Verification of IMRT dose distributions using a tissue equivalent plastic scintillator based dosimetry system

被引:1
|
作者
Petric, MP
Robar, JL
Clark, BG
机构
[1] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
[2] Nova Scotia Canc Ctr, Halifax, NS, Canada
关键词
D O I
10.1118/1.1997417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Intensity modulated radiation therapy (IMRT) offers the potential for improved target coverage and increased normal tissue sparing compared with conformal radiotherapy. The complex fluence maps used in IMRT, however, lead to more challenging quality assurance with dose verification being labor‐intensive and time consuming. An IMRT dose verification system has been developed using tissue equivalent plastic scintillator that provides easy to acquire, rapid electronic and directly digital dose measurements of a 2D plane perpendicular to the beam. Method and Materials: The prototype system consists of a water‐filled Lucite phantom with a scintillator screen built into the top surface. The phantom contains a plastic mirror to reflect scintillation light towards a viewing window where it is captured using a CCD camera and a personal computer. Optical photon spread is removed using a micro‐louvre optical collimator and by deconvolving a glare kernel from the raw images. System calibration is performed using radiation fields of known dose distributions. The system was evaluated by verifying a 5‐field IMRT plan and comparing the results to a 2‐D film dosimetry verification of the same plan. Resultant distributions were compared using 1‐D dose profiles, 2‐D dose difference maps and gamma factor analysis. A comparison of the time requirements for verification with each system was also performed. Results: Preliminary results acquired with the new verification system indicate agreement within 5% of 2‐D film dosimetry. Gamma factor analysis shows excellent agreement over most of the distributions. The timing comparison of the verification systems highlights the efficiency of the new scintillator system for IMRT verification with a 50% reduction in time. Conclusion: Results from a 5‐field IMRT plan verification using the new scintillator based system are very promising. With further development this system promises to provide a fast, directly digital, and tissue equivalent alternative to current IMRT verification systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1891 / 1891
页数:1
相关论文
共 50 条
  • [1] Characterization of a tissue equivalent plastic scintillator dosimetry system
    Petric, M
    Robar, J
    Clark, B
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2427 - 2427
  • [2] Development and characterization of a tissue equivalent plastic scintillator based dosimetry system
    Petric, MP
    Robar, JL
    Clark, BG
    [J]. MEDICAL PHYSICS, 2006, 33 (01) : 96 - 105
  • [3] Acrylonitrile Butadiene Styrene (ABS) plastic-based low cost tissue equivalent phantom for verification dosimetry in IMRT
    Kumar, Rajesh
    Sharma, S. D.
    Despande, Sudesh
    Ghadi, Yogesh
    Shaiju, V. S.
    Amols, H. I.
    Mayya, Y. S.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 24 - 32
  • [4] Dose verification of radiotherapy for lung cancer by using plastic scintillator dosimetry and a heterogeneous phantom
    Ottosson, W.
    Behrens, C. F.
    Andersen, C. E.
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [5] Photon spectra and dose measurements using a tissue-equivalent plastic scintillator
    Lobdell, JL
    Hertel, NE
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 72 (02) : 95 - 103
  • [6] Verification of IMRT dose distributions using a water beam imaging system
    Li, JS
    Boyer, AL
    Ma, CM
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2466 - 2474
  • [7] Verification of IMRT dose distributions using a water beam imaging system
    Li, JS
    Ozhasoglu, C
    Deng, J
    Boyer, AL
    Ma, CM
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1158 - 1161
  • [8] Alanine dosimetry in dose verification for IMRT
    Schaeken, B.
    De Ost, B.
    Van Gestel, D.
    Meijnders, P.
    Jacobs, I.
    Goor, C.
    Vanderkam, S.
    Coelmont, A.
    Van den Weyngaert, D.
    Schaeken, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S365 - S366
  • [9] A study on absorbed dose measurement using a butyl acrylate-based plastic scintillator as a tissue-equivalent detector
    Kim, Gwangsoo
    Kim, Hongjoo
    Kim, Sunghwan
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 85 (03) : 213 - 218
  • [10] DEPTH DOSE DETERMINATION FOR A MIXED RADIATION FIELD USING A THIN PLASTIC SCINTILLATOR DOSIMETRY SYSTEM
    Aydarous, Abdulkadir
    Waker, Anthony
    [J]. NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (01): : 20 - 27