A Comparative Evaluation of Fixation Techniques in Anterior Mandibular Fractures Using 2.0 mm Monocortical Titanium Miniplates Versus 2.4 mm Cortical Titanium Lag Screws

被引:12
|
作者
Goyal M. [1 ]
Jhamb A. [1 ]
Chawla S. [1 ]
Marya K. [1 ]
Dua J.S. [1 ]
Yadav S. [1 ]
机构
[1] Department of Oral & Maxillofacial Surgery, Santosh Dental & Medical College & Hospital, No.1 Santosh Nagar, Pratap Vihar, Ghaziabad, Delhi NCR
关键词
Compression osteosynthesis; Lag screw technique; Mandibular fractures; Miniplates;
D O I
10.1007/s12663-012-0342-1
中图分类号
学科分类号
摘要
Objective: To compare the efficacy and surgical outcome of treatment of anterior mandibular fracture using either 2.0 mm titanium miniplate or 2.4 mm titanium lag screw technique. Materials and Methods: A total of 30 patients were managed by open reduction and internal fixation utilizing the miniplate and lag screw technique for fractures of anterior mandible. The patients were randomly divided into two groups. Group I: (15 patients) were treated with Leibinger, 2.0 mm titanium mini plates system with self-tapping screws and Group II: (15 patients) were treated with 2.4 mm cortical lag screw (Synthes). Intraoperatively duration of surgery was measured from the time incision was placed till the closure of wound. Subsequent follow up was done at 3, 6, 12, 24 weeks, postoperatively. During every follow up, patients were assessed clinically for malocclusion, neurosensory deficit, biting efficiency, implant failure, mal-union/non-union. Pre and postoperative radiographs were taken to assess the gap between fracture segments. Results were evaluated using Chi square and the unpaired t test. Results: In our study, the mean duration of surgery (hours) was 1.97 ± 0.52 for group I and 1.26 ± 0.55 for group II. The difference was found to be statistically significant (p value 0.001). i.e. more time was taken in case of surgery with mini-plates when compared to the lag screw. Short surgical procedure reduces the incidence of infectious complications, which significantly lowers the financial burden. The mean post-operative radiographic distance between all measuring points were considerably more in case of mini-plate group as compared to lag screw group. Lag screw group showed faster improvement in terms of biting efficiency as compared to mini-plate group which showed a tendency to masticate only medium hard food items by 24 weeks. In both groups, no postoperative malocclusion was noted. In initial weeks, neurosensory deficit was seen more in mini-plate group as compared to lag screw group but after six weeks all patients showed improvement in neurosensory function without any permanent nerve damage. Conclusion: According to this prospective study, rigid internal fixation provided by lag screw technique for anterior mandibular fracture offers several advantages over conventional bone plating. It is an excellent means of achieving rapid and safe fixation which is followed by primary bone healing in anterior mandibular fractures, without any major complications. © 2012, Association of Oral and Maxillofacial Surgeons of India.
引用
收藏
页码:442 / 450
页数:8
相关论文
共 15 条
  • [1] A Comparative Evaluation of 2.0mm Two-Dimensional Miniplates Versus 2.0mm Three-Dimensional Miniplates in Mandibular Fractures
    Sarepally, Godvine
    Seethamsetty, Swetcha
    Karpe, Tanveer
    Nasyam, Fazil A.
    Fatima, Umayra
    Fatema, Raia
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (01)
  • [2] Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates & 3-D Locking Plates
    Manoj Goyal
    Karan Marya
    Sonia Chawla
    Richa Pandey
    Journal of Maxillofacial and Oral Surgery, 2011, 10 (4) : 316 - 320
  • [3] Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates & 3-D Locking Plates
    Goyal, Manoj
    Marya, Karan
    Chawla, Sonia
    Pandey, Richa
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2011, 10 (04): : 316 - 320
  • [4] Mandibular Osteosynthesis: A Comparative Evaluation of Two Different Fixation Systems Using 2.0 mm Titanium Miniplates and 3-D Locking Plates
    Goyal M.
    Marya K.
    Chawla S.
    Pandey R.
    Journal of Maxillofacial and Oral Surgery, 2011, 10 (1) : 32 - 37
  • [5] Titanium Lag Screw Versus Miniplate Fixation in the Treatment of Anterior Mandibular Fractures
    Tiwari, Manish
    Meshram, Vikas
    Lambade, Pravin
    Fernandes, Gabriela
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 77 (05) : 1031 - 1039
  • [6] Application of 2.0 mm Titanium Plates in Rigid Internal Fixation of Mandibular Angle Fractures
    Sabhlok S.
    Waknis P.
    Bhagwat A.
    Journal of Maxillofacial and Oral Surgery, 2010, 9 (4) : 339 - 343
  • [7] A comparative analysis of the efficacy of cortical screws as lag screws and miniplates for internal fixation of mandibular symphyseal region fractures: a randomized prospective study
    Agnihotri, A.
    Prabhu, S.
    Thomas, S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (01) : 22 - 28
  • [8] Comparative in vitro mechanical evaluation of techniques using a 2.0 mm locking fixation system for simulated fractures of the mandibular body
    de Medeiros, Raquel Correia
    de Moura, Andrezza Lauria
    Sawazaki, Renato
    Fernandes Moreira, Roger William
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2015, 43 (03) : 302 - 305
  • [9] COMPARATIVE EVALUATION OF THE MECHANICAL PROPERTIES OF RESORBABLE AND TITANIUM MINIPLATES USED FOR FIXATION OF MANDIBULAR CONDYLE FRACTURES
    Cansiz, Erol
    Dogru, Suzan Cansel
    Arslan, Yunus Ziya
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (02)
  • [10] Evaluation of two internal fixation techniques for mandibular parasymphyseal fractures comparing conventional titanium miniplates with customised titanium CRB omega miniplates: a prospective study
    Bande, C. R.
    Kurawar, K. R.
    Mishra, A.
    Joshi, A.
    Goel, M.
    Mahajan, M. R.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2018, 56 (06): : 520 - 524