A novel high-throughput assay for the measurement of salivary progesterone by liquid chromatography tandem mass spectrometry

被引:9
|
作者
Schiffer, Lina [1 ,2 ]
Adaway, Joanne E. [3 ]
Baranowski, Elizabeth S. [1 ,2 ]
Arlt, Wiebke [1 ,2 ]
Keevil, Brian G. [3 ]
机构
[1] Univ Birmingham, Inst Metab & Syst Res, Birmingham, W Midlands, England
[2] Birmingham Hlth Partners, Ctr Endocrinol Diabet & Metab, Birmingham, W Midlands, England
[3] Manchester Univ NHS Trust, Manchester Acad Hlth Sci Ctr, Wythenshawe Hosp, Biochem Dept, Manchester, Lancs, England
基金
英国医学研究理事会;
关键词
Progesterone; saliva; liquid chromatography tandem mass spectrometry; DIRECT RADIOIMMUNOASSAY; ENZYME-IMMUNOASSAY; COLLECTION DEVICES; STEROID-HORMONES; PRETERM BIRTH; PLASMA; PHASE; WOMEN; VALIDATION; ADULT;
D O I
10.1177/0004563218780904
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Liquid chromatography tandem mass spectrometry (LC-MS/MS) enables specific and sensitive quantification of steroids with a high throughput. Saliva sampling is advantageous for multisample profiling over longer periods of time, as it is non-invasive, cheap, can be carried out at home and does not require the attendance of clinical personnel. We developed a rapid LC-MS/MS for the measurement of salivary progesterone, frequently assessed as ovulation marker in patients desiring fertility. Methods Samples (300 mu L) were prepared by supported liquid extraction using dichloromethane and were reconstituted in 40% methanol. Chromatography was performed using a C8 column with a water/methanol gradient containing 0.1% formic acid and 2 mmol/L ammonium acetate. Quantification was performed with a Waters TQ-S mass spectrometer. Results Total run time was 5.5 min. The lower limit of quantification was 20 pmol/L (1.2 fmol on column). Inter- and intra-assay comparison showed coefficients of variation and bias between measured and nominal concentrations of less than 11%. Mean recovery was 91%. Interference with a large set of natural and synthetic steroids was excluded. The assay was successfully applied to measure progesterone variation during the menstrual cycle (n = 9) and diurnal variations during luteal phase (n = 7) in regularly cycling women. Discussion We present a novel LC-MS/MS assay for the determination of salivary progesterone with high-throughput potential. The applicability of the assay for progesterone profiling during the menstrual cycle is demonstrated.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [21] High-throughput and simultaneous measurement of homocysteine and cysteine in human plasma and urine by liquid chromatography-electro spray tandem mass spectrometry
    Rafii, Mahroukh
    Elango, Rajavel
    Courtney-Martin, Glenda
    House, James D.
    Fisher, Lawrence
    Pencharz, Paul B.
    ANALYTICAL BIOCHEMISTRY, 2007, 371 (01) : 71 - 81
  • [22] Salivary testosterone measurement by liquid chromatography tandem mass spectrometry in adult males and females
    Keevil, B. G.
    MacDonald, P.
    Macdowall, W.
    Lee, D. M.
    Wu, F. C. W.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2014, 51 (03) : 368 - 378
  • [23] Pitfall in the high-throughput quantification of whole blood cyclosporin A using liquid chromatography-tandem mass spectrometry
    Vogeser, M
    Spöhrer, U
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (04) : 400 - 402
  • [24] Minimization of carryover for high-throughput liquid chromatography with tandem mass spectrometry analysis of 14 mycotoxins in corn grits
    Tamura, Masayoshi
    Matsumoto, Keiko
    Watanabe, Jun
    Iida, Junko
    Nagatomi, Yasushi
    Mochizuki, Naoki
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (13) : 1552 - 1560
  • [25] High-throughput quantification of perindopril in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Komarneni, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) : 1864 - 1870
  • [26] Multianalyte, high-throughput liquid chromatography tandem mass spectrometry method for the sensitive determination of fungicides and insecticides in wine
    Gabriela Castro
    Leticia Pérez-Mayán
    Tamara Rodríguez-Cabo
    Isaac Rodríguez
    Maria Ramil
    Rafael Cela
    Analytical and Bioanalytical Chemistry, 2018, 410 : 1139 - 1150
  • [27] High-throughput determination of neonicotinoid insecticides in pollen and nectar using liquid chromatography with tandem mass spectrometry detection
    Warnick, Joe
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [28] Multianalyte, high-throughput liquid chromatography tandem mass spectrometry method for the sensitive determination of fungicides and insecticides in wine
    Castro, Gabriela
    Perez-Mayan, Leticia
    Rodriguez-Cabo, Tamara
    Rodriguez, Isaac
    Ramil, Maria
    Cela, Rafael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (03) : 1139 - 1150
  • [29] A simple high-throughput method for the determination of plasma methylmalonic acid by liquid chromatography-tandem mass spectrometry
    Blom, Henk J.
    van Rooij, Arno
    Hogeveen, Marije
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (05) : 645 - 650
  • [30] Sphingolipidomics: High-throughput, structure-specific, and quantitative analysis of sphingolipids by liquid chromatography tandem mass spectrometry
    Merrill, AH
    Sullards, MC
    Allegood, JC
    Kelly, S
    Wang, E
    METHODS, 2005, 36 (02) : 207 - 224