Locking Plates With Computationally Enhanced Screw Trajectories Provide Superior Biomechanical Fixation Stability of Complex Proximal Humerus Fractures

被引:4
|
作者
Mischler, Dominic [1 ]
Schader, Jana Felicitas [1 ]
Dauwe, Jan [1 ,2 ]
Tenisch, Lara [1 ]
Gueorguiev, Boyko [1 ]
Windolf, Markus [1 ]
Varga, Peter [1 ]
机构
[1] AO Res Inst Davos, Davos, Switzerland
[2] UZ Leuven, Dept Trauma Surg, Leuven, Belgium
关键词
bone fracture (MeSH ID; D050723); osteosynthesis; implant optimization; 3D-printing; finite element analysis; fixation failure; ANGULAR STABLE PLATE; NONOPERATIVE TREATMENT; INTERNAL-FIXATION; ELDERLY-PATIENTS; PERFORATION; STIFFNESS; SYSTEMS; ADULTS; LOAD;
D O I
10.3389/fbioe.2022.919721
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Joint-preserving surgical treatment of complex unstable proximal humerus fractures remains challenging, with high failure rates even following state-of-the-art locked plating. Enhancement of implants could help improve outcomes. By overcoming limitations of conventional biomechanical testing, finite element (FE) analysis enables design optimization but requires stringent validation. This study aimed to computationally enhance the design of an existing locking plate to provide superior fixation stability and evaluate the benefit experimentally in a matched-pair fashion. Further aims were the evaluation of instrumentation accuracy and its potential influence on the specimen-specific predictive ability of FE. Screw trajectories of an existing commercial plate were adjusted to reduce the predicted cyclic cut-out failure risk and define the enhanced (EH) implant design based on results of a previous parametric FE study using 19 left proximal humerus models (Set A). Superiority of EH versus the original (OG) design was tested using nine pairs of human proximal humeri (N = 18, Set B). Specimen-specific CT-based virtual preoperative planning defined osteotomies replicating a complex 3-part fracture and fixation with a locking plate using six screws. Bone specimens were prepared, osteotomized and instrumented according to the preoperative plan via a standardized procedure utilizing 3D-printed guides. Cut-out failure of OG and EH implant designs was compared in paired groups with both FE analysis and cyclic biomechanical testing. The computationally enhanced implant configuration achieved significantly more cycles to cut-out failure compared to the standard OG design (p < 0.01), confirming the significantly lower peri-implant bone strain predicted by FE for the EH versus OG groups (p < 0.001). The magnitude of instrumentation inaccuracies was small but had a significant effect on the predicted failure risk (p < 0.01). The sample-specific FE predictions strongly correlated with the experimental results (R-2 = 0.70) when incorporating instrumentation inaccuracies. These findings demonstrate the power and validity of FE simulations in improving implant designs towards superior fixation stability of proximal humerus fractures. Computational optimization could be performed involving further implant features and help decrease failure rates. The results underline the importance of accurate surgical execution of implant fixations and the need for high consistency in validation studies.
引用
收藏
页数:11
相关论文
共 47 条
  • [1] The application of a dual-lead locking screw could enhance the reduction and fixation stability of the proximal humerus fractures: a biomechanical evaluation
    Lee, Eunju
    Jeong, Hyeon Jang
    Lee, Yeon Soo
    Oh, Joo Han
    FRONTIERS IN SURGERY, 2024, 11
  • [2] Enhancing fixation stability in proximal humerus fractures: screw orientation optimization in PHILOS plates through finite element analysis and biomechanical testing
    Jichao Liu
    Ziyan Zhang
    Peng Li
    Chengdong Piao
    Scientific Reports, 14 (1)
  • [3] Functional outcomes of locking plate fixation in complex proximal humerus fractures
    Shaikh, Saeed Ahmed
    Arain, Muhammad Arif
    Rehman, Muhammad Mansoor
    Ahmed, Nadeem
    Samejo, Muhammad Qasim Ali
    RAWAL MEDICAL JOURNAL, 2020, 45 (03): : 633 - 636
  • [4] Computational optimisation of screw orientations for improved locking plate fixation of proximal humerus fractures
    Mischler, Dominic
    Windolf, Markus
    Gueorguiev, Boyko
    Nijs, Stefaan
    Varga, Peter
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 25 : 96 - 104
  • [5] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Jabran, Ali
    Peach, Chris
    Zou, Zhenmin
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [6] How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data
    Schliemann, Benedikt
    Waehnert, Dirk
    Theisen, Christina
    Herbort, Mirco
    Koesters, Clemens
    Raschke, Michael J.
    Weimann, Andre
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (07): : 1207 - 1214
  • [7] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Ali Jabran
    Chris Peach
    Zhenmin Zou
    Lei Ren
    BioMedical Engineering OnLine, 17
  • [8] Does minimally invasive external fixation of proximal humerus fractures provide adequate stability? A biomechanical in vitro study
    Markus Greinwald
    Franz Matschl
    Stephan Regenbogen
    Robert Pätzold
    Davide Blonna
    Peter Augat
    BMC Musculoskeletal Disorders, 25 (1)
  • [9] IMPORTANCE OF CALCAR COMMINUTION AND SCREW LENGTH IN PROXIMAL HUMERUS FRACTURES TREATED WITH LOCKING PLATE FIXATION
    Raghava, Parthasarathy
    Thompson, Kevin J.
    Ponce, Brent A.
    Eberhardt, Alan W.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 651 - 652
  • [10] Use of Proximal Humerus Locking Plates for Fixation of Pediatric Femoral Neck Fractures: Technical Trick
    Gurnea, Taylor P.
    Nielsen, Ryan C.
    Althausen, Peter L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (09) : E312 - E315