Diagnostic performance of multidetector CT angiography for assessment of coronary artery disease: Meta-analysis

被引:318
|
作者
Vanhoenacker, Piet K.
Heijenbrok-Kal, Majanka H.
Van Heste, Ruben
Decramer, Isabel
Van Hoe, Lieven R.
William, Wijns
Hunink, M. G. Myriam
机构
[1] OLV Ziekenhuis Aalst, Dept Radiol & Med Imaging, B-9300 Aalst, Belgium
[2] OLV Ziekenhuis Aalst, Ctr Cardiovasc, B-9300 Aalst, Belgium
[3] Erasmus MC Univ Med Ctr Rotterdam, Dept Epidemiol & Biostat, Program Assessment Radiol Technol, Rotterdam, Netherlands
[4] Erasmus MC Univ Med Ctr Rotterdam, Dept Radiol, Rotterdam, Netherlands
关键词
D O I
10.1148/radiol.2442061218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To review the literature on the diagnostic performance of multidetector computed tomographic (CT) angiography for assessment of symptomatic coronary artery disease, with conventional coronary angiography as the reference standard. Materials and Methods: A PubMed and manual search of the literature published between January 1998 and May 2006 on use of multidetector CT angiography compared with coronary angiography in patients with symptomatic coronary artery disease was performed. Summary estimates of diagnostic odds ratio, sensitivity, and specificity were calculated. Random-effects models were used to compare the diagnostic performance of four-, 16-, and 64-detector CT angiographic units, and the proportion of nonassessable coronary arterial segments was evaluated. Results: Fifty-four studies were included in the meta-analysis: 22 studies with four-detector CT angiography, 26 with 16-detector CT angiography, and six with 64-detector CT angiography. The pooled sensitivity and specificity for detecting a greater than 50% stenosis per segment were 0.93 (95% confidence interval [CI]: 0.88, 0.97) and 0.96 (95% CI: 0.96, 0.97) for 64-detector CT angiography, 0.83 ( 95% CT: 0.76, 0.90) and 0.96 ( 95% CI: 0.95, 0.97) for 16-detector CT angiography, and 0.84 ( 95% CI: 0.81, 0.88) and 0.93 (95% CI: 0.91, 0.95) for four-detector CT angiography, respectively. Results of regression analysis indicated that the diagnostic performance significantly improved with the newer generations of multidetector CT scanners (64- and 16-detector vs four-detector units), adjusted for exclusion of nonassessable segments, and contrast agent concentration used ( P <.05). Simultaneously, the nonassessable proportion of segments significantly decreased with the newer generations of multidetector CT scanners, adjusted for heart rate, prevalence of significant disease, and mean age. Conclusion: With the newer generations of multidetector CT scanners, the diagnostic performance for the assessment of coronary artery disease has significantly improved, and the proportion of nonassessable segments has decreased.
引用
收藏
页码:419 / 428
页数:10
相关论文
共 50 条
  • [21] Diagnostic performance of positron emission tomography in the detection of coronary artery disease: A meta-analysis
    Nandalur, Kiran R.
    Dwamena, Ben A.
    Choudhri, Asim F.
    Nandalur, Sirisha R.
    Reddy, Priya
    Carlos, Ruth C.
    ACADEMIC RADIOLOGY, 2008, 15 (04) : 444 - 451
  • [22] CT Coronary Angiography as the Diagnostic investigation for Significant Coronary Artery Disease
    Lim, Michael Cl
    De larrazabal, Catherine
    Lim, Ing Haan
    Devaraj, Levinia M.
    CIRCULATION, 2010, 122 (02) : E203 - E203
  • [23] Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysis
    Di Leo, Giovanni
    Fisci, Erica
    Secchi, Francesco
    Ali, Marco
    Ambrogi, Federico
    Sconfienza, Luca Maria
    Sardanelli, Francesco
    EUROPEAN RADIOLOGY, 2016, 26 (10) : 3706 - 3718
  • [24] Diagnostic accuracy of magnetic resonance angiography for detection of coronary artery disease: a systematic review and meta-analysis
    Giovanni Di Leo
    Erica Fisci
    Francesco Secchi
    Marco Alì
    Federico Ambrogi
    Luca Maria Sconfienza
    Francesco Sardanelli
    European Radiology, 2016, 26 : 3706 - 3718
  • [25] Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography
    Kang, Koung Mi
    Choi, Sang Il
    Chun, Eun Ju
    Kim, Jeong A.
    Youn, Tae-Jin
    Choi, Dong Ju
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) : 27 - 33
  • [26] Diagnostic performance of 16- and 64-section spiral CT for coronary artery bypass graft assessment: Meta-analysis
    Hamon, Michele
    Lepage, Olivier
    Malagutti, Patrizia
    Riddell, John W.
    Morello, Remy
    Agostini, Denis
    Hamon, Martial
    RADIOLOGY, 2008, 247 (03) : 679 - 686
  • [27] Diagnostic Strategies for the Assessment of Suspected Stable Coronary Artery Disease A Systematic Review and Meta-analysis
    Zito, Andrea
    Galli, Mattia
    Biondi-Zoccai, Giuseppe
    Abbate, Antonio
    Douglas, Pamela S.
    Princi, Giuseppe
    D'Amario, Domenico
    Aurigemma, Cristina
    Romagnoli, Enrico
    Trani, Carlo
    Burzotta, Francesco
    ANNALS OF INTERNAL MEDICINE, 2023, 176 (06) : 817 - +
  • [28] Diagnostic performance of noninvasive fractional flow reserve derived from coronary computed tomography angiography in coronary artery disease: A systematic review and meta-analysis
    Deng, Song-Bai
    Jing, Xiao-Dong
    Wang, Jing
    Huang, Chuan
    Xia, Shuang
    Du, Jian-Lin
    Liu, Ya-Jie
    She, Qiang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 184 : 703 - 709
  • [29] Diagnostic performance of prone-only myocardial perfusion imaging versus coronary angiography in the detection of coronary artery disease: A systematic review and meta-analysis
    Seyed Ali Mirshahvalad
    Mohammadreza Chavoshi
    Sepideh Hekmat
    Journal of Nuclear Cardiology, 2022, 29 : 1339 - 1351
  • [30] Diagnostic performance of prone-only myocardial perfusion imaging versus coronary angiography in the detection of coronary artery disease: A systematic review and meta-analysis
    Mirshahvalad, Seyed Ali
    Chavoshi, Mohammadreza
    Hekmat, Sepideh
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (03) : 1339 - 1351