Predictive power management strategies for stand-alone hydrogen systems: Lab-scale validation

被引:41
|
作者
Brka, Adel [1 ]
Kothapalli, Ganesh [1 ]
Al-Abdeli, Yasir M. [1 ]
机构
[1] Edith Cowan Univ, Sch Engn, Joondalup, WA 6027, Australia
关键词
Intelligent; Predictive; Power management strategy; Experiments; Real-time; Hydrogen; DATA-ACQUISITION SYSTEM; HYBRID ENERGY SYSTEM; SITE WATER PRODUCTION; OF-CHARGE ESTIMATION; RENEWABLE ENERGY; OPERATIONAL CHARACTERISTICS; PERFORMANCE ASSESSMENT; GENERATION SYSTEMS; SOLAR-RADIATION; OPTIMAL-DESIGN;
D O I
10.1016/j.ijhydene.2015.06.081
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Power Management Strategies (PMSs) to control stand-alone energy systems affect the reliability of meeting load demand as well as the cyclic operation of various subsystems. The hybridisation of sources through the integration of hydrogen fuel cells with energy storage means optimising the PMS should be "intelligently" done unless relying on rule-based PMSs which are simplistic to use but subject to lack of optimisation. This paper presents the methodology and validation of a lab-scale (desktop) energy system controlled by a predictive PMS. Validation of the intelligently based PMS can be done in the lab-scale before (costly) full deployment in the field, but experiments to support this have not been reported in relation to hydrogen systems. The experimentally tested hybrid energy system consists of an emulated renewable power source which can represent solar-PV and/or wind generators, battery bank and PEM fuel cell integrated with metal hydride storage. Experimental testing as well as the use of real-time predictions using Neural Networks is utilised. The effects of several control parameters which are either hardware dependant or affect the predictive algorithm are investigated with system performance, under the predictive PMS, benchmarked against a rule-based PMS. The results reveal that a predictive PMS is impacted by the prediction horizon used to forecast the availability of renewables or load, the decision time interval used for updating the PMS as well as time lags resulting from hardware sensors used to convey system status to the decision algorithm responsible for updating the PMS. The maximum thresholds of the above mentioned control parameters are 120, 15 and 3 s, respectively. Beyond these limits, the ability of the predictive PMS to effectively control the system degrades significantly. This study demonstrates the feasibility of using real-time predictions of renewable resources and load demand to optimise a PMS in a stand-alone energy system and experimentally validates this, which has not been previously reported. Copyright (C) 2015, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:9907 / 9916
页数:10
相关论文
共 50 条
  • [1] Predictive power management strategies for stand-alone hydrogen systems: Operational impact
    Brka, Adel
    Al-Abdeli, Yasir M.
    Kothapalli, Ganesh
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (16) : 6685 - 6698
  • [2] Power management strategies for a stand-alone power system using renewable energy sources and hydrogen storage
    Ipsakis, Dimitris
    Voutetakis, Spyros
    Seferlis, Panos
    Stergiopoulos, Fotis
    Elmasides, Costas
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (16) : 7081 - 7095
  • [3] The effect of the hysteresis band on power management strategies in a stand-alone power system
    Ipsakis, Dimitris
    Voutetakis, Spyros
    Seferlis, Panos
    Stergiopoulos, Fotis
    Papadopoulou, Simira
    Elmasides, Costas
    ENERGY, 2008, 33 (10) : 1537 - 1550
  • [4] Evaluation of different operating strategies in small stand-alone power systems
    Billinton, B
    Billinton, R
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (03) : 654 - 660
  • [5] Analysis of the barriers for the hydrogen energy technology in stand-alone power systems
    Tsoutsos, T.D.
    Zoulias, E.I.
    Lymberopoulos, N.
    Glöckner, R.
    Wind Engineering, 2004, 28 (05) : 615 - 620
  • [6] Optimization of control strategies for stand-alone renewable energy systems with hydrogen storage
    Dufo-Lopez, Rodolfo
    Bernal-Agustin, Jose L.
    Contreras, Javier
    RENEWABLE ENERGY, 2007, 32 (07) : 1102 - 1126
  • [7] Direct coupling photovoltaic power regulator for stand-alone power systems with hydrogen generation
    Garrigos, A.
    Blanes, J. M.
    Rubiato, J.
    Avila, E.
    Garcia, C. G.
    Lizan, J. L.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (19) : 10127 - 10137
  • [8] Hybrid Stand-alone Power Systems with Hydrogen Energy Storage for Isolated Communities
    Gargoom, Ameen
    Haruni, Abu Mohammad Osman
    Haque, Md Enamul
    Negnevitsky, Michael
    2010 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION: SMART SOLUTIONS FOR A CHANGING WORLD, 2010,
  • [9] AN OPTIMUM LOAD MANAGEMENT STRATEGY FOR STAND-ALONE PHOTOVOLTAIC POWER-SYSTEMS
    GROUMPOS, PP
    PAPEGEORGIOU, G
    SOLAR ENERGY, 1991, 46 (02) : 121 - 128
  • [10] Hybrid energy storage systems and control strategies for stand-alone renewable energy power systems
    Chong, Lee Wai
    Wong, Yee Wan
    Rajkumar, Rajprasad Kumar
    Rajkumar, Rajpartiban Kumar
    Isa, Dino