Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

被引:11
|
作者
de Boer, Johan [1 ]
Wolf, Anne Lisa [1 ]
Szeto, Yenny Z. [1 ]
van Herk, Marcel [1 ]
Sonke, Jan-Jakob [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
关键词
EXTERNAL-BEAM RADIOTHERAPY; ADAPTIVE RADIATION-THERAPY; IMAGE-GUIDED RADIOTHERAPY; CONFORMAL RADIOTHERAPY; SEMINAL-VESICLES; ORGAN MOTION; CANCER; PRECISION; VERIFICATION; PROBABILITY;
D O I
10.1016/j.ijrobp.2014.11.020
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15 degrees and -15 degrees were corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D-min) to the prostate, bladder surface receiving >= 78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by gamma-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D-min) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas Dmin remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15 degrees. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1009 / 1016
页数:8
相关论文
共 50 条
  • [41] Cardiac Toxicity in Intensity Modulated Radiation Therapy, Dynamic Conformal Arc Therapy, and Volumetric Modulated Arc Therapy of Lung Cancers
    Ming, X.
    Feng, Y.
    Zhang, Y.
    Zhou, L.
    Deng, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S666 - S667
  • [42] Pelvic Volumetric Modulated Arc Therapy (VMAT) for Prostate for Locally Advanced Prostate Cancer
    Ferrer, F.
    Ballon, K.
    Boladeras, A.
    De Blas, R.
    Najjari, D.
    Ventura, M.
    Bavestrello, P.
    Rojas, F.
    Bejar, S.
    Zardoya, E.
    Martinez, E.
    Comas, S.
    Gutierrez, C.
    Pera, J.
    Picon, C.
    Guedea, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E249 - E249
  • [43] Assessment of Robustly Optimized Intensity Modulated Proton Therapy and Volumetric Modulated Arc Therapy for Prostate Cancer
    Brovold, N.
    King, A.
    Xu, Y.
    Diwanji, T.
    Pollack, A.
    Dogan, N.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E625 - E625
  • [44] Dosimetric effects of weight loss or gain during volumetric modulated arc therapy and intensity-modulated radiation therapy for prostate cancer
    Pair, Matthew L.
    Du, Weiliang
    Rojas, Hector D.
    Kanke, James E.
    McGuire, Sean E.
    Lee, Andrew K.
    Kuban, Deborah A.
    Kudchadker, Rajat J.
    [J]. MEDICAL DOSIMETRY, 2013, 38 (03) : 251 - 254
  • [45] Paraspinal volumetric modulated arc therapy
    Bedford, J. L.
    Convery, H. M.
    Hansen, V. N.
    Saran, F. H.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1016): : 1128 - 1133
  • [46] Assessing the Dosimetric Impact of Real-Time Prostate Motion During Volumetric Modulated Arc Therapy
    Diego Azcona, Juan
    Xing, Lei
    Chen, Xin
    Bush, Karl
    Li, Ruijiang
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (05): : 1167 - 1174
  • [47] Radiotherapy for maxillary sinus carcinoma: dosimetric comparison of volumetric modulated arc therapy with 0° and 90° collimator intensity modulated radiation therapy
    Sang, Yong
    Shan, Guoping
    Shao, Kainan
    Hu, Fujun
    Chen, Jing
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (1-2) : 53 - 58
  • [48] Single Arc Volumetric Modulated Arc Therapy (VMAT) for the Treatment of Prostate and Pelvic Lymph Nodes
    Wai, P.
    Sardo, A.
    Bedford, J. L.
    Warrington, A. P.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (03) : 256 - 256
  • [49] Cardiac Toxicity in Dynamic Conformal Arc Therapy, Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy of Lung Cancers
    Ming, X.
    Feng, Y.
    Zhang, Y.
    Zhou, L.
    Deng, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 236 - +
  • [50] Influence of Gantry Angle, Multi-Leaf Collimator (MLC), and Jaw Position Errors to Dose Distribution in Volumetric Modulated Arc Therapy (VMAT)
    Haga, A.
    Nakagawa, K.
    Shiraishi, K.
    Itoh, S.
    Saegusa, S.
    Imae, T.
    Sasaki, K.
    Kida, S.
    Terahara, A.
    Yoda, K.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)