Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites

被引:32
|
作者
Miletic, Vesna [1 ]
Peric, Dejan [2 ]
Milosevic, Milos [3 ]
Manojlovic, Dragica [1 ,5 ]
Mitrovic, Nenad [4 ]
机构
[1] Univ Belgrade, Sch Dent Med, DentalNet Res Grp, Rankeova 4, Belgrade 11000, Serbia
[2] Univ Pristina, Sch Med, Dent Clin, Anri Dinana St, Kosovska Mitrovica 38220, Serbia
[3] Univ Belgrade, Fac Mech Engn, Innovat Ctr, Kraljice Marije 16, Belgrade 11120, Serbia
[4] Univ Belgrade, Fac Mech Engn, Kraljice Marije 16, Belgrade 11120, Serbia
[5] Univ Belgrade, Vinca Inst Nucl Sci, POB 522, Belgrade 11001, Serbia
关键词
Bulk-fill; Low-shrinkage; Giomer; Composites; Shrinkage; Microleakage; POLYMERIZATION SHRINKAGE; MECHANICAL-PROPERTIES; RESIN-COMPOSITES; STRESS; DEPTH; CURE; RESTORATIONS; MICROLEAKAGE; CONTRACTION; ADAPTATION;
D O I
10.1016/j.dental.2016.09.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. To compare strain and displacement of sculptable bulk-fill, low-shrinkage and conventional composites as well as dye penetration along the dentin-restoration interface. Methods. Modified Class II cavities (N= 5/group) were filled with sculptable bulk-fill (Filtek Bulk Fill Posterior, 3M ESPE; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; fiber-reinforced EverX Posterior, GC; giomer Beautifil Bulk, Schofu), low-shrinkage (Kalore, GC), nanohybrid (Tetric EvoCeram, Ivoclar Vivadent) or microhybrid (Filtek Z250, 3M ESPE) composites. Strain and displacement were determined using the 3D digital image correlation method based on two cameras with 1 mu m displacement sensitivity and 1600 x 1200 pixel resolution (Aramis, GOM). Microleakage along dentin axial and gingival cavity walls was measured under a stereomicroscope using a different set of teeth (N = 8/group). Data were analyzed using analyses of variance with Tukey's post-test, Pearson correlation and paired t-test (alpha = 0.05). Results. Strain of TEC Bulk, Filtek Bulk, Beautifil Bulk and Kalore was in the range of 1-1.5%. EverX and control composites showed 1.5-2% strain. Axial displacements were between 5 mu m and 30 mu m The least strain was identified at 2 mm below the occlusal surface in 4-mm but not in 2-mm layered composites. Greater microleakage occurred along the gingival than axial wall (p < 0.05). No correlation was found between strain/displacements and microleakage axially (r(2) = 0.082, p = 0.821; r(2) =-0.2, p = 0.605, respectively) or gingivally (r(2) =-0.126, p = 0.729, r(2) =-0.278, p = 0.469, respectively). Significance. Strain i.e. volumetric shrinkage of sculptable bulk-fill and low-shrinkage composites was comparable to control composites but strain distribution across restoration depth differed. Marginal integrity was more compromised along the gingival than axial dentin wall. (C) 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1441 / 1451
页数:11
相关论文
共 50 条
  • [1] Curing characteristics of flowable and sculptable bulk-fill composites
    Miletic, Vesna
    Pongprueksa, Pong
    De Munck, Jan
    Brooks, Neil R.
    Van Meerbeek, Bart
    [J]. CLINICAL ORAL INVESTIGATIONS, 2017, 21 (04) : 1201 - 1212
  • [2] Curing characteristics of flowable and sculptable bulk-fill composites
    Vesna Miletic
    Pong Pongprueksa
    Jan De Munck
    Neil R. Brooks
    Bart Van Meerbeek
    [J]. Clinical Oral Investigations, 2017, 21 : 1201 - 1212
  • [3] Polymer characteristics and mechanical properties of bulk-fill, giomer, fiber-reinforced, and low-shrinkage composites
    Peric, Dejan
    Ruzic, Jovana
    Levic, Steva
    Stasic, Jovana N.
    [J]. SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2022, 150 (7-8) : 414 - 420
  • [4] Shrinkage vectors in flowable bulk-fill and conventional composites: bulk versus incremental application
    Kaisarly, Dalia
    El Gezawi, Moataz
    Kessler, Andreas
    Roesch, Peter
    Kunzelmann, Karl-Heinz
    [J]. CLINICAL ORAL INVESTIGATIONS, 2021, 25 (03) : 1127 - 1139
  • [5] Degree of conversion and polymerization shrinkage of low shrinkage bulk-fill resin composites
    Salem, Haidy N.
    Hefnawy, Sherif M.
    Nagi, Shaymaa M.
    [J]. CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (03) : 465 - 470
  • [6] Shrinkage vectors in flowable bulk-fill and conventional composites: bulk versus incremental application
    Dalia Kaisarly
    Moataz El Gezawi
    Andreas Keßler
    Peter Rösch
    Karl-Heinz Kunzelmann
    [J]. Clinical Oral Investigations, 2021, 25 : 1127 - 1139
  • [7] Marginal integrity and physicomechanical properties of a thermoviscous and regular bulk-fill resin composites
    Soares, Barbara Monteiro
    Barbosa, Marianna Pires
    de Almeida, Rayane Velloso
    Jardim, Renata Nunes
    da Silva, Eduardo Moreira
    [J]. CLINICAL ORAL INVESTIGATIONS, 2024, 28 (09)
  • [8] The Effect of Gravity on Marginal Integrity of Different Flowable Bulk-Fill Resin Composites
    Baltacioglu, Ismail Hakki
    Demirel, Gulbike
    Kolsuz, Mehmet Eray
    Orhan, Kaan
    [J]. MEDICINA-LITHUANIA, 2024, 60 (03):
  • [9] MARGINAL SEALING ABILITY OF BULK-FILL VS CONVENTIONAL COMPOSITES; A SYSTEMATIC REVIEW
    Alajmi, Aljazi Mohammed
    AlAmoudi, Raghad Saeed
    Juma, Reem Abdullah Ibn
    Alotaibi, Nouf Awadh
    Alharbi, Khalid Naif
    [J]. ANNALS OF DENTAL SPECIALTY, 2023, 11 (04): : 62 - 69
  • [10] Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites
    Fronza, Bruna Marin
    Rueggeberg, Frederick Allen
    Braga, Roberto Ruggiero
    Mogilevych, Borys
    Silva Soares, Luis Eduardo
    Martin, Airton Abrahao
    Ambrosano, Glaucia
    Giannini, Marcelo
    [J]. DENTAL MATERIALS, 2015, 31 (12) : 1542 - 1551