A Monte Carlo-based IMRT plan re-calculator

被引:0
|
作者
Zakarian, K [1 ]
Alaly, J [1 ]
Low, D [1 ]
Wood, R [1 ]
Zhang, L [1 ]
Deasy, J [1 ]
机构
[1] WUSTL, St Louis, MO USA
关键词
D O I
10.1118/1.1997798
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: IMRT QA currently is currently a time consuming activity. We hypothesize that IMRT QA labor would significantly decrease if a software tool were available which conveniently re‐checked IMRT treatment plans by independently re‐computing the expected dose distribution based on the leaf‐instructions generated by the treatment planning system. Such a system should have the capability to make detailed comparisons with the original treatment plan. Method and Materials: Our research treatment planning system CERR (Computational Environment for Radiotherapy Research) was modified and extended to include the capability of recomputing dose based on leaf‐sequences received via DICOM. Three dose computation algorithms have been implemented: (1) a simple pencil beam model which corrects for changes in central axis attenuation, but includes realistic scatter tails, (2) the Monte Carlo code VMC++, and (3) the open source Monte Carlo code DPM (dose planning method). GUI tools were developed to allow for side‐by‐side dose comparisons and comparative profile dose plots, in addition to DVH comparisons. Initial tests were performed using data generated via the Varian Helios planning system. Comparisons were made beam‐by‐beam in a simplified QA geometry as well as for total dose. Results: Initial results indicate reasonable agreement between the Helios planning system dose distributions and the pencil beam method. Differences with Monte Carlo results were greater, but energy spectral effects have not yet been added to the model. Conclusion: CERR provides a powerful and convenient environment to develop an IMRT plan re‐calculator. Initial results indicate the basic correctness of data being used for the dose recalculation. We expect to fully develop this system as a helpful tool for IMRT QA. Conflict of Interest: This research was supported by a grant from Sun Nuclear, Inc. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1979 / 1979
页数:1
相关论文
共 50 条
  • [1] Monte Carlo-based QA for IMRT of head and neck cancers
    Tang, F.
    Sham, J.
    Ma, C-M
    Li, J-S
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [2] A prototype Monte Carlo-Based IMRT treatment planning research system
    Deasy, J
    Lee, E
    Kawrakow, I
    Zakarian, C
    MEDICAL PHYSICS, 2002, 29 (06) : 1254 - 1254
  • [3] Fast online Monte Carlo-based IMRT planning for the MRI linear accelerator
    Bol, G. H.
    Hissoiny, S.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05): : 1375 - 1385
  • [4] The influence of air cavities within the PTV on Monte Carlo-based IMRT optimization
    De Smedt, Bart
    Vanderstraeten, Barbara
    Reynaert, Nick
    De Gersem, Werner
    De Neve, Wilfried
    Thierens, Hubert
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [5] A hybrid dose evaluation method for rapid Monte Carlo-based IMRT optimization
    Siebers, J.
    Kawrakow, I.
    MEDICAL PHYSICS, 2006, 33 (06) : 2207 - 2207
  • [6] Automation of Monte Carlo-based treatment plan verification for proton therapy
    Kaluarachchi, Maduka
    Moskvin, Vadim
    Pirlepesov, Fakhriddin
    Wilson, Lydia J.
    Xie, Fang
    Faught, Austin M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (08): : 131 - 138
  • [7] A Monte Carlo-based procedure for independent monitor unit calculation in IMRT treatment plans
    Pisaturo, O.
    Moeckli, R.
    Mirimanoff, R-O
    Bochud, F. O.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (13): : 4299 - 4310
  • [8] GPU-Monte Carlo Based Fast IMRT Plan Optimization
    Li, Y.
    Tian, Z.
    Shi, F.
    Jiang, S.
    Jia, X.
    MEDICAL PHYSICS, 2014, 41 (06) : 567 - 567
  • [9] Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculation
    Tyagi, Neelam
    Moran, Jean M.
    Litzenberg, Dale W.
    Bielajew, Alex F.
    Fraass, Benedick A.
    Chetty, Indrin J.
    MEDICAL PHYSICS, 2007, 34 (02) : 651 - 663
  • [10] Monte Carlo-based Inverse Treatment Plan Optimization for Intensity Modulated Proton Therapy
    Li, Y.
    Tian, Z.
    Song, T.
    Wu, Z.
    Liu, Y.
    Jiang, S. B.
    Jia, X.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 475 - 478