Diagnostic performance and validation of autoantibody testing in myositis by a commercial line blot assay

被引:125
|
作者
Ghirardello, Anna [1 ]
Rampudda, Mariaelisa [1 ]
Ekholm, Louise [2 ,3 ]
Bassi, Nicola [1 ]
Tarricone, Elena [1 ]
Zampieri, Sandra [1 ]
Zen, Margherita [1 ]
Vattemi, Gaetano A. [4 ]
Lundberg, Ingrid E. [2 ,3 ]
Doria, Andrea [1 ]
机构
[1] Univ Padua, Dept Clin & Expt Med, Div Rheumatol, I-35128 Padua, Italy
[2] Karolinska Univ Hosp, Dept Med, Rheumatoloy Unit, Solna, Sweden
[3] Karolinska Inst, Stockholm, Sweden
[4] Univ Verona, Dept Neurol & Opt Sci, Clin Neurol Sect, I-37100 Verona, Italy
关键词
Autoimmune myositis; Myositis-specific autoantibodies; Serological methods; Diagnostic accuracy; Immunoprecipitation; Immunoblot; Line blot; ANTI-KU ANTIBODIES; CLASSIFICATION; INFECTIONS; UTILITY;
D O I
10.1093/rheumatology/keq281
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods. IgG antibodies against Jo-1, PL-7, PL-12, PM/Scl, Ku, Mi-2 and Ro52 antigens were detected by a line blot and in-house RNA immunoprecipitation or immunoblot. We tested sera from 208 IIM patients, 50 healthy subjects and 180 control patients (11 non-autoimmune myopathy, 23 muscular dystrophy, 11 UCTD, 68 SLE, 36 SSc, 22 SS and 9 arthropathy). Results. MSAs or MAAs were detected in 98 (47%) out of the 208 IIM patients by line blot: anti-Jo-1 in 43 (21%), anti-PL-7 or anti-PL-12 in 8 (4%), anti-Mi-2 in 9 (4%), anti-PM/Scl in 9 (4%), anti-Ku in 10 (5%) and anti-Ro52 in 49 (24%). Overall specificity was: 100% for anti-Jo-1, anti-PL-7 or PL-12 and anti-PM/Scl; 96% for anti-Ku; 98% for anti-Mi-2; and 76% for anti-Ro52. In-house testing confirmed line blot results regarding anti-Jo-1, anti-PM/Scl and anti-Ku, while it was more accurate than line blot in detecting anti-Mi-2 (7 vs 4% sensitivity, 100 vs 98% specificity), and anti-aminoacyl-tRNA synthetase (anti-ARS) non-Jo-1 antibodies (11 vs 4% sensitivity, 97 vs 99% specificity). Conclusions. Line blot could be a suitable serological test in the diagnostic workup for myositis, and it represents a reliable alternative to more time-consuming procedures. Continuous effort is recommended in order to improve its accuracy.
引用
收藏
页码:2370 / 2374
页数:5
相关论文
共 50 条
  • [41] Evaluation of the diagnostic performance of a commercial molecular assay for the screening of suspected monkeypox cases in Sri Lanka
    Harshani, H. B. C.
    Liyanage, G. A.
    Ruwan, D. V. R. G.
    Samaraweera, U. K. I. U.
    Abeynayake, J. I.
    INFECTIOUS MEDICINE, 2023, 2 (02): : 136 - 142
  • [42] The Diagnostic Performance of the GenoType MTBDRplus Version 2 Line Probe Assay Is Equivalent to That of the Xpert MTB/RIF Assay
    Barnard, M.
    Gey van Pittius, N. C.
    van Helden, P. D.
    Bosman, M.
    Coetzee, G.
    Warren, R. M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (11) : 3712 - 3716
  • [43] Performance of CCP assay in an updated series of biopsy samples obtained from commercial testing.
    Davis, John W.
    Crawford, E. David
    Shore, Neal
    Scardino, Peter T.
    Tward, Jonathan D.
    Harrison, Lowndes
    Evans, Brent
    FitzGerald, Lisa
    Stone, Steven
    Brawer, Michael K.
    JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (15)
  • [44] Performance of CCP assay in an updated series of biopsy samples obtained from commercial testing.
    Crawford, E. David
    Shore, Neal
    Scardino, Peter T.
    Davis, John W.
    Tward, Jonathan D.
    Harrison, Lowndes
    Evans, Brent
    Fitzgerald, Lisa
    Stone, Steven
    Brawer, Michael K.
    JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (07)
  • [45] "Improved basic performance of iTACT-HBcrAg assay" and "Using a commercial diagnostic assay requires compliance with the manufacturer's recommendations"
    Lim, Seng Gee
    Yeo, Ee Jin
    Adraneda, Celina
    Tan, Yong Chuan
    JOURNAL OF HEPATOLOGY, 2023, 79 (03) : E136 - E137
  • [46] Performance evaluation of a line blot assay system for detection of anti-PM-Scl antibody in Japanese patients with systemic sclerosis
    Hamaguchi, Yasuhito
    Kuwana, Masataka
    Takehara, Kazuhiko
    INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2019, 22 (09) : 1746 - 1751
  • [47] Mycoplasma bovis real-time polymerase chain reaction assay validation and diagnostic performance
    Clothier, Kristin A.
    Jordan, Dianna M.
    Thompson, Curtis J.
    Kinyon, Joann M.
    Frana, Timothy S.
    Strait, Erin L.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2010, 22 (06) : 956 - 960
  • [48] Performance of a fourth-generation HIV screening assay and an alternative HIV diagnostic testing algorithm
    Nasrullah, Muazzam
    Wesolowski, Laura G.
    Meyer, William A., III
    Owen, S. Michele
    Masciotra, Silvina
    Vorwald, Craig
    Becker, William J.
    Branson, Bernard M.
    AIDS, 2013, 27 (05) : 731 - 737
  • [49] Evaluation of Diagnostic Performance of Line Probe Assay on Smear-Negative Samples of Pulmonary Tuberculosis
    Nandwani, Sumi
    Singhal, Sanjay
    Gothi, Dipti
    Singhal, Ritu
    Perween, Naz
    Gupta, Kavita
    Bir, Raunak
    Gunasekaran, Jayanthi
    Soni, Anushka
    Chaudhary, Urmila
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [50] How to increase diagnostic yield of the aquaporin-4 autoantibody assay? Utility of complementary tests, use of positive controls and follow up testing
    Kim, S.
    Kim, Y.
    Ahn, S.
    Yoon, B.
    Sung, J.
    Lee, K.
    Jung, K.
    Park, K.
    MULTIPLE SCLEROSIS JOURNAL, 2013, 19 (11) : 75 - 76