Diagnostic performance of positron emission tomography in the detection of coronary artery disease: A meta-analysis

被引:74
|
作者
Nandalur, Kiran R. [1 ]
Dwamena, Ben A. [1 ,2 ]
Choudhri, Asim F. [3 ]
Nandalur, Sirisha R. [4 ]
Reddy, Priya
Carlos, Ruth C. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI USA
[2] Ann Arbor Hlth Care Syst, Vet Affairs, Dept Nucl Med, Ann Arbor, MI USA
[3] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA USA
[4] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
meta-analysis; positron emission tomography; coronary disease;
D O I
10.1016/j.acra.2007.08.012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Although myocardial perfusion positron emission tomography (PET), using either cyclotron-produced ammonia or generator-produced rubidium 82, has reported excellent diagnostic capabilities in the detection of coronary artery disease (CAD) in individual studies, the technique is not widely used in practice. This may be driven by cost and availability or by unawareness of performance. The purpose of our study was to conduct an evidence-based evaluation of PET in the diagnosis of CAD. Materials and Methods. We examined studies from January 1977 to July 2007 using MEDLINE and EMBASE. A study was included if it (1) used PET as a diagnostic test for CAD and (2) used catheter x-ray angiography as the reference standard ( >= 50% diameter stenosis). Analysis was performed on a subject and coronary territory level. Results. Nineteen studies (1442 patients) met the inclusion criteria. On a patient. level, PET demonstrated a sensitivity of 0.92 (95% confidence interval [CI]: 0.90-0.94) and specificity of 0.85 (CI: 0.79-0.90), with a positive likelihood ratio (LR+) of 6.2 (CI: 3.3-11.8) and negative likelihood ratio (LR-) of 0.11 (CI: 0.08-0.14). On a coronary territory level (n = 1130), PET showed a sensitivity of 0.81 (CI: 0.77-0.84) and specificity of 0.87 (CI: 0.84-0.90), with an LR+ of 5.9 (CI: 4.5-7.9) and an LR- of 0.19 (CI: 0.09-0.38). Conclusion. PET demonstrates excellent diagnostic properties in the diagnosis of CAD, especially at the patient level. The capabilities appear superior to those reported in meta-analyses for perfusion imaging with TI-201 and sestamibi, or anatomical imaging with coronary MDCT angiography or MRA. Given that previous studies have found PET to be cost-effective and the current findings of excellent sensitivity and specificity, the modality should be more widely considered as an initial test in the diagnosis of CAD.
引用
收藏
页码:444 / 451
页数:8
相关论文
共 50 条
  • [1] Diagnostic Accuracy of Cardiac Positron Emission Tomography Versus Single Photon Emission Computed Tomography for Coronary Artery Disease A Bivariate Meta-Analysis
    Parker, Matthew W.
    Iskandar, Aline
    Limone, Brendan
    Perugini, Andrew
    Kim, Hyejin
    Jones, Charles
    Calamari, Brian
    Coleman, Craig I.
    Heller, Gary V.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2012, 5 (06) : 700 - 707
  • [2] DIAGNOSTIC PERFORMANCE OF CORONARY STRESS FLOW AND CORONARY FLOW RESERVE MEASURED BY POSITRON EMISSION TOMOGRAPHY FOR DETECTION OF OBSTRUCTIVE CORONARY ARTERY DISEASE
    Alexanderson, Erick
    Slomka, Piotr
    Monroy, Andrea
    Berrios, Enrique
    Meave, Aloha
    Gonzalez, Christian
    Germano, Guido
    Berman, Daniel
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A1071 - A1071
  • [3] COMPARATIVE ACCURACY OF POSITRON EMISSION TOMOGRAPHY AND SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY FOR THE DIAGNOSIS OF CORONARY ARTERY DISEASE: A META-ANALYSIS
    Parker, Matthew W.
    Iskandar, Aline
    Limone, Brendan
    Perugini, Andrew
    Calamari, Brian
    Jones, Charles
    Kim, Hyejin
    Coleman, Craig
    Heller, Gary
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1319 - E1319
  • [4] Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease A Meta-Analysis
    Jaarsma, Caroline
    Leiner, Tim
    Bekkers, Sebastiaan C.
    Crijns, Harry J.
    Wildberger, Joachim E.
    Nagel, Eike
    Nelemans, Patricia J.
    Schalla, Simon
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (19) : 1719 - 1728
  • [5] Diagnostic performance of 64-slice multi detector computed tomography for the detection of coronary artery disease: A meta-analysis
    Kim, S. W.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2008, 51 (04) : 544 - 545
  • [6] Positron emission tomography in coronary artery disease
    Gould, K. Lance
    [J]. CURRENT OPINION IN CARDIOLOGY, 2007, 22 (05) : 422 - 428
  • [7] Diagnostic performance of coronary flow reserve ratio for the detection of coronary artery disease on 13N-ammonia positron emission tomography
    Kawamura, G.
    Okayama, H.
    Kawaguchi, N.
    Kido, S.
    Matsuda, K.
    Aono, T.
    Kosaki, T.
    Hosokawa, S.
    Tanaka, Y.
    Shigematsu, T.
    Kawada, Y.
    Hiasa, G.
    Yamada, T.
    Matsuoka, H.
    Kazatani, Y.
    [J]. EUROPEAN HEART JOURNAL, 2018, 39 : 346 - 347
  • [8] Diagnostic Performance of Selective Positron Emission Tomography for Lung Cancer Computed Tomography Screening: a Meta-Analysis
    Chien, C. R.
    Liang, J. A.
    Wang, H. N.
    Lin, C. C.
    Kao, C. H.
    [J]. EUROPEAN JOURNAL OF CANCER, 2011, 47 : S211 - S211
  • [9] Meta-analysis: the detection of pancreatic malignancy with positron emission tomography
    Orlando, LA
    Kulasingam, SL
    Matchar, DB
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2004, 20 (10) : 1063 - 1070
  • [10] Diagnostic performance of computer tomography, magnetic resonance imaging, and positron emission tomography or positron emission tomography/computer tomography for detection of metastatic lymph nodes in patients with cervical cancer: Meta-analysis
    Choi, Hyuck Jae
    Ju, Woong
    Myung, Seung Kwon
    Kim, Yeol
    [J]. CANCER SCIENCE, 2010, 101 (06): : 1471 - 1479