    [J]. JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2016, 8 (01) : 32 - 40
  • [7] Chest ultrasound for the diagnosis of paediatric pulmonary diseases: a systematic review and meta-analysis of diagnostic test accuracy
    Heuvelings, Charlotte C.
    Belard, Sabine
    Familusi, Mary A.
    Spijker, Rene
    Grobusch, Martin P.
    Zar, Heather J.
    [J]. BRITISH MEDICAL BULLETIN, 2019, 129 (01) : 35 - 51
  • [8] Diagnostic Test Accuracy of Provocative Maneuvers for the Diagnosis of Carpal Tunnel Syndrome: A Systematic Review and Meta-Analysis
    Dabbagh, Armaghan
    MacDermid, Joy C.
    Yong, Joshua
    Packham, Tara L.
    Grewal, Ruby
    Boutsikari, Eleni C.
    [J]. PHYSICAL THERAPY, 2023, 103 (06):
  • [9] Serological assays for the diagnosis of Strongyloides stercoralis infection: a systematic review and meta-analysis of diagnostic test accuracy
    Kalantari, Narges
    Chehrazi, Mohammad
    Ghaffari, Salman
    Gorgani-Firouzjaee, Tahmineh
    [J]. TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2020, 114 (06) : 459 - 469
  • [10] Accuracy of breath test for diabetes mellitus diagnosis: a systematic review and meta-analysis
    Wang, Wenting
    Zhou, Wenzhao
    Wang, Sheng
    Huang, Jinyu
    Le, Yanna
    Nie, Shijiao
    Wang, Weijue
    Guo, Qing
    [J]. BMJ OPEN DIABETES RESEARCH & CARE, 2021, 9 (01)