Four-Dimensional MRI Using Three-Dimensional Radial Sampling with Respiratory Self-Gating to Characterize Temporal Phase-Resolved Respiratory Motion in the Abdomen

被引:74
|
作者
Deng, Zixin [1 ,2 ]
Pang, Jianing [1 ,3 ]
Yang, Wensha [4 ]
Yue, Yong [4 ]
Sharif, Behzad [1 ]
Tuli, Richard [4 ]
Li, Debiao [1 ,2 ]
Fraass, Benedick [4 ]
Fan, Zhaoyang [1 ]
机构
[1] Cedars Sinai Med Ctr, Dept Biomed Sci, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA USA
[3] Northwestern Univ, Dept Radiol & Biomed Engn, Chicago, IL 60611 USA
[4] Cedars Sinai Med Ctr, Dept Radiat Oncol, Los Angeles, CA 90048 USA
关键词
4D-MRI; 3D radial sampling; self-gating; respiratory motion; hysteresis; radiotherapy planning; HEART CORONARY MRA; CARDIAC CINE MRI; K-T BLAST; DYNAMIC MRI; RADIOTHERAPY; RECONSTRUCTION; SENSE; COMPENSATION; VARIABILITY; ANGIOGRAPHY;
D O I
10.1002/mrm.25753
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a four-dimensional MRI (4D-MRI) technique to characterize the average respiratory tumor motion for abdominal radiotherapy planning. Methods: A continuous spoiled gradient echo sequence was implemented with 3D radial trajectory and 1D self-gating for respiratory motion detection. Data were retrospectively sorted into different respiratory phases based on their temporal locations within a respiratory cycle, and each phase was reconstructed by means of a self-calibrating CG-SENSE program. Motion phantom, healthy volunteer and patient studies were performed to validate the respiratory motion detected by the proposed method against that from a 2D real-time protocol. Results: The proposed method successfully visualized the respiratory motion in phantom and human subjects. The 4D-MRI and real-time 2D-MRI yielded comparable superior-inferior (SI) motion amplitudes (intraclass correlation = 0.935) with up-to one pixel mean absolute differences in SI displacements over 10 phases and high cross-correlation between phase-resolved displacements (phantom: 0.985; human: 0.937-0.985). Comparable anterior-posterior and left-right displacements of the tumor or gold fiducial between 4D and real-time 2D-MRI were also observed in the two patients, and the hysteresis effect was shown in their 3D trajectories. Conclusion: We demonstrated the feasibility of the proposed 4D-MRI technique to characterize abdominal respiratory motion, which may provide valuable information for radiotherapy planning. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1574 / 1585
页数:12
相关论文
共 50 条
  • [21] Respiratory motion-resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Park, Sung Eun
    Kim, Ho Cheol
    Menini, Anne
    EUROPEAN RADIOLOGY, 2020, 30 (09) : 5130 - 5138
  • [22] Assessment of the Respiratory Motion Induced Inter-Sessional Liver Positional Variation Using Four-Dimensional MR
    Zhou, Y.
    Wong, O. L.
    Yuan, J.
    Cheung, K. Y.
    Yu, S. K.
    MEDICAL PHYSICS, 2017, 44 (06) : 3040 - 3040
  • [23] Three-dimensional reconstruction of in vivo blood vessels in human skin using phase-resolved optical Doppler tomography
    Zhao, YH
    Brecke, KM
    Ren, HW
    Ding, ZH
    Nelson, JS
    Chen, ZP
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2001, 7 (06) : 931 - 935
  • [24] Four-dimensional measurement of intrafractional respiratory motion of pancreatic tumors using a 256 multi-slice CT scanner
    Mori, Shinichiro
    Hara, Ryusuke
    Yanagi, Takeshi
    Sharp, Gregory C.
    Kumagai, Motoki
    Asakura, Hiroshi
    Kishimoto, Riwa
    Yamada, Shigeru
    Kandatsu, Susumu
    Kamada, Tadashi
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 (02) : 231 - 237
  • [25] Four-Dimensional Motion Correction to Distinguish Respiratory From Biological Changes in Treatment Response Assessment Using Molecular Imaging
    Fox, T.
    Crocker, I.
    Schuster, D.
    Curran, W.
    Schreibmann, E.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [26] EVALUATION AND OPTIMIZATION OF THE NEW RESPIRATORY GATING SYSTEM WITH THE THREE-DIMENSIONAL TRACKING OF A SURROGATE USING A WALL MOUNTED CAMERA
    Hrbacek, J.
    Crijns, W.
    Depuydt, T.
    Van den Heuvel, F.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S444 - S445
  • [27] Estimation of relative cardiovascular pressures using time-resolved three-dimensional phase contrast MRI
    Ebbers, T
    Wigström, L
    Bolger, AF
    Engvall, J
    Karlsson, M
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (05) : 872 - 879
  • [28] Respiratory Motion of Lymph Node Stations for Pancreatic Cancer: Analyses Using Contrast-enhanced Four-dimensional Computed Tomography
    Takahashi, S.
    Kinoshita, T.
    Shibata, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E147 - E148
  • [29] Dosimetric Impact of Respiratory Motion During Breast Intensity-modulated Radiation Therapy Using Four-dimensional Dose Calculations
    Choi, Young Eun
    Sung, Kihoon
    Dong, Kap Sang
    Kim, Hyun Ju
    Lim, Young-khi
    ANTICANCER RESEARCH, 2021, 41 (01) : 417 - 427
  • [30] Respiratory motion of lymph node stations in pancreatic cancer: Analyses using contrast-enhanced four-dimensional computed tomography
    Takahashi, Shigeo
    Anada, Masahide
    Kinoshita, Toshifumi
    Shibata, Toru
    RADIOTHERAPY AND ONCOLOGY, 2018, 128 (03) : 569 - 574