Predictive power management strategies for stand-alone hydrogen systems: Operational impact

被引:45
|
作者
Brka, Adel [1 ]
Al-Abdeli, Yasir M. [1 ]
Kothapalli, Ganesh [1 ]
机构
[1] Edith Cowan Univ, Sch Engn, 270 Joondalup Dr, Joondalup, WA 6027, Australia
关键词
Hydrogen; Predictive; Power management strategy; Renewables; Device intermittency; Optimisation; RENEWABLE ENERGY-SYSTEMS; PARTICLE SWARM OPTIMIZATION; OPTIMAL-DESIGN; TECHNOECONOMIC OPTIMIZATION; PERFORMANCE ANALYSIS; GENERATION SYSTEM; HYBRID; STORAGE; MODEL; CONVERSION;
D O I
10.1016/j.ijhydene.2016.03.085
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper compares the operational impacts of both predictive and reactive Power Management Strategies (P-PMS and R-PMS). The study is implemented for a stand-alone hybrid system based on wind turbines (WG), batteries (BAT) and hydrogen technology. The P-PMS uses real-time Neural Network (NN) predictions of wind speed and load demand to adjust the control set points affecting the switching of devices. The study also analyses the effects of using another intelligent technique, Particle Swarm Optimisation (PSO), for real-time optimisation of fuel cell operation. Genetic Algorithms (GA) are used to optimally size the hydrogen system. The methods employed include MATLAB simulations to implement the three intelligent techniques (GA, NN and PSO) and integration of experimentally derived fuel cell characteristics as well as highly dynamic electric load and wind speed profiles. The research presented in this study is an extension of an earlier work in which the concept of P-PMS was experimentally validated and the effects of some software and hardware related controlling parameters assessed. This paper however goes further by analysing the impact of using P-PMS on the economic and operational characteristics of stand-alone hydrogen systems by benchmarking it against an R-PMS. Results reveal that a hybrid system operating under a P-PMS outperforms that with an R-PMS in terms of cost, renewables penetration and environmental footprint. In addition, this study showed that P-PMS can help mitigate the impact of the transient response of the backup components (fuel cell and electrolyser) on the system sizing and operation. However, these merits are realised only if a particularly high reliability of load satisfaction is required. Results also show that a P-PMS highly depends on the accuracy of the employed (NN) prediction tool. The proposed predictive strategies are proven to be better than other solutions that exist in literature in terms of reducing the cost. Copyright (C) 2016, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:6685 / 6698
页数:14
相关论文
共 50 条
  • [31] Controlling a stand-alone power system
    Marinescu, C.
    Ion, C.
    Serban, I.
    Clotea, L.
    Marinescu, D.
    2006 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2006, : 525 - +
  • [32] A Novel Power Management Control Strategy for a Renewable Stand-Alone Power System
    Haruni, A. M. O.
    Negnevitsky, M.
    Haque, M. Enamul
    Gargoom, A.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [33] A Novel Power Management Control Strategy for Stand-alone Photovoltaic Power System
    Liao, Zhiling
    Ruan, Xinbo
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1175 - +
  • [34] Robust Power Management Control for Stand-Alone Hybrid Power Generation System
    Kamal, Elkhatib
    Adouane, Lounis
    Aitouche, Abdel
    Mohammed, Walaa
    13TH EUROPEAN WORKSHOP ON ADVANCED CONTROL AND DIAGNOSIS (ACD 2016), 2017, 783
  • [35] Embodied Energy and Environmental Impact of Large-Power Stand-Alone Photovoltaic Irrigation Systems
    Todde, Giuseppe
    Murgia, Lelia
    Carrelo, Isaac
    Hogan, Rita
    Pazzona, Antonio
    Ledda, Luigi
    Narvarte, Luis
    ENERGIES, 2018, 11 (08)
  • [36] Flywheel-based AC cache power for stand-alone power systems
    Cheng, Miao-Miao
    Kato, Shuhei
    Sumitani, Hideo
    Shimada, Ryuichi
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2013, 8 (03) : 290 - 296
  • [37] Modeling of a Stand-Alone Microgrid Based on Solar-Hydrogen Energy Systems for the Design of Energy Management Systems
    Hou, Zhipeng
    Chen, Fengxiang
    Guo, Yafeng
    Mo, Tiande
    Li, Yu
    Pei, Fenglai
    PROCEEDINGS OF THE 10TH HYDROGEN TECHNOLOGY CONVENTION, VOL 3, WHTC 2023, 2024, 395 : 150 - 158
  • [38] Development of stand-alone photovoltaic systems
    Glasnovic, Zvonimir
    Urli, Natko
    Etlinger, Bozidar
    ENERGY AND THE ENVIRONMENT 2002, VOL II, 2002, : 255 - 263
  • [39] INTEGRATED VS STAND-ALONE SYSTEMS
    KLINE, N
    LIBRARY SOFTWARE REVIEW, 1986, 5 (04): : 219 - 223
  • [40] SMALL STAND-ALONE WINDPOWER SYSTEMS
    FRAENKEL, PL
    NATURAL RESOURCES FORUM, 1990, 14 (01) : 49 - 57