Common-path optical coherence tomography using a microelectromechanical-system-based endoscopic probe

被引:8
|
作者
Wang, Donglin [1 ,3 ]
Duan, Can [2 ]
Zhang, Xiaoyang [2 ]
Yun, Zhao [3 ]
Pozzi, Antonio [4 ]
Xie, Huikai [2 ,3 ]
机构
[1] Zhengzhou Univ Light Ind, Sch Phys & Elect Engn, Zhengzhou 450002, Peoples R China
[2] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
[3] WiO Technol Ltd Co, Wuxi 214028, Peoples R China
[4] Univ Zurich, Clin Small Anim Surg, CH-8006 Zurich, Switzerland
基金
美国国家科学基金会;
关键词
NUMERICAL DISPERSION COMPENSATION; HIGH-SPEED; ULTRAHIGH-RESOLUTION; DOPPLER TOMOGRAPHY; MIRROR; VELOCITY; INTERFEROMETER; SENSITIVITY; SCANNER; COLON;
D O I
10.1364/AO.55.006930
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper presents a common-path (CP) swept-source optical coherence tomography (SSOCT) system based on a special endoscopic probe design with an in-line internal reflection as the reference and a two-axis electrothermal microelectromechanical system mirror for image scanning. The rear surface of a gradient reflective index (GRIN) lens inside the probe is set as the reference reflection plane. The length of the GRIN lens is optimized to eliminate the artifacts in SSOCT images successfully. Doppler OCT is also demonstrated based on the CP endoscopic probe. The diameter of the probe is only 2.5 mm, so it can be easily inserted into the biopsy channel of traditional endoscopes to access human internal organs for in vivo diagnoses. (C) 2016 Optical Society of America
引用
收藏
页码:6930 / 6935
页数:6
相关论文
共 50 条
  • [41] Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
    Utkarsh Sharma
    Jin U.Kang
    Chinese Optics Letters, 2008, 6 (12) : 910 - 912
  • [42] Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
    Sharma, Utkarsh
    Kang, Jin U.
    CHINESE OPTICS LETTERS, 2008, 6 (12) : 910 - 912
  • [43] Chip based common-path optical coherence tomography system with an on-chip microlens and multi-reference suppression algorithm
    Chang, Lantian
    Weiss, Nicolas
    van Leeuwen, Ton G.
    Pollnau, Markus
    de Ridder, Rene M.
    Worhoff, Kerstin
    Subramaniam, Vinod
    Kanger, Johannes S.
    OPTICS EXPRESS, 2016, 24 (12): : 12635 - 12650
  • [44] Distal-scanning common path probe for optical coherence tomography
    Chen, Zhengyu
    He, Bin
    Yin, Zichen
    Hu, Zhangwei
    Shi, Yejiong
    Wang, Chengming
    Zhang, Xiao
    Zhang, Ning
    Jing, Linkai
    Wang, Guihuai
    Xue, Ping
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2024, 17 (03)
  • [45] Polymer microlens fiber probe for Common Path Optical Coherence Tomography
    Xiao, Hai
    Zhang, Yinan
    Pieonkowski, Edward
    Wei, Tao
    Lan, Xinwei
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVI, 2012, 8213
  • [46] Common path endoscopic probes for optical coherence tomography (Conference Presentation)
    Singh, Kanwarpal
    Gardecki, Joseph A.
    Tearney, Guillermo J.
    ENDOSCOPIC MICROSCOPY XII, 2017, 10040
  • [47] Common-path all-fiber optical coherence tomography probe based on high-index elliptical epoxy-lensed fiber
    Lee, Soohyun
    Lee, Changho
    Verkade, Ruben
    Cheon, Gyeong Woo
    Kang, Jin U.
    OPTICAL ENGINEERING, 2019, 58 (02)
  • [48] Stable fiber-based polarization-sensitive optical coherence tomography using polarization maintaining common-path interferometer
    Tang, Peijun
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (11)
  • [49] Common-path intrinsically achromatic optical diffraction tomography
    Zdankowski, Piotr
    Winnik, Julianna
    Patorski, Krzysztof
    Goclowski, Pawel
    Ziemczonok, Michal
    Jozwik, Michal
    Kujawinska, Malgorzata
    Trusiak, Maciej
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (07) : 4219 - 4234
  • [50] Common-path diffraction optical tomography with a low-coherence illumination for reducing speckle noise
    Shin, Seungwoo
    Kim, Youngchan
    Lee, KyeoReh
    Kim, Kyoohyun
    Kim, Young-Jin
    Park, HyunJoo
    Park, YongKeun
    QUANTITATIVE PHASE IMAGING, 2015, 9336