A novel high-throughput assay for the measurement of salivary progesterone by liquid chromatography tandem mass spectrometry

被引:9
|
作者
Schiffer, Lina [1 ,2 ]
Adaway, Joanne E. [3 ]
Baranowski, Elizabeth S. [1 ,2 ]
Arlt, Wiebke [1 ,2 ]
Keevil, Brian G. [3 ]
机构
[1] Univ Birmingham, Inst Metab & Syst Res, Birmingham, W Midlands, England
[2] Birmingham Hlth Partners, Ctr Endocrinol Diabet & Metab, Birmingham, W Midlands, England
[3] Manchester Univ NHS Trust, Manchester Acad Hlth Sci Ctr, Wythenshawe Hosp, Biochem Dept, Manchester, Lancs, England
基金
英国医学研究理事会;
关键词
Progesterone; saliva; liquid chromatography tandem mass spectrometry; DIRECT RADIOIMMUNOASSAY; ENZYME-IMMUNOASSAY; COLLECTION DEVICES; STEROID-HORMONES; PRETERM BIRTH; PLASMA; PHASE; WOMEN; VALIDATION; ADULT;
D O I
10.1177/0004563218780904
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Liquid chromatography tandem mass spectrometry (LC-MS/MS) enables specific and sensitive quantification of steroids with a high throughput. Saliva sampling is advantageous for multisample profiling over longer periods of time, as it is non-invasive, cheap, can be carried out at home and does not require the attendance of clinical personnel. We developed a rapid LC-MS/MS for the measurement of salivary progesterone, frequently assessed as ovulation marker in patients desiring fertility. Methods Samples (300 mu L) were prepared by supported liquid extraction using dichloromethane and were reconstituted in 40% methanol. Chromatography was performed using a C8 column with a water/methanol gradient containing 0.1% formic acid and 2 mmol/L ammonium acetate. Quantification was performed with a Waters TQ-S mass spectrometer. Results Total run time was 5.5 min. The lower limit of quantification was 20 pmol/L (1.2 fmol on column). Inter- and intra-assay comparison showed coefficients of variation and bias between measured and nominal concentrations of less than 11%. Mean recovery was 91%. Interference with a large set of natural and synthetic steroids was excluded. The assay was successfully applied to measure progesterone variation during the menstrual cycle (n = 9) and diurnal variations during luteal phase (n = 7) in regularly cycling women. Discussion We present a novel LC-MS/MS assay for the determination of salivary progesterone with high-throughput potential. The applicability of the assay for progesterone profiling during the menstrual cycle is demonstrated.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [31] High-throughput quantification of the levels and labeling abundance of free amino acids by liquid chromatography tandem mass spectrometry
    Cocuron, Jean-Christophe
    Tsogtbaatar, Enkhtuul
    Alonso, Ana P.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1490 : 148 - 155
  • [32] Approach to improve compound recovery in a high-throughput Caco-2 permeability assay supported by liquid chromatography-tandem mass spectrometry
    Cai, Xianmei
    Walker, Aaron
    Cheng, Charles
    Paiva, Anthony
    Li, Ying
    Kolb, Janet
    Herbst, John
    Shou, Wilson
    Weller, Harold
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2012, 101 (08) : 2755 - 2762
  • [33] Quantitative Insulin Analysis Using Liquid Chromatography-Tandem Mass Spectrometry in a High-Throughput Clinical Laboratory
    Chen, Zhaohui
    Caulfield, Michael P.
    McPhaul, Michael J.
    Reitz, Richard E.
    Taylor, Steven W.
    Clarke, Nigel J.
    CLINICAL CHEMISTRY, 2013, 59 (09) : 1349 - 1356
  • [34] High-throughput screening of corticosteroids and basic drugs in horse urine by liquid chromatography-tandem mass spectrometry
    Leung, GNW
    Chung, EW
    Ho, ENM
    Kwok, WH
    Leung, DKK
    Tang, FPW
    Wan, TSM
    Yu, NH
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 825 (01): : 47 - 56
  • [35] High-throughput simultaneous analysis of pesticides by supercritical fluid chromatography/tandem mass spectrometry
    Ishibashi, Megumi
    Ando, Takashi
    Sakai, Miho
    Matsubara, Atsuki
    Uchikata, Takato
    Fukusaki, Eiichiro
    Bamba, Takeshi
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1266 : 143 - 148
  • [37] Bioanalytical applications of 'fast chromatography' to high-throughput liquid chromatography/tandem mass spectrometric quantitation
    Romanyshyn, L
    Tiller, PR
    Hop, CECA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (18) : 1662 - 1668
  • [38] High-throughput quantification of soy isoflavones in human and rodent blood using liquid chromatography with electrospray mass spectrometry and tandem mass spectrometry detection
    Twaddle, NC
    Churchwell, MI
    Doerge, DR
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 777 (1-2): : 139 - 145
  • [39] High-throughput and cost-effective global DNA methylation assay by liquid chromatography-mass spectrometry
    Li, Xingnan
    Franke, Adrian A.
    ANALYTICA CHIMICA ACTA, 2011, 703 (01) : 58 - 63
  • [40] Development and validation of a liquid chromatography tandem mass spectrometry assay for the measurement of faecal metronidazole
    Jeffery, Jinny
    Vincent, Zoe J.
    Ayling, Ruth M.
    Lewis, Stephen J.
    CLINICAL BIOCHEMISTRY, 2017, 50 (06) : 323 - 330