Predictive power management strategies for stand-alone hydrogen systems: Lab-scale validation

被引:41
|
作者
Brka, Adel [1 ]
Kothapalli, Ganesh [1 ]
Al-Abdeli, Yasir M. [1 ]
机构
[1] Edith Cowan Univ, Sch Engn, Joondalup, WA 6027, Australia
关键词
Intelligent; Predictive; Power management strategy; Experiments; Real-time; Hydrogen; DATA-ACQUISITION SYSTEM; HYBRID ENERGY SYSTEM; SITE WATER PRODUCTION; OF-CHARGE ESTIMATION; RENEWABLE ENERGY; OPERATIONAL CHARACTERISTICS; PERFORMANCE ASSESSMENT; GENERATION SYSTEMS; SOLAR-RADIATION; OPTIMAL-DESIGN;
D O I
10.1016/j.ijhydene.2015.06.081
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Power Management Strategies (PMSs) to control stand-alone energy systems affect the reliability of meeting load demand as well as the cyclic operation of various subsystems. The hybridisation of sources through the integration of hydrogen fuel cells with energy storage means optimising the PMS should be "intelligently" done unless relying on rule-based PMSs which are simplistic to use but subject to lack of optimisation. This paper presents the methodology and validation of a lab-scale (desktop) energy system controlled by a predictive PMS. Validation of the intelligently based PMS can be done in the lab-scale before (costly) full deployment in the field, but experiments to support this have not been reported in relation to hydrogen systems. The experimentally tested hybrid energy system consists of an emulated renewable power source which can represent solar-PV and/or wind generators, battery bank and PEM fuel cell integrated with metal hydride storage. Experimental testing as well as the use of real-time predictions using Neural Networks is utilised. The effects of several control parameters which are either hardware dependant or affect the predictive algorithm are investigated with system performance, under the predictive PMS, benchmarked against a rule-based PMS. The results reveal that a predictive PMS is impacted by the prediction horizon used to forecast the availability of renewables or load, the decision time interval used for updating the PMS as well as time lags resulting from hardware sensors used to convey system status to the decision algorithm responsible for updating the PMS. The maximum thresholds of the above mentioned control parameters are 120, 15 and 3 s, respectively. Beyond these limits, the ability of the predictive PMS to effectively control the system degrades significantly. This study demonstrates the feasibility of using real-time predictions of renewable resources and load demand to optimise a PMS in a stand-alone energy system and experimentally validates this, which has not been previously reported. Copyright (C) 2015, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:9907 / 9916
页数:10
相关论文
共 50 条
  • [41] Passive MPPT method for stand-alone wind power generation systems
    Bai Y.
    Kou B.
    Chan C.C.
    Kou, Baoquan (koubq@hit.edu.cn), 1600, Central South University of Technology (48): : 370 - 380
  • [42] A design methodology of stand-alone photovoltaic power systems for rural electrification
    Ghaib, Karim
    Ben-Fares, Fatima-Zahrae
    ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 1127 - 1141
  • [43] Multiport Switch based MPPT for stand-alone Photovoltaic Power Systems
    Prakash, Kaipakam
    Vejju, Pradeep
    Reddy, B. Venugopal
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [44] OPTIMAL SIZING OF STAND-ALONE PHOTOVOLTAIC SOLAR POWER-SYSTEMS
    GORDON, JM
    SOLAR CELLS, 1987, 20 (04): : 295 - 313
  • [45] Stand-alone hybrid energy systems for remote area power generation
    Razmjoo, Armin
    Shirmohammadi, Reza
    Davarpanah, Afshin
    Pourfayaz, Fathollah
    Aslani, Alireza
    ENERGY REPORTS, 2019, 5 : 231 - 241
  • [46] AN OPTIMAL SIZING METHOD FOR STAND-ALONE PHOTOVOLTAIC POWER-SYSTEMS
    GROUMPOS, PP
    PAPAGEORGIOU, G
    SOLAR ENERGY, 1987, 38 (05) : 341 - 351
  • [47] A systems approach for sizing a stand-alone residential PEMFC power system
    Selamogullari, Ugur S.
    Willemain, Thomas R.
    Torrey, David A.
    JOURNAL OF POWER SOURCES, 2007, 171 (02) : 802 - 810
  • [48] Hybrid Stand-alone Power Supply Systems for the Arctic Polar Stations
    A. V. Frolov
    A. S. Grigoriev
    A. V. Korolev
    O. G. Losev
    D. A. Mel’nik
    Russian Meteorology and Hydrology, 2019, 44 : 305 - 310
  • [49] Hybrid Stand-alone Power Supply Systems for the Arctic Polar Stations
    Frolov, A. V.
    Grigoriev, A. S.
    Korolev, A. V.
    Losev, O. G.
    Mel'nik, D. A.
    RUSSIAN METEOROLOGY AND HYDROLOGY, 2019, 44 (04) : 305 - 310
  • [50] Sizing of a stand-alone microgrid considering electric power, cooling/heating and hydrogen
    Li, Bei
    Roche, Robin
    Miraoui, Abdellatif
    2017 IEEE MANCHESTER POWERTECH, 2017,