Safety and efficacy of using 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate combinations for fixation of displaced diaphyseal clavicle fractures

被引:8
|
作者
Chen, Michael J. [1 ]
DeBaun, Malcolm R. [1 ]
Salazar, Brett P. [1 ]
Lai, Cara [1 ]
Bishop, Julius A. [1 ]
Gardner, Michael J. [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, Med Ctr, 450 Broadway St,Pavil C,4th Floor, Stanford, CA 94063 USA
关键词
Clavicle fracture; Dual plating; Symptomatic implants; Implant removal;
D O I
10.1016/j.injury.2020.01.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: The purpose of this study was to evaluate the safety and efficacy of using lower profile 2.4/2.4 mm and 2.0/2.4 mm dual mini-fragment plate constructs for fixation of diaphyseal clavicle fractures. Methods: This was a retrospective case series of all displaced diaphyseal clavicle fractures treated with 2.4/2.4 and 2.0/2.4 dual mini-fragment plate constructs at a single level-one trauma center. Postoperative complications and fracture healing rates were recorded. A subset of patients with long-term follow up was used to determine the rate of reoperation for symptomatic implant removal. Results: All 36 identified fractures healed without loss of reduction or implant failure. There was one superficial infection and no deep infections or cases of wound dehiscence. Twenty patients from the entire cohort had longer-term follow up available to assess the reoperation rate for symptomatic implant removal. Two patients (10%) underwent symptomatic implant removal, and one patient with retained implants was planning on future removal due to soft-tissue irritation; this combined to a projected reoperation rate of 15% for symptomatic implant removal. Conclusion: Dual mini-fragment plating of diaphyseal clavicle fractures, using 2.4/2.4 mm and 2.0/2.4 mm plate combinations, creates a lower profile construct that reliably maintains fracture reduction to healing, and has a low rate of reoperation for symptomatic implant removal. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:647 / 650
页数:4
相关论文
共 8 条
  • [1] Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates
    Musgrave, DS
    Idler, RS
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04): : 743 - 749
  • [2] Ex Vivo Biomechanical Comparison of the 2.4 mm UniLOCK® Reconstruction Plate Using 2.4 mm Locking Versus Standard Screws for Fixation of Acetabular Osteotomy in Dogs
    Amato, Nicole S.
    Richards, Andrew
    Knight, Trevor A.
    Spector, Daniel
    Boudrieau, Randy J.
    Belkoff, Stephen
    VETERINARY SURGERY, 2008, 37 (08) : 741 - 748
  • [3] A Comparative Evaluation of Fixation Techniques in Anterior Mandibular Fractures Using 2.0 mm Monocortical Titanium Miniplates Versus 2.4 mm Cortical Titanium Lag Screws
    Goyal M.
    Jhamb A.
    Chawla S.
    Marya K.
    Dua J.S.
    Yadav S.
    Journal of Maxillofacial and Oral Surgery, 2012, 11 (4) : 442 - 450
  • [4] Dual mini-fragment plate fixation of midshaft clavicle fractures is biomechanically equivalent to anatomic pre-contoured plating
    Devin P. Ferguson
    Hayden P. Baker
    Daryl Dillman
    Patrick Theriault
    Kelly Trask
    Shelley MacDonald
    Andrew Trenholm
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1109 - 1116
  • [5] Dual mini-fragment plate fixation of midshaft clavicle fractures is biomechanically equivalent to anatomic pre-contoured plating
    Ferguson, Devin P.
    Baker, Hayden P.
    Dillman, Daryl
    Theriault, Patrick
    Trask, Kelly
    MacDonald, Shelley
    Trenholm, Andrew
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (04): : 1109 - 1116
  • [6] A biomechanic comparison of an internal radiocarpal-spanning 2.4-mm locking plate and external fixation in a model of distal radius fractures
    Wolf, Jonathon C.
    Weil, Wayne M.
    Hanel, Douglas P.
    Trumble, Thomas E.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10): : 1578 - 1586
  • [7] Dorsal and Volar 2.4-mm Locking Plate Fixation for AO Type C3 Dorsally Comminuted Distal Radius Fractures
    Chou, Ying-Chao
    Chen, Alvin Chao-Yu
    Chen, Chun-Ying
    Hsu, Yung-Heng
    Wu, Chi-Chuan
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (06): : 974 - 981
  • [8] Dorsal 2.4 mm locking plate fixation of intra-articular fractures with articular impaction and dorsal displacement of the distal radius: a propos of 21 cases
    De Smet, Alexander
    Kampfen, Stephane
    Van Aaken, Jan
    Beaulieu, Jean-Yves
    SWISS MEDICAL WEEKLY, 2011, 141 : 23S - 23S