Predictive power management strategies for stand-alone hydrogen systems: Operational impact

被引:45
|
作者
Brka, Adel [1 ]
Al-Abdeli, Yasir M. [1 ]
Kothapalli, Ganesh [1 ]
机构
[1] Edith Cowan Univ, Sch Engn, 270 Joondalup Dr, Joondalup, WA 6027, Australia
关键词
Hydrogen; Predictive; Power management strategy; Renewables; Device intermittency; Optimisation; RENEWABLE ENERGY-SYSTEMS; PARTICLE SWARM OPTIMIZATION; OPTIMAL-DESIGN; TECHNOECONOMIC OPTIMIZATION; PERFORMANCE ANALYSIS; GENERATION SYSTEM; HYBRID; STORAGE; MODEL; CONVERSION;
D O I
10.1016/j.ijhydene.2016.03.085
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper compares the operational impacts of both predictive and reactive Power Management Strategies (P-PMS and R-PMS). The study is implemented for a stand-alone hybrid system based on wind turbines (WG), batteries (BAT) and hydrogen technology. The P-PMS uses real-time Neural Network (NN) predictions of wind speed and load demand to adjust the control set points affecting the switching of devices. The study also analyses the effects of using another intelligent technique, Particle Swarm Optimisation (PSO), for real-time optimisation of fuel cell operation. Genetic Algorithms (GA) are used to optimally size the hydrogen system. The methods employed include MATLAB simulations to implement the three intelligent techniques (GA, NN and PSO) and integration of experimentally derived fuel cell characteristics as well as highly dynamic electric load and wind speed profiles. The research presented in this study is an extension of an earlier work in which the concept of P-PMS was experimentally validated and the effects of some software and hardware related controlling parameters assessed. This paper however goes further by analysing the impact of using P-PMS on the economic and operational characteristics of stand-alone hydrogen systems by benchmarking it against an R-PMS. Results reveal that a hybrid system operating under a P-PMS outperforms that with an R-PMS in terms of cost, renewables penetration and environmental footprint. In addition, this study showed that P-PMS can help mitigate the impact of the transient response of the backup components (fuel cell and electrolyser) on the system sizing and operation. However, these merits are realised only if a particularly high reliability of load satisfaction is required. Results also show that a P-PMS highly depends on the accuracy of the employed (NN) prediction tool. The proposed predictive strategies are proven to be better than other solutions that exist in literature in terms of reducing the cost. Copyright (C) 2016, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:6685 / 6698
页数:14
相关论文
共 50 条
  • [1] Predictive power management strategies for stand-alone hydrogen systems: Lab-scale validation
    Brka, Adel
    Kothapalli, Ganesh
    Al-Abdeli, Yasir M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (32) : 9907 - 9916
  • [2] Power management strategies for a stand-alone power system using renewable energy sources and hydrogen storage
    Ipsakis, Dimitris
    Voutetakis, Spyros
    Seferlis, Panos
    Stergiopoulos, Fotis
    Elmasides, Costas
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (16) : 7081 - 7095
  • [3] The effect of the hysteresis band on power management strategies in a stand-alone power system
    Ipsakis, Dimitris
    Voutetakis, Spyros
    Seferlis, Panos
    Stergiopoulos, Fotis
    Papadopoulou, Simira
    Elmasides, Costas
    ENERGY, 2008, 33 (10) : 1537 - 1550
  • [4] Evaluation of different operating strategies in small stand-alone power systems
    Billinton, B
    Billinton, R
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (03) : 654 - 660
  • [5] Analysis of the barriers for the hydrogen energy technology in stand-alone power systems
    Tsoutsos, T.D.
    Zoulias, E.I.
    Lymberopoulos, N.
    Glöckner, R.
    Wind Engineering, 2004, 28 (05) : 615 - 620
  • [6] Optimization of control strategies for stand-alone renewable energy systems with hydrogen storage
    Dufo-Lopez, Rodolfo
    Bernal-Agustin, Jose L.
    Contreras, Javier
    RENEWABLE ENERGY, 2007, 32 (07) : 1102 - 1126
  • [7] Direct coupling photovoltaic power regulator for stand-alone power systems with hydrogen generation
    Garrigos, A.
    Blanes, J. M.
    Rubiato, J.
    Avila, E.
    Garcia, C. G.
    Lizan, J. L.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (19) : 10127 - 10137
  • [8] Hybrid Stand-alone Power Systems with Hydrogen Energy Storage for Isolated Communities
    Gargoom, Ameen
    Haruni, Abu Mohammad Osman
    Haque, Md Enamul
    Negnevitsky, Michael
    2010 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: SMART SOLUTIONS FOR A CHANGING WORLD, 2010,
  • [9] AN OPTIMUM LOAD MANAGEMENT STRATEGY FOR STAND-ALONE PHOTOVOLTAIC POWER-SYSTEMS
    GROUMPOS, PP
    PAPEGEORGIOU, G
    SOLAR ENERGY, 1991, 46 (02) : 121 - 128
  • [10] Hybrid energy storage systems and control strategies for stand-alone renewable energy power systems
    Chong, Lee Wai
    Wong, Yee Wan
    Rajkumar, Rajprasad Kumar
    Rajkumar, Rajpartiban Kumar
    Isa, Dino
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 66 : 174 - 189