Verification of IMRT dose distributions using a tissue equivalent plastic scintillator based dosimetry system

被引:1
|
作者
Petric, MP
Robar, JL
Clark, BG
机构
[1] British Columbia Canc Agcy, Vancouver, BC V5Z 4E6, Canada
[2] Nova Scotia Canc Ctr, Halifax, NS, Canada
关键词
D O I
10.1118/1.1997417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Intensity modulated radiation therapy (IMRT) offers the potential for improved target coverage and increased normal tissue sparing compared with conformal radiotherapy. The complex fluence maps used in IMRT, however, lead to more challenging quality assurance with dose verification being labor‐intensive and time consuming. An IMRT dose verification system has been developed using tissue equivalent plastic scintillator that provides easy to acquire, rapid electronic and directly digital dose measurements of a 2D plane perpendicular to the beam. Method and Materials: The prototype system consists of a water‐filled Lucite phantom with a scintillator screen built into the top surface. The phantom contains a plastic mirror to reflect scintillation light towards a viewing window where it is captured using a CCD camera and a personal computer. Optical photon spread is removed using a micro‐louvre optical collimator and by deconvolving a glare kernel from the raw images. System calibration is performed using radiation fields of known dose distributions. The system was evaluated by verifying a 5‐field IMRT plan and comparing the results to a 2‐D film dosimetry verification of the same plan. Resultant distributions were compared using 1‐D dose profiles, 2‐D dose difference maps and gamma factor analysis. A comparison of the time requirements for verification with each system was also performed. Results: Preliminary results acquired with the new verification system indicate agreement within 5% of 2‐D film dosimetry. Gamma factor analysis shows excellent agreement over most of the distributions. The timing comparison of the verification systems highlights the efficiency of the new scintillator system for IMRT verification with a 50% reduction in time. Conclusion: Results from a 5‐field IMRT plan verification using the new scintillator based system are very promising. With further development this system promises to provide a fast, directly digital, and tissue equivalent alternative to current IMRT verification systems. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1891 / 1891
页数:1
相关论文
共 50 条
  • [21] Improvements to an optical scintillator imaging-based tissue dosimetry system
    Tendler, Irwin I.
    Bruza, Petr
    Jermyn, Michael
    Fleury, Antoine
    Williams, Benjamin B.
    Jarvis, Lesley A.
    Pogue, Brian W.
    Gladstone, David J.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (07)
  • [22] IMRT Verification using Portal Dosimetry and a 3D Planning System
    Cufflin, R. S.
    Spezi, E.
    Lewis, D. G.
    [J]. CLINICAL ONCOLOGY, 2009, 21 (03) : 264 - 265
  • [23] A TAR-based system for automatic IMRT dose verification
    Morrill, S
    Bayouth, J
    Wendt, D
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1417 - 1417
  • [24] A numerical analysis to quantify the discrepancy in dose distributions between IMRT planning system and film dosimetry
    Wu, J
    Lo, Y
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1496 - 1496
  • [25] Large scale implementation of clinical EPID dosimetry for IMRT dose verification
    Mans, A.
    Stroom, J.
    Tielenburg, R.
    Vijlbrief, R.
    Buijs, M.
    Wendling, M.
    McDermott, L.
    Van Herk, M.
    Mijnheer, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S99 - S99
  • [26] The effects of incidence angle on film dosimetry and their consequences in IMRT dose verification
    Srivastava, R. P.
    De Wagter, C.
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 6129 - 6138
  • [27] A versatile tool for IMRT 3-D dose distribution verification using film dosimetry
    Shen, S
    Duan, J
    Fiveash, J
    Popple, R
    Preek, P
    Brezovich, I
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1261 - 1261
  • [28] DYNAMIC IMRT SPLIT BEAM TECHNIQUE VERIFICATION USING EPID BASED DOSIMETRY
    Richart Sancho, J.
    Perez-Calatayud, J.
    Granero, D.
    Ballester, F.
    Santos Ortega, M.
    Rodriguez Villalba, S.
    Navarro Gala, M. A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S455 - S455
  • [29] Dynamic IMRT Split Beam Technique Verification Using EPID Based Dosimetry
    Richart, J.
    Perez-Calatayud, J.
    Granero, D.
    Ballester, F.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [30] Verification of IMRT dose distributions with EDR2 films
    Smulders, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S38 - S38