Effect of the collimator angle on dosimetric verification of volumetric modulated arc therapy

被引:0
|
作者
Yong Ho Kim
Ha Ryung Park
Won Taek Kim
Dong Won Kim
Yongkan Ki
Juhye Lee
Jinsuk Bae
Dahl Park
Hosang Jeon
Ji Ho Nam
机构
[1] Pusan National University Hospital,Department of Radiation Oncology, Pusan National University School of Medicine, Biomedical Research Institute
[2] Pusan National University Yangsan Hospital,Department of Radiation Oncology
来源
关键词
VMAT; Patient specific QA; Collimator angle;
D O I
暂无
中图分类号
学科分类号
摘要
The collimator is usually rotated when planning volumetric modulated arc therapy (VMAT) due to the leakage of radiation between the multi-leaf collimator (MLC) leaves. We studied the effect of the collimator angle on the results of dosimetric verification of VMAT plans for head and neck patients. We studied VMAT plans for 10 head and neck patients. We made two sets of VMAT plans for each patient. Each set was composed of 10 plans with collimator angles of 0, 5, 10, 15, 20, 25, 30, 35, 40, 45 degrees. Plans in the first set were optimized individually, and plans in the second set shared the 30-degree collimator-angle optimization. The two sets of plans were verified by using the 2-dimensional ion chamber array MatriXX (IBA Dosimetry, Germany). The comparisons between the calculation and the measurements were made by using a γ-index analysis. The γ-index (2%/2 mm) and (3%/3 mm) passing rates had negative correlations with the collimator angle. The maximum difference between γ-index (3%/3 mm) passing rates of different collimator angles for each patient ranged from 1.46% to 5.60% with an average of 3.67%. There were significant differences (maximum 5.6%) in the passing rates for different collimator angles. The results suggested that the accuracy of the delivered dose depended on the collimator angle. These findings are informative when choosing a collimator angle for VMAT plans.
引用
收藏
页码:243 / 247
页数:4
相关论文
共 50 条
  • [1] Effect of the Collimator Angle on Dosimetric Verification of Volumetric Modulated Arc Therapy
    Kim, Yong Ho
    Park, Ha Ryung
    Kim, Won Taek
    Kim, Dong Won
    Ki, Yongkan
    Lee, Juhye
    Bae, Jinsuk
    Park, Dahl
    Jeon, Hosang
    Nam, Ji Ho
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (01) : 243 - 247
  • [2] Dosimetric Dependence On the Collimator Angle in Prostate Volumetric Modulated Arc Therapy
    Khan, M.
    Rehman, J.
    Khan, M.
    Chow, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 366 - 367
  • [3] Collimator Angle Optimization in Volumetric Modulated Arc Therapy
    Andersen, A.
    Johnson, C.
    Bartlett, G.
    Das, I.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3627 - 3627
  • [4] DOSIMETRIC VERIFICATION OF RAPIDARC™ VOLUMETRIC MODULATED ARC THERAPY
    Medin, J.
    Kjaer-Kristoffersen, F.
    Ceberg, S.
    Back, S.
    Gustavsson, H.
    Archambault, Y.
    Bocanek, J.
    Cozzi, L.
    Eberhard, V.
    Gomola, I.
    Wiberg, I.
    Korreman, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S47 - S48
  • [5] Dosimetric Verification for Volumetric Modulated Arc Therapy (VMAT) with Gating
    Qian, J.
    Xing, L.
    Luxton, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [6] The importance of collimator angle error in volumetric-modulated arc therapy
    Puchades-Puchades, Vicente
    Serna-Berna, Alfredo
    Mata-Colodro, Fernando
    Ramos-Amores, David
    Alcaraz-Banos, Miguel
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2015, 14 (03) : 323 - 330
  • [7] Impact of Collimator Angle on Deliverability of Volumetric Modulated Arc Therapy (VMAT)
    Hong, D.
    Bundalevski, I.
    Wong, K.
    Mokhtar, B. E.
    Ashamalla, H.
    Parameritis, J.
    Kyriacou, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E632 - E632
  • [8] Clinical Implementation and dosimetric Verification of Volumetric Modulated Arc Therapy (VMAT)
    Wolff, D.
    Barrois, V
    Vogelgesang, L.
    Bosold, S.
    Tsogtbaatar, L.
    Sparenberg, J.
    Engenhart-Cabillic, R.
    Zink, K.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 157 - 157
  • [9] Choreographing Couch and Collimator in Volumetric Modulated Arc Therapy
    Yang, Y.
    Zhang, P.
    Happersett, L.
    Xiong, J.
    Yang, J.
    Chan, M.
    Mageras, G.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3369 - +
  • [10] Dynamic Collimator Rotation for Volumetric Modulated Arc Therapy
    Fix, M. K.
    Frei, D.
    Volken, W.
    Terribilini, D.
    Manser, P.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3412 - 3412