摘要
The suitability of a synthetic diamond for the measurement of relative dose distributions in selected radiotherapy applications was studied. The performance of the synthetic diamond detector was analyzed by comparison with that of natural diamond detector produced by a Physikalisch-Technische Werkstatten (Freiburg, Germany) (PTW). The synthetic diamond detector is concluded to be suitable for relative dose measurements, especially when high response and high spatial resolution are required.
引用
收藏
页码:76 / +
页数:2
相关论文
共 50 条
  • [1] APPLICATION OF A NATURAL DIAMOND DETECTOR FOR THE MEASUREMENT OF RELATIVE DOSE DISTRIBUTIONS IN RADIOTHERAPY
    VATNITSKY, S
    JARVINEN, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (01): : 173 - 184
  • [2] Application of polymer-gel dosimeter for evaluation of relative dose distributions in stereotactic radiotherapy
    Novotny, JJ
    Spevacek, V
    Dvorak, P
    Novotny, J
    Hrbacek, J
    Tintera, J
    Vymazal, J
    Cechak, T
    Michalek, J
    Vacik, J
    Liscak, R
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S51 - S51
  • [3] Determining the dose per pulse dependence of a commercial synthetic diamond detector
    O'Doherty, D.
    Cross, J.
    Plaistow, R.
    Fathi, K.
    Thomas, S. J.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S912 - S912
  • [4] High-performance oxygen terminated synthetic single crystal diamond detector for high gamma dose rate measurement
    Wang, Libin
    Zhang, Yiyun
    Wei, Xuecheng
    Xi, Shanxue
    Huang, Guangwei
    Li, Haijun
    Ma, Zhihai
    Song, Yushou
    Zhou, Chunzhi
    Yi, Xiaoyan
    Wang, Junxi
    Liu, Huilan
    Li, Jinmin
    RADIATION MEASUREMENTS, 2024, 177
  • [5] Application of a novel diamond detector for commissioning of FLASH radiotherapy electron beams
    Verona Rinati, Gianluca
    Felici, Giuseppe
    Galante, Federica
    Gasparini, Alessia
    Kranzer, Rafael
    Mariani, Giulia
    Pacitti, Matteo
    Prestopino, Giuseppe
    Schuller, Andreas
    Vanreusel, Verdi
    Verellen, Dirk
    Verona, Claudio
    Marinelli, Marco
    MEDICAL PHYSICS, 2022, 49 (08) : 5513 - 5522
  • [6] Measurement setup for verifying dose distributions of 106Ru eye-plaques with synthetic diamond and diode detectors
    Heilemann, G.
    Nesvacil, N.
    Blaickner, M.
    Georg, D.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S152 - S152
  • [7] Evaluation of a synthetic single-crystal diamond detector for relative dosimetry measurements on a CyberKnife™
    Chalkley, A.
    Heyes, G.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1035):
  • [8] EVALUATION OF A DIODE DETECTOR ARRAY FOR MEASUREMENT OF DYNAMIC WEDGE DOSE DISTRIBUTIONS
    LEAVITT, DD
    LARSSON, L
    MEDICAL PHYSICS, 1993, 20 (02) : 381 - 382
  • [9] Single crystal diamond detector for radiotherapy
    Schirru, F.
    Kisielewicz, K.
    Nowak, T.
    Marczewska, B.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (26)
  • [10] Response function measurement of a synthetic diamond radiation detector for 14 MeV neutrons
    Kaneko, Junichi
    Ikeda, Yujiro
    Nishitani, Takeo
    Katagiri, Masaki
    Review of Scientific Instruments, 1999, 70 (1 II): : 1100 - 1103