Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

被引:11
|
作者
de Boer, Johan [1 ]
Wolf, Anne Lisa [1 ]
Szeto, Yenny Z. [1 ]
van Herk, Marcel [1 ]
Sonke, Jan-Jakob [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
关键词
EXTERNAL-BEAM RADIOTHERAPY; ADAPTIVE RADIATION-THERAPY; IMAGE-GUIDED RADIOTHERAPY; CONFORMAL RADIOTHERAPY; SEMINAL-VESICLES; ORGAN MOTION; CANCER; PRECISION; VERIFICATION; PROBABILITY;
D O I
10.1016/j.ijrobp.2014.11.020
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15 degrees and -15 degrees were corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D-min) to the prostate, bladder surface receiving >= 78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by gamma-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D-min) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas Dmin remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15 degrees. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1009 / 1016
页数:8
相关论文
共 50 条
  • [1] Dosimetric Dependence On the Collimator Angle in Prostate Volumetric Modulated Arc Therapy
    Khan, M.
    Rehman, J.
    Khan, M.
    Chow, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 366 - 367
  • [2] Collimator Angle Optimization in Volumetric Modulated Arc Therapy
    Andersen, A.
    Johnson, C.
    Bartlett, G.
    Das, I.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3627 - 3627
  • [3] Volumetric modulated arc therapy with dynamic collimator rotation for improved multileaf collimator tracking of the prostate
    Murtaza, Ghulam
    Toftegaard, Jakob
    Khan, Ehsan Ullah
    Poulsen, Per Rugaard
    [J]. RADIOTHERAPY AND ONCOLOGY, 2017, 122 (01) : 109 - 115
  • [4] Dynamic Collimator Rotation for Volumetric Modulated Arc Therapy
    Fix, M. K.
    Frei, D.
    Volken, W.
    Terribilini, D.
    Manser, P.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3412 - 3412
  • [5] The importance of collimator angle error in volumetric-modulated arc therapy
    Puchades-Puchades, Vicente
    Serna-Berna, Alfredo
    Mata-Colodro, Fernando
    Ramos-Amores, David
    Alcaraz-Banos, Miguel
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2015, 14 (03) : 323 - 330
  • [6] Impact of Collimator Angle on Deliverability of Volumetric Modulated Arc Therapy (VMAT)
    Hong, D.
    Bundalevski, I.
    Wong, K.
    Mokhtar, B. E.
    Ashamalla, H.
    Parameritis, J.
    Kyriacou, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E632 - E632
  • [7] Effect of the Collimator Angle on Dosimetric Verification of Volumetric Modulated Arc Therapy
    Kim, Yong Ho
    Park, Ha Ryung
    Kim, Won Taek
    Kim, Dong Won
    Ki, Yongkan
    Lee, Juhye
    Bae, Jinsuk
    Park, Dahl
    Jeon, Hosang
    Nam, Ji Ho
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 243 - 247
  • [8] Effect of the collimator angle on dosimetric verification of volumetric modulated arc therapy
    Yong Ho Kim
    Ha Ryung Park
    Won Taek Kim
    Dong Won Kim
    Yongkan Ki
    Juhye Lee
    Jinsuk Bae
    Dahl Park
    Hosang Jeon
    Ji Ho Nam
    [J]. Journal of the Korean Physical Society, 2015, 67 : 243 - 247
  • [9] Volumetric modulated arc therapy optimization including dynamic collimator rotation
    Fix, M. K.
    Frei, D.
    Volken, W.
    Terribilini, D.
    Manser, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S763 - S763
  • [10] Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy
    Nakaguchi Y.
    Ono T.
    Onizuka R.
    Maruyama M.
    Shimohigashi Y.
    Kai Y.
    [J]. Radiological Physics and Technology, 2016, 9 (1) : 121 - 126