APPLICATION OF A SYNTHETIC DIAMOND DETECTOR FOR THE MEASUREMENT OF RELATIVE DOSE DISTRIBUTIONS IN RADIOTHERAPY

被引:0
|
作者
Kazuchits, N. [1 ]
Rusetskyi, M. [1 ]
Shulenkov, A. [2 ]
Kukushkin, V. [3 ]
Martynov, S. [3 ]
Khrunov, V. [3 ]
Tuzov, J. [3 ]
Gatskevich, G. [4 ]
Kandybovich, D. [4 ]
机构
[1] Belarusian State Univ, Minsk 220030, BELARUS
[2] UP Minskii NII Radiomat, Minsk 220024, BELARUS
[3] Inst Phys & Tech Problems, Dubna 141980, Moscow Region, Russia
[4] NN Alexandrov Natl Canc Ctr Belarus, Minsk, BELARUS
来源
MEDICAL PHYSICS IN THE BALTIC STATES: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON MEDICAL PHYSICS | 2009年
关键词
Diamond; detector; sensitivity; gamma-rays; dose rate;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The suitability of a synthetic diamond for the measurement of relative dose distributions in selected radiotherapy applications was studied. The performance of the synthetic diamond detector was analyzed by comparison with that of natural diamond detector produced by a Physikalisch-Technische Werkstatten (Freiburg, Germany) (PTW). The synthetic diamond detector is concluded to be suitable for relative dose measurements, especially when high response and high spatial resolution are required.
引用
收藏
页码:76 / +
页数:2
相关论文
共 50 条
  • [31] Uncertainties in the measurement of relative doses in radiotherapy
    Bulinski, Krzysztof
    Kuszewski, Tomasz
    Wnuk, Katarzyna
    Braziewicz, Janusz
    Slosarek, Krzysztof
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (01): : 1 - 9
  • [32] CRITERIA FOR THE OPTIMIZATION OF GEOMETRICAL DOSE DISTRIBUTIONS IN RADIOTHERAPY
    WENDHAUSEN, H
    STRAHLENTHERAPIE, 1979, 155 (04) : 254 - 257
  • [33] ANON - COMPUTER CALCULATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY
    ROBERTSO.JS
    NUCLEAR APPLICATIONS, 1967, 3 (10): : 647 - &
  • [34] Requirements for synthetic diamond devices for radiotherapy dosimetry applications
    Guerrero, MJ
    Tromson, D
    Rebisz, M
    Mer, C
    Bazin, B
    Bergonzo, P
    DIAMOND AND RELATED MATERIALS, 2004, 13 (11-12) : 2046 - 2051
  • [35] Synthetic single crystal diamond diodes for radiotherapy dosimetry
    Almaviva, S.
    Marinelli, Marco
    Milani, E.
    Tucciarone, A.
    Verona-Rinati, G.
    Consorti, R.
    Petrucci, A.
    De Notaristefani, F.
    Ciancaglioni, I.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 594 (02): : 273 - 277
  • [36] Synthetic diamond X-ray dosimeter for radiotherapy
    Lansley, S. P.
    Betzel, G. T.
    Baluti, F.
    Reinisch, L.
    Meyer, J.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1658 - 1661
  • [37] Requirements for synthetic diamond devices for radiotherapy dosimetry applications
    Guerrero, M.J. (marie-josephine.guerrero@cea.fr), (Elsevier Ltd):
  • [38] Subsurface modification and relative optical density of synthetic diamond
    Ma, ZQ
    Zheng, YF
    Naramoto, H
    APPLIED SURFACE SCIENCE, 1997, 119 (3-4) : 181 - 184
  • [39] Measurement of stopping beam distributions in the PIBETA detector
    Frlez, E.
    Bychkov, M.
    Li, W.
    Pocanic, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (03): : 371 - 383
  • [40] Subsurface modification and relative optical density of synthetic diamond
    Xinjiang Univ, Urumqi, China
    Appl Surf Sci, 3-4 (181-184):